Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

被引:20
作者
Jang, Jinhee [1 ]
Schmitt, Peter [2 ]
Kim, Bom-yi [1 ]
Choi, Hyun Seok [1 ]
Jung, So-Lyung [1 ]
Ahn, Kook-Jin [1 ]
Kim, Inseong [3 ]
Paek, Munyoung [3 ]
Kim, Bum-soo [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, Seoul 137701, South Korea
[2] Siemens AG, Healthcare Sect, Erlangen, Germany
[3] Siemens AG, Healthcare, Seoul, South Korea
关键词
Magnetic resonance angiography; Non-contrast enhanced; Time resolved; Variable flip angle; Dural arteriovenous fistula; DIGITAL-SUBTRACTION-ANGIOGRAPHY; INTRACRANIAL HEMORRHAGE; MALFORMATIONS; TRANSIENT; CLASSIFICATION; SIGNAL; FLOW; 3T;
D O I
10.1007/s00234-014-1336-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 26 条
[1]   Non-Contrast-Enhanced Four-Dimensional (4D) Intracranial MR Angiography: A Feasibility Study [J].
Bi, Xiaoming ;
Weale, Peter ;
Schmitt, Peter ;
Zuehlsdorff, Sven ;
Jerecic, Renate .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :835-841
[2]   A PROPOSED CLASSIFICATION FOR SPINAL AND CRANIAL DURAL ARTERIOVENOUS FISTULOUS MALFORMATIONS AND IMPLICATIONS FOR TREATMENT [J].
BORDEN, JA ;
WU, JK ;
SHUCART, WA .
JOURNAL OF NEUROSURGERY, 1995, 82 (02) :166-179
[3]   Arterial spin-labeling in routine clinical practice, part 1: Technique and artifacts [J].
Deibler, A. R. ;
Pollock, J. M. ;
Kraft, R. A. ;
Tan, H. ;
Burdette, J. H. ;
Maldjian, J. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) :1228-1234
[4]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[5]   Cranial Dural Arteriovenous Fistula: Diagnosis and Classification with Time-Resolved MR Angiography at 3T [J].
Farb, R. I. ;
Agid, R. ;
Willinsky, R. A. ;
Johnstone, D. M. ;
terBrugge, K. G. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) :1546-1551
[6]   Comparison of Gadofosveset Trisodium and Gadobenate Dimeglumine During Time-Resolved Thoracic MR Angiography at 3T [J].
Frydrychowicz, Alex ;
Russe, Maximilian F. ;
Bock, Jelena ;
Stalder, Aurelien F. ;
Bley, Thorsten A. ;
Harloff, Andreas ;
Markl, Michael .
ACADEMIC RADIOLOGY, 2010, 17 (11) :1394-1400
[7]   Off-resonance effects in the transient response of SSFP sequences [J].
Ganter, C .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :368-375
[8]   Classification Schemes of Cranial Dural Arteriovenous Fistulas [J].
Gomez, Juan ;
Amin, Anubhav G. ;
Gregg, Lydia ;
Gailloud, Philippe .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2012, 23 (01) :55-+
[9]  
Helene Raoult EB, 2013, P 21 M INT SOC MAGN
[10]   Utility of time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material for assessment of intracranial dural arterio-venous fistula [J].
Hori, Masaaki ;
Aoki, Shigeki ;
Oishi, Hidenori ;
Nakanishi, Atsushi ;
Shimoji, Keigo ;
Kamagata, Koji ;
Houshito, Haruyoshi ;
Kuwatsuru, Ryohei ;
Arai, Hajime .
ACTA RADIOLOGICA, 2011, 52 (07) :808-812