Evaluation of the Delta4 phantom for IMRT and VMAT verification

被引:200
作者
Bedford, James L. [1 ]
Lee, Young K.
Wai, Philip
South, Christopher P.
Warrington, Alan P.
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
关键词
MODULATED ARC THERAPY; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; GUIDANCE; CANCER;
D O I
10.1088/0031-9155/54/9/N04
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Delta(4) diode array phantom (Scandidos, Uppsala, Sweden) was evaluated for verification of segmental intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) on an Elekta linear accelerator (Crawley UK). The device was tested for angular sensitivity by irradiating it from 36 different gantry angles, and the responses of the device to various step-and-shoot segment doses and dose rates were evaluated using an ionization chamber as a comparison. The phantom was then compared with ionization chamber and film results for two prostate and pelvic nodes IMRT plans, two head and neck IMRT plans and two lung VMAT plans. These plans were calculated using Pinnacle(3) (Philips Radiation Oncology Systems, Madison, WI). The uniformity of angular response was better than 0.5% over the range of gantry angles. The uniformity of response of the Delta(4) to different segment monitor units and dose rates was better than 0.5%. The assessment of the IMRT and VMAT plans showed that the Delta(4) measured a dose within 2.5% of the ionization chamber, and compared to film recorded a slightly larger region (range -2% to +7%) agreeing with the planned dose to within 3% and 3 mm. The Delta(4) is a complex device and requires careful benchmarking, but following the successful completion of these measurements, the Delta(4) has been introduced into clinical use.
引用
收藏
页码:N167 / N176
页数:10
相关论文
共 9 条
[1]   Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement [J].
Adams, EJ ;
Convery, DJ ;
Cosgrove, VP ;
McNair, HA ;
Staffurth, JN ;
Vaarkamp, J ;
Nutting, CM ;
Warrington, AP ;
Webb, S ;
Balyckyi, J ;
Dearnaley, DP .
RADIOTHERAPY AND ONCOLOGY, 2004, 70 (01) :1-10
[2]  
BEDFORD J, 2008, P IPEM BIENN RAD M B, P122
[3]   Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study [J].
Bedford, James L. ;
Hansen, Vibeke Nordmark ;
Mcnair, Helen A. ;
Aitken, Alexandra H. ;
Brock, Juliet E. C. ;
Warrington, Alan P. ;
Brada, Michael .
ACTA ONCOLOGICA, 2008, 47 (07) :1438-1443
[4]  
Bedford James L, 2004, J Appl Clin Med Phys, V5, P1, DOI 10.1120/jacmp.2020.25271
[5]   COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) [J].
Bedford, James L. ;
Warrington, Alan P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :537-545
[6]   Commissioning and quality assurance-of the Pinnacle3 radiotherapy treatment planning system for external beam photons [J].
Bedford, JL ;
Childs, PJ ;
Hansen, VN ;
Mosleh-Shirazi, MA ;
Verhaegen, F ;
Warrington, AP .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (903) :163-176
[7]   Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee [J].
Ezzell, GA ;
Galvin, JM ;
Low, D ;
Palta, JR ;
Rosen, I ;
Sharpe, MB ;
Xia, P ;
Xiao, Y ;
Xing, L ;
Yu, CX .
MEDICAL PHYSICS, 2003, 30 (08) :2089-2115
[8]   Quality assurance of the dose delivered by small radiation segments [J].
Hansen, VN ;
Evans, PM ;
Budgell, GJ ;
Mott, JHL ;
Williams, PC ;
Brugmans, MJP ;
Wittkamper, FW ;
Mijnheer, BJ ;
Brown, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09) :2665-2675
[9]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661