Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening

被引:62
作者
Han, Daiwei [1 ]
Heuvelmans, Marjolein A. [1 ]
Oudkerk, Matthijs [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, Groningen, Netherlands
关键词
Semi-automated volume measurement; manual diameter measurement; small pulmonary nodule; LOW-DOSE CT; BASE-LINE; ITERATIVE RECONSTRUCTION; TUMOR MEASUREMENTS; CHEST CT; VARIABILITY; SEGMENTATION; PROBABILITY; SCANS; SIZE;
D O I
10.21037/tlcr.2017.01.05
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Currently, lung cancer screening by low-dose chest CT is implemented in the United States for high-risk persons. A disadvantage of lung cancer screening is the large number of small-to-intermediate sized lung nodules, detected in around 50% of all participants, the large majority being benign. Accurate estimation of nodule size and growth is essential in the classification of lung nodules. Currently, manual diameter measurements are the standard for lung cancer screening programs and routine clinical care. However, European screening studies using semi-automated volume measurements have shown higher accuracy and reproducibility compared to diameter measurements. In addition to this, with the optimization of CT scan techniques and reconstruction parameters, as well as advances in segmentation software, the accuracy of nodule volume measurement can be improved even further. The positive results of previous studies on volume and diameter measurements of lung nodules suggest that manual measurements of nodule diameter may be replaced by semi-automated volume measurements in the (near) future.
引用
收藏
页码:52 / 61
页数:10
相关论文
共 47 条
  • [1] Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
    Aberle, Denise R.
    Adams, Amanda M.
    Berg, Christine D.
    Black, William C.
    Clapp, Jonathan D.
    Fagerstrom, Richard M.
    Gareen, Ilana F.
    Gatsonis, Constantine
    Marcus, Pamela M.
    Sicks, JoRean D.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) : 395 - 409
  • [2] [Anonymous], 1975, PREVIOUS VERSION SEE
  • [3] [Anonymous], CHEST, DOI DOI 10.1378/CHEST.07-1352
  • [4] Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time
    Aoki, T
    Nakata, H
    Watanabe, H
    Nakamura, K
    Kasai, T
    Hashimoto, H
    Yasumoto, K
    Kido, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) : 763 - 768
  • [5] Optimal Dose Levels in Screening Chest CT for Unimpaired Detection and Volumetry of Lung Nodules, with and without Computer Assisted Detection at Minimal Patient Radiation
    Christe, Andreas
    Szucs-Farkas, Zsolt
    Huber, Adrian
    Steiger, Philipp
    Leidolt, Lars
    Roos, Justus E.
    Heverhagen, Johannes
    Ebner, Lukas
    [J]. PLOS ONE, 2013, 8 (12):
  • [6] Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
    Das, Marco
    Ley-Zaporozhan, Julia
    Gietema, H. A.
    Czech, Andre
    Muehlenbruch, Georg
    Mahnken, Andreas H.
    Katoh, Markus
    Bakai, Annemarie
    Salganicoff, Marcos
    Diederich, Stefan
    Prokop, Mathias
    Kauczor, Hans-Ulrich
    Guenther, Rolf W.
    Wildberger, Joachim E.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (08) : 1979 - 1984
  • [7] Dingemans A-MC, 2015, LUNG CANCER, P293
  • [8] Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-influence of inspiration level, nodule size, and segmentation performance
    Gietema, Hester A.
    Schaefer-Prokop, Cornelia M.
    Mali, Willem P. T. M.
    Groenewegen, Gerard
    Prokop, Mathias
    [J]. RADIOLOGY, 2007, 245 (03) : 888 - 894
  • [9] Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements
    Gietema, Hester A.
    Wang, Ying
    Xu, Dongming
    van Klaveren, Rob J.
    deKoning, Harry
    Scholten, Ernst
    Verschakelen, Johny
    Kohl, Gerhard
    Oudkerk, Matthijs
    Prokop, Mathias
    [J]. RADIOLOGY, 2006, 241 (01) : 251 - 257
  • [10] Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    Goodman, LR
    Gulsun, M
    Washington, L
    Nagy, PG
    Piacsek, KL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (04) : 989 - 994