Design and development of a Building Facade Integrated Asymmetric Compound Parabolic Photovoltaic concentrator (BFI-ACP-PV)

被引:43
作者
Lu, Wei [1 ]
Wu, Yupeng [2 ]
Eames, Philip [3 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Nottingham, Dept Architecture & Built Environm, Fac Engn, Nottingham NG7 2RD, England
[3] Loughborough Univ Technol, Ctr Renewable Energy Syst Technol, Loughborough LE11 3TU, Leics, England
关键词
Building Facade Integrated Asymmetric; Compound Parabolic PV concentrator; Phase Change Materials; Power output; Solar to electrical conversion efficiency; Electrical power losses; PHASE-CHANGE MATERIAL; SOLAR THERMAL APPLICATIONS; TEMPERATURE RISE; COOLING DUCTS; PERFORMANCE; SYSTEM; COLLECTORS; ENHANCEMENT; IMPROVE; BICPV;
D O I
10.1016/j.apenergy.2018.03.071
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building Integrated PV and Concentrating PV can generate electricity onsite and provide savings in materials and electricity costs, as well as protecting buildings from weather. In this paper, a novel truncated stationary asymmetric compound parabolic photovoltaic concentrator with a geometric concentration ratio of 2.0 has been designed and experimental characterised. The designed system is suitable for building facade application, especially for vertical facade. It has wide acceptance half angles of 0 degrees and 55 degrees, this acceptance angle range enables the concentrator to operate year-round at its geometric gain in most of the UK and EU climatic condition. A comprehensive indoor test was carried out to evaluate the electrical and thermal characterisation of the developed Building Facade Integrated Asymmetric Compound Parabolic Photovoltaic concentrator (BFI-ACP-PV) system, and also the factors that affect the power output of the developed system. The experimental results showed that the developed BFI-ACP-PV system has the potential to increase the power output per unit solar cell area by a factor of 2, when compared with a non-concentrating PV system. Subsequently, a Phase Change Material (PCM) system was integrated to the rear of the BFI-ACP-PV system to moderate the PV temperature rise and maintain good solar to electrical conversion efficiency. It was found out that the electrical conversion efficiency for the BFI-ACP-PV coupled PCM system was increased by over 5% compared with a similar system with no PCM integrated at the rear, when the incident solar radiation intensity was 280 W/m(2), this value increased by over 10% for an incident solar radiation intensity of 670 W/m(2).
引用
收藏
页码:325 / 336
页数:12
相关论文
共 36 条
  • [1] [Anonymous], 2009, THESIS
  • [2] Phase-change materials to improve solar panel's performance
    Biwole, Pascal Henry
    Eclache, Pierre
    Kuznil, Frederic
    [J]. ENERGY AND BUILDINGS, 2013, 62 : 59 - 67
  • [3] Optimum depth for PV cooling ducts
    Brinkworth, B. J.
    [J]. SOLAR ENERGY, 2006, 80 (09) : 1131 - 1134
  • [4] Design procedure for cooling ducts to minimise efficiency loss due to temperature rise in PV arrays
    Brinkworth, BJ
    Sandberg, M
    [J]. SOLAR ENERGY, 2006, 80 (01) : 89 - 103
  • [5] Thermal regulation of photovoltaic cladding
    Brinkworth, BJ
    Cross, BM
    Marshall, RH
    Yang, HX
    [J]. SOLAR ENERGY, 1997, 61 (03) : 169 - 178
  • [6] Heat retention of a photovoltaic/thermal collector with PCM
    Browne, Maria C.
    Norton, Brian
    McCormack, Sarah J.
    [J]. SOLAR ENERGY, 2016, 133 : 533 - 548
  • [7] Performance study of heat-pipe solar photovoltaic/thermal heat pump system
    Chen, Hongbing
    Zhang, Lei
    Jie, Pengfei
    Xiong, Yaxuan
    Xu, Peng
    Zhai, Huixing
    [J]. APPLIED ENERGY, 2017, 190 : 960 - 980
  • [8] Transmittance and Reflectance Studies of Thermotropic Material for a Novel Building Integrated Concentrating Photovoltaic (BICPV) 'Smart Window' System
    Connelly, Karen
    Wu, Yupeng
    Ma, Xiaoyu
    Lei, Yu
    [J]. ENERGIES, 2017, 10 (11):
  • [9] Design and development of a reflective membrane for a novel Building Integrated Concentrating Photovoltaic (BICPV) 'Smart Window' system
    Connelly, Karen
    Wu, Yupeng
    Chen, Jun
    Lei, Yu
    [J]. APPLIED ENERGY, 2016, 182 : 331 - 339
  • [10] Deutsche Gesellschaft Fur Sonnenenergie, 2005, PLANN INST PHOT SYST