Three-dimensional measurement of elemental distribution in minute samples by combination of in-air micro-PIXE and STIM

被引:10
|
作者
Satoh, T. [1 ]
Oikawa, M. [1 ]
Kamiya, T. [1 ]
机构
[1] Japan Atom Energy Agcy, Takasaki Adv Radiat Res Inst, Takasaki, Gunma 3701292, Japan
关键词
Micro-PIXE; STIM; SYSTEM;
D O I
10.1016/j.nimb.2009.03.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A technique of measuring three-dimensional (3D) distribution of trace elements in a minute sample was studied using the in-air micro-PIXE (Particle Induced X-ray Emission) system. A 3D distribution was acquired by means of reconstructing numbers of projection images of the sample obtained by micro-PIXE analyses from different directions. This is basically the same technique as X-ray CT (Computed Tomography). However, when this technique was applied to the in-air micro-PIXE analysis, the X-ray yields should be corrected in taking account of such parameters as the X-ray production cross section, the Xray attenuation coefficient, the energy of an incident particle, and the 3D densities of major elements in the analysis sample. In this study, STIM (Scanning Transmission Ion Microscopy)-CT was used to obtain the 3D density map of the sample. Corrected 3D distributions of sulfur and iron in a minute test sample were successfully measured with this technique in combination of STIM-CT and in-air micro-PIXE. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2125 / 2127
页数:3
相关论文
共 11 条
  • [1] Elemental analysis of cellular samples by in-air micro-PIXE
    Ishii, K
    Sugimoto, A
    Tanaka, A
    Satoh, T
    Matsuyama, S
    Yamazaki, H
    Akama, C
    Amartivan, T
    Endoh, H
    Oishi, Y
    Yuki, H
    Sugihara, S
    Satoh, M
    Kamiya, T
    Sakai, T
    Arakawa, K
    Saidoh, M
    Oikawa, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 448 - 453
  • [2] Preliminary study on the elemental quantification of in ambient liquid samples of microliter volume using the in-air micro-PIXE technique
    Ma C.-J.
    Lim C.-S.
    Sakai T.
    Asian Journal of Atmospheric Environment, 2017, 11 (1) : 54 - 60
  • [3] Elemental analysis of rat basophilic leuckemia cells (2H3) by in-air micro-PIXE
    Sakurai, E
    Mizuma, K
    Sakai, T
    Satoh, T
    Kamiya, T
    Yamazaki, H
    Ishii, K
    Yanai, K
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2004, 94 : 128P - 128P
  • [4] Analysis of tissue cadmium distribution in chronic cadmium-exposed mice using in-air micro-PIXE
    T. Nagamine
    K. Nakazato
    K. Suzuki
    T. Kusakabe
    T. Sakai
    M. Oikawa
    T. Satoh
    T. Kamiya
    K. Arakawa
    Biological Trace Element Research, 2007, 117 : 115 - 126
  • [5] Analysis of tissue cadmium distribution in chronic cadmium-exposed mice using in-air micro-PIXE
    Nagamine, T.
    Nakazato, K.
    Suzuki, K.
    Kusakabe, T.
    Sakai, T.
    Oikawa, A.
    Satoh, T.
    Kamiya, T.
    Arakawa, K.
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2007, 117 (1-3) : 115 - 126
  • [6] Element-selective three-dimensional imaging of microparticles with a confocal micro-PIXE arrangement
    Zitnik, M.
    Pelicon, P.
    Bucar, K.
    Grlj, N.
    Karydas, A. G.
    Sokaras, D.
    Schuetz, R.
    Kanngiesser, B.
    X-RAY SPECTROMETRY, 2009, 38 (06) : 526 - 539
  • [7] Evaluation of caries progression in dentin treated by fluoride-containing materials using an in-air micro-PIGE and micro-PIXE measurement system
    Yamamoto, H.
    Iwami, Y.
    Yagi, K.
    Hayashi, M.
    Komatsu, H.
    Okuyama, K.
    Matsuda, Y.
    Yasuda, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 348 : 152 - 155
  • [8] An application of micro X-ray fluorescence computed tomography for the determination of three-dimensional elemental distribution in a single hair strand
    Kondo, Ryosuke
    Yamato, Takuma
    Munoz-Noval, Alvaro
    Honda, Sadao
    Nishiwaki, Yoshinori
    Komaguchi, Kenji
    Hayakawa, Shinjiro
    Journal of Analytical Atomic Spectrometry, 2021, 36 (05): : 1041 - 1046
  • [9] An application of micro X-ray fluorescence computed tomography for the determination of three-dimensional elemental distribution in a single hair strand
    Kondo, Ryosuke
    Yamato, Takuma
    Munoz-Noval, Alvaro
    Honda, Sadao
    Nishiwaki, Yoshinori
    Komaguchi, Kenji
    Hayakawa, Shinjiro
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (05) : 1041 - 1046
  • [10] MEASUREMENT OF THREE-DIMENSIONAL TIME-AVERAGED VOID FRACTION DISTRIBUTION IN ROD BUNDLE IN AIR-WATER SYSTEM BY X-RAY CT TECHNIQUE
    Katono, Kenichi
    Nukaga, Jun
    Nagayoshi, Takuji
    Yasuda, Kenichi
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,