Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients - A prospective study with 115 examinations

被引:199
作者
Sommer, Torsten
Naehle, Claas P.
Yang, Alexander
Zeijlemaker, Volkert
Hackenbroch, Matthias
Schmiedel, Alexandra
Meyer, Carsten
Strach, Katharina
Skowasch, Dirk
Vahlhaus, Christian
Litt, Harold
Schild, Hans
机构
[1] Univ Bonn, Dept Radiol, Cardiovasc Imaging Sect, D-53127 Bonn, Germany
[2] Univ Bonn, Dept Cardiol, D-53127 Bonn, Germany
[3] Medtron Bakker Res Ctr, Maastricht, Netherlands
[4] Hosp Univ Muenster, Dept Cardiol & Angiol, Munster, Germany
[5] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
关键词
magnetic resonance imaging; pacemakers; safety; imaging;
D O I
10.1161/CIRCULATIONAHA.105.597013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The purpose of the present study was to evaluate a strategy for safe performance of extrathoracic magnetic resonance imaging (MRI) in non-pacemaker-dependent patients with cardiac pacemakers. Methods and Results-Inclusion criteria were presence of a cardiac pacemaker and urgent clinical need for an MRI examination. Pacemaker-dependent patients and those requiring examinations of the thoracic region were excluded. The study group consisted of 82 pacemaker patients who underwent a total of 115 MRI examinations at 1.5T. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 1.5 W/kg. All pacemakers were reprogrammed before MRI: If heart rate was < 60 bpm, the asynchronous mode was programmed to avoid magnetic resonance (MR)-induced inhibition; if heart rate was > 60 bpm, sense-only mode was used to avoid MR-induced competitive pacing and potential proarrhythmia. Patients were monitored with ECG and pulse oximetry. All pacemakers were interrogated immediately before and after the MRI examination and after 3 months, including measurement of pacing capture threshold (PCT) and serum troponin I levels. All MR examinations were completed safely. Inhibition of pacemaker output or induction of arrhythmias was not observed. PCT increased significantly from pre- to post-MRI (P = 0.017). In 2 of 195 leads, an increase in PCT was only detected at follow-up. In 4 of 114 examinations, troponin increased from a normal baseline value to above normal after MRI, and in 1 case (troponin pre-MRI 0.02 ng/mL, post-MRI 0.16 ng/mL), this increase was associated with a significant increase in PCT. Conclusions-Extrathoracic MRI of non-pacemaker-dependent patients can be performed with an acceptable risk-benefit ratio under controlled conditions and by taking both MR-and pacemaker-related precautions.
引用
收藏
页码:1285 / 1292
页数:8
相关论文
共 26 条
[21]   Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe - In vitro and in vivo assessment of safety and function at 1.5 T [J].
Roguin, A ;
Zviman, MM ;
Meininger, GR ;
Rodrigues, ER ;
Dickfeld, TM ;
Bluemke, DA ;
Lardo, A ;
Berger, RD ;
Calkins, H ;
Halperin, HR .
CIRCULATION, 2004, 110 (05) :475-482
[22]   Concerns about sources of electromagnetic interference in patients with pacemakers [J].
Sakakibara, Y ;
Mitsui, T .
JAPANESE HEART JOURNAL, 1999, 40 (06) :737-743
[23]   Virtual electrode theory explains pacing threshold increase caused by cardiac tissue damage [J].
Sambelashvili, AT ;
Nikolski, VP ;
Efimov, IR .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 286 (06) :H2183-H2194
[24]   Magnetic resonance imaging of the brain in patients with cardiac pace makers.: In-vitro- and in-vivo-evaluation at 1.5 Tesla [J].
Schmiedel, A ;
Hackenbroch, M ;
Yang, A ;
Nähle, CP ;
Skowasch, D ;
Meyer, C ;
Schimpf, R ;
Schild, H ;
Sommer, T .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (05) :731-744
[25]   MR imaging and cardiac pacemakers:: In vitro evaluation and in vivo studies in 51 patients at 0.5 T [J].
Sommer, T ;
Vahlhaus, C ;
Lauck, G ;
Von Smekal, A ;
Reinke, M ;
Hofer, U ;
Block, W ;
Träber, F ;
Schneider, C ;
Gieseke, J ;
Jung, W ;
Schild, H .
RADIOLOGY, 2000, 215 (03) :869-879
[26]   Interference with cardiac pacemakers by magnetic resonance imaging:: Are there irreversible changes at 0.5 Tesla? [J].
Vahlhaus, C ;
Sommer, T ;
Lewalter, T ;
Schimpf, R ;
Schumacher, B ;
Jung, W ;
Lüderitz, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (04) :489-495