Three-dimensional measurement of elemental distribution in minute samples by combination of in-air micro-PIXE and STIM

被引:10
作者
Satoh, T. [1 ]
Oikawa, M. [1 ]
Kamiya, T. [1 ]
机构
[1] Japan Atom Energy Agcy, Takasaki Adv Radiat Res Inst, Takasaki, Gunma 3701292, Japan
关键词
Micro-PIXE; STIM; SYSTEM;
D O I
10.1016/j.nimb.2009.03.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A technique of measuring three-dimensional (3D) distribution of trace elements in a minute sample was studied using the in-air micro-PIXE (Particle Induced X-ray Emission) system. A 3D distribution was acquired by means of reconstructing numbers of projection images of the sample obtained by micro-PIXE analyses from different directions. This is basically the same technique as X-ray CT (Computed Tomography). However, when this technique was applied to the in-air micro-PIXE analysis, the X-ray yields should be corrected in taking account of such parameters as the X-ray production cross section, the Xray attenuation coefficient, the energy of an incident particle, and the 3D densities of major elements in the analysis sample. In this study, STIM (Scanning Transmission Ion Microscopy)-CT was used to obtain the 3D density map of the sample. Corrected 3D distributions of sulfur and iron in a minute test sample were successfully measured with this technique in combination of STIM-CT and in-air micro-PIXE. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2125 / 2127
页数:3
相关论文
共 14 条
[1]   Elemental analysis of cellular samples by in-air micro-PIXE [J].
Ishii, K ;
Sugimoto, A ;
Tanaka, A ;
Satoh, T ;
Matsuyama, S ;
Yamazaki, H ;
Akama, C ;
Amartivan, T ;
Endoh, H ;
Oishi, Y ;
Yuki, H ;
Sugihara, S ;
Satoh, M ;
Kamiya, T ;
Sakai, T ;
Arakawa, K ;
Saidoh, M ;
Oikawa, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 :448-453
[2]   STIM tomography at the cell level [J].
Michelet, C ;
Moretto, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 158 (1-4) :361-367
[3]  
MORITA S, 1988, J ACCELERATOR SCI TE, V2, P57
[4]   Subcellular changes of essential metal shown by in-air micro-PIXE in oral cadmium-exposed mice [J].
Nakazato, Kyoumi ;
Nagamine, Takeaki ;
Suzuki, Keij ;
Kusakabe, Takahiko ;
Moon, H. D. ;
Oikawa, Masakazu ;
Sakai, Takuro ;
Arakawa, Kazuo .
BIOMETALS, 2008, 21 (01) :83-91
[5]   Micro-pixe study on sorption behaviors of cobalt by lichen biomass [J].
Ohnuki, T ;
Sakamoto, F ;
Kozai, N ;
Sakai, T ;
Kamiya, T ;
Satoh, T ;
Oikawa, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 :407-411
[6]   New in-air micro-PIXE system for biological applications [J].
Sakai, T ;
Oikawa, M ;
Sato, T ;
Nagamine, T ;
Moon, HD ;
Nakazato, K ;
Suzuki, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 231 :112-116
[7]   JAERI Takasaki in-air micro-PIXE system for various applications [J].
Sakai, T ;
Kamiya, T ;
Oikawa, M ;
Sato, T ;
Tanaka, A ;
Ishii, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 190 :271-275
[8]  
Sakai T., 2000, INT J PIXE, V10, P91
[9]   Three-dimensional ion micro-tomography [J].
Sakellariou, A ;
Jamieson, DN ;
Legge, GJF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 :211-218
[10]   Direct visualization and quantification of the anticancer agent, cis-diamminedichloro-platinum(II), in human lung cancer cells using in-air microparticle-induced X-ray emission analysis [J].
Sakurai, Hideyuki ;
Okamoto, Masahiko ;
Hasegawa, Masatoshi ;
Satoh, Takahiro ;
Oikawa, Masakazu ;
Kamiya, Tomihiro ;
Arakawa, Kazuo ;
Nakano, Takashi .
CANCER SCIENCE, 2008, 99 (05) :901-904