In-Plane Shielding for CT: Effect of Off-Centering, Automatic Exposure Control and Shield-to-Surface Distance

被引:62
作者
Kalra, Mannudeep K. [1 ]
Dang, Pragya [1 ]
Singh, Sarabjeet [1 ]
Saini, Sanjay [1 ]
Shepard, Jo-Anne O. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
Tomography scanners; Computed tomography (CT); Radiation protection; Radiation dosage; DOSE ASSESSMENT; IMAGE QUALITY; DOSIMETRY; TISSUES; EYE;
D O I
10.3348/kjr.2009.10.2.156
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess effects of off-centering, automatic exposure control, and padding on attenuation values, noise, and radiation dose when using in-plane bismuth-based shields for CT scanning. Materials and Methods: A 30 cm anthropomorphic chest phantom was scanned on a 64-multidetector CT, with the center of the phantom aligned to the gantry isocenter. Scanning was repeated after placing a bismuth breast shield on the anterior surface with no gap and with 1, 2, and 6 cm of padding between the shield and the phantom surface. The "shielded" phantom was also scanned with combined modulation and off-centering of the phantom at 2 cm, 4 cm and 6 cm below the gantry isocenter. CT numbers, noise, and surface radiation dose were measured. The data were analyzed using an analysis of variance. Results: The in-plane shield was not associated with any significant increment for the surface dose or CT dose index volume, which was achieved by comparing the radiation dose measured by combined modulation technique to the fixed mAs (p > 0.05). Irrespective of the gap or the surface CT numbers, surface noise increased to a larger extent compared to Hounsfield unit (HU) (0-6 cm, 26-55%) and noise (0-6 cm, 30-40%) in the center. With off-centering, in-plane shielding devices are associated with less dose savings, although dose reduction was still higher than in the absence of shielding (0 cm off-center, 90% dose reduction; 2 cm, 61%) (p < 0.0001). Streak artifacts were noted at 0 cm and 1 cm gaps but not at 2 cm and 6 cm gaps of shielding to the surface distances. Conclusion: In-plane shields are associated with greater image noise, artifactually increased attenuation values, and streak artifacts. However, shields reduce radiation dose regardless of the extent of off-centering. Automatic exposure control did not increase radiation dose when using a shield.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 13 条
  • [1] Colombo Paola, 2004, Radiol Med, V108, P560
  • [2] Radiation dose reduction at a price: The effectiveness of a male gonadal shield during helical CT scans
    Dauer L.T.
    Casciotta K.A.
    Erdi Y.E.
    Rothenberg L.N.
    [J]. BMC Medical Imaging, 7 (1)
  • [3] In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data
    Fricke, BL
    Donnelly, LF
    Frush, DP
    Yoshizumi, T
    Varchena, V
    Poe, SA
    Lucaya, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 407 - 411
  • [4] Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    Geleijns, J.
    Salvado Artells, M.
    Veldkamp, W. J. H.
    Lopez Tortosa, M.
    Calzado Cantera, A.
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (10) : 2334 - 2340
  • [5] Orbital, thyroid, and breast superficial radiation shielding for patients undergoing diagnostic CT
    Hopper, KD
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2002, 23 (05) : 423 - 427
  • [6] Hopper KD, 2001, AM J NEURORADIOL, V22, P1194
  • [7] Strategies for CT radiation dose optimization
    Kalra, MK
    Maher, MM
    Toth, TL
    Hamberg, LM
    Blake, MA
    Shephard, JA
    Saini, S
    [J]. RADIOLOGY, 2004, 230 (03) : 619 - 628
  • [8] Automatic patient centering for MDCT: Effect on radiation dose
    Li, Jianhai
    Udayasankar, Unni K.
    Toth, Thomas L.
    Seamans, John
    Small, William C.
    Kalra, Mannudeep K.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 547 - 552
  • [9] Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users' needs?
    McLaughlin, DJ
    Mooney, RB
    [J]. CLINICAL RADIOLOGY, 2004, 59 (05) : 446 - 450
  • [10] MOSFET dosimetry for radiation dose assessment of bismuth shielding of the eye in children
    Mukundan, Srinivasan, Jr.
    Wang, Page Inman
    Frush, Donald P.
    Yoshizumi, Terry
    Marcus, Jeffrey
    Kloeblen, Emily
    Moore, Meredith
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (06) : 1648 - 1650