Investigation of aerosol based emission of MEA due to sulphuric acid aerosol and soot in a Post Combustion CO2 Capture process

被引:87
作者
Khakharia, Purvil [1 ]
Brachert, Leonie [2 ]
Mertens, Jan [3 ]
Huizinga, Arjen [1 ]
Schallert, Bernd [4 ]
Schaber, Karlheinz [2 ]
Vlugt, Thijs J. H. [5 ]
Goetheer, Earl [1 ]
机构
[1] TNO, NL-2628 CA Delft, Netherlands
[2] Karlsruhe Inst Technol, Inst Tech Thermodynam & Kaltetech, D-76131 Karlsruhe, Germany
[3] Laborelec, B-1630 Linkebeek, Belgium
[4] E ON New Build & Technol GmbH, D-45896 Gelsenkirchen, Germany
[5] Delft Univ Technol, NL-2628 CA Delft, Netherlands
关键词
Post Combustion CO2 Capture; Emission; Aerosols; Soot; Sulphuric acid; CARBON CAPTURE; PERFORMANCE;
D O I
10.1016/j.ijggc.2013.08.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The prevention of emissions of amine species is of high importance for the overall sustainability and performance of Post Combustion CO2 Capture facilities. There is a clear understanding of amine emissions based on volatility in the treated flue gas. Emission via aerosols from Post Combustion CO2 Capture facilities has only been pointed out recently. Thus, there is little knowledge about emission via aerosols in contrast to emission based on volatility. It has been found that flue gas quality plays an important role for emissions caused by aerosols formation. In this work, we study the experimental assessment of the impact of flue gas quality on the level of monoethanolamine (MEA) emission via aerosols. In a dedicated test rig, effects of the flue gas components such as sulphuric acid aerosols and extremely fine particles like soot has been studied. An aerosol generator capable of producing controlled amounts of soot and dosing sulphuric acid aerosol to a mobile CO2 capture mini-plant was used as a test equipment for this study. Soot particle number concentration were in the range of 10(4)-10(8) per cm(3). The particle number concentration for different amount of H2SO4 aerosols were in the order of 108 per cm(3). Amine emissions up to 4.3 ppmv (12 mg/N m(3) for MEA) is considered to be as an upper limit for the design of a Post Combustion CO2 Capture plant. MEA emissions in the presence of soot particles were in the range of 100-200 mg/N m(3) which is 2-4 times higher than baseline vapour based emissions of about 45 mg/N m(3). The expected particle size of H2SO4 aerosols is well below 100 nm, while the corresponding mass concentration range is between 1 and 5 mg/m(3). The MEA emissions observed due to H2SO4 aerosols were in the range of 600-1100 mg/N m(3). Moreover, parametric tests have shown that besides flue gas quality, the absorber temperature profile and the presence of CO2 in the flue gas are pre-requisite for aerosol emissions. It is evident that the observed level of emissions in this study are unacceptable. Therefore, it is imperative that fundamental know-how about aerosol formation and reduction is generated in order to design appropriate counter measures. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 32 条
  • [1] CO2 capture from power plants.: Part I.: A parametric study of the technical-performance based on monoethanolamine
    Abu-Zahra, Mohammad R. M.
    Schneiders, Leon H. J.
    Niederer, John P. M.
    Feron, Paul H. M.
    Versteeg, Geert F.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (01) : 37 - 46
  • [2] Process configuration studies of the amine capture process for coal-fired power plants
    Ahn, Hyungwoong
    Luberti, Mauro
    Liu, Zhengyi
    Brandani, Stefano
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2013, 16 : 29 - 40
  • [3] [Anonymous], CARB DIOX CAPT STOR
  • [4] Facing the Sulfuric Acid Aerosol Problem in Flue Gas Cleaning: Pilot Plant Experiments and Simulation
    Brachert, L.
    Kochenburger, T.
    Schaber, K.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (10) : 1083 - 1091
  • [5] Studies of the Fate of Sulfur Trioxide in Coal-Fired Utility Boilers Based on Modified Selected Condensation Methods
    Cao, Yan
    Zhou, Hongcang
    Jiang, Wu
    Chen, Chien-Wei
    Pan, We-Ping
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (09) : 3429 - 3434
  • [6] Cheng Y.-S., 2011, Aerosol measurement, P381, DOI DOI 10.1002/9781118001684.CH17
  • [7] CO2 Technology Centre Mongstad - Design, Functionality and Emissions of the Amine Plant
    de Koeijer, Gelein
    Enge, Yngvil
    Sanden, Knut
    Graff, Oscar Fr.
    Falk-Pedersen, Olav
    Amundsen, Tore
    Overa, Sverre
    [J]. 10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1207 - 1213
  • [8] Frank T. C., 2008, PERRYS CHEM ENG HDB
  • [9] Degradation of aqueous piperazine in carbon dioxide capture
    Freeman, Stephanie A.
    Davis, Jason
    Rochelle, Gary T.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2010, 4 (05) : 756 - 761
  • [10] Aerosol formation by heterogeneous nucleation in wet scrubbing processes
    Gretscher, H
    Schaber, K
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1999, 38 (4-6) : 541 - 548