Corneal infections after implantation of intracorneal ring segments

被引:52
|
作者
Hofling-Lima, AL
Branco, BC
Romano, AC
Campos, MQS
Moreira, H
Miranda, D
Kwitko, S
de Freitas, D
Casanova, F
Sartori, M
Schor, P
Souza, LB
机构
[1] Univ Fed Sao Paulo, Paulista Sch Med, Dept Ophthalmol, BR-04524020 Sao Paulo, Brazil
[2] Univ Fed Parana, Dept Ophthalmol, BR-80060000 Curitiba, Parana, Brazil
[3] Univ Fed Rio Grande Sul, Dept Ophthalmol, Rio Grande do Sul, Brazil
关键词
keratoconus; keratitis; bacterial infections; fungal eye infections; prostheses; implants;
D O I
10.1097/01.ico.0000126434.95325.24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report risk factors, clinical course, and outcome in patients with infectious keratitis following implantation of intracorneal ring segments (ICRS). Methods: The records of 8 patients with culture-proven infectious keratitis after ICRS (Ferrara(R) or Intacs(R)) implantation were retrospectively reviewed. Age, gender, corneal findings, ocular abnormalities, the condition that led to ICRS implantation, immediate prior use of a contact lens, elapsed time between implantation and the onset of symptoms, previous medications, and systemic disorders were noted. Results: Culture-positive infectious keratitis developed in 7 eyes of 7 patients (2 men and 5 women) with a mean age of 35 years who underwent Ferrara implantantion for the treatment of keratoconus and in a 29-year-old man who underwent Intacs implantation for correction of low myopia. Contact lens use, diabetes, and trauma were factors possibly associated with the risk of infection in three cases. Microorganisms, identified in all cases, included Staphylococcus aureus, Streptococcus viridans, Streptococcus pneumoniae, Pseudomonas sp, Nocardia sp, Klebsiella sp, and Paecylomices sp. Onset of symptoms of infection varied from less than 1 week to 22 months postoperatively, depending on the infecting organism. Conclusions: infectious keratitis following ICRS implantation is a sight-threatening complication for which early recognition and rapid institution of appropriate treatment may result in a better visual outcome.
引用
收藏
页码:547 / 549
页数:3
相关论文
共 50 条
  • [1] Intracorneal Ring Segments Implantation for Corneal Ectasia
    Giacomin, Natalia T.
    Mello, Glauco R.
    Medeiros, Carla S.
    Kilic, Alyin
    Serpe, Cristine C.
    Almeida, Hirlana G.
    Kara-Junior, Newton
    Santhiago, Marcony R.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (12) : 829 - +
  • [2] Corneal infections after implantation of intracorneal ring segments (vol 23, pg 547, 2004)
    Casanova, FH
    CORNEA, 2004, 23 (07) : CP4 - CP4
  • [3] Reliability of corneal tomography after implantation of intracorneal ring segments for keratoconus
    Matar, C.
    Daas, L.
    Suffo, S.
    Langenbucher, A.
    Seitz, B.
    Eppig, T.
    OPHTHALMOLOGE, 2020, 117 (11): : 1092 - 1099
  • [4] Visian toric ICL implantation after intracorneal ring segments implantation and corneal collagen crosslinking in keratoconus
    Dirani, Ali
    Fadlallah, Ali
    Khoueir, Ziad
    Antoun, Joelle
    Cherfan, George
    Jarade, Elias
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (03) : 338 - 344
  • [5] Diurnal stability of refraction after implantation with intracorneal ring segments
    Twa, MD
    Hurst, TJ
    Walker, JG
    Waring, GO
    Schanzlin, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04): : 516 - 523
  • [6] Implantation of Intracorneal Ring Segments in Keratectasia: Effects on Corneal Biomechanics in 112 Eyes
    Hamon, Loic
    Pfahl, Luisa J.
    Flockerzi, Elias
    Berger, Tim
    Langenbucher, Achim
    Seitz, Berthold
    Daas, Loay
    CORNEA, 2024, 43 (06) : 702 - 709
  • [7] Contact lenses fitting after intracorneal ring segments implantation in keratoconus
    Moreira, Luciane Bugmann
    Canto Bardal, Ricardo Augustho
    Crisigiovanni, Leila Roberta
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2013, 76 (04) : 215 - 217
  • [9] Corneal Biomechanical Changes After Intracorneal Ring Segment Implantation in Keratoconus
    Pinero, David P.
    Alio, Jorge L.
    Barraquer, Rafael I.
    Michael, Ralph
    CORNEA, 2012, 31 (05) : 491 - 499
  • [10] Intracorneal ring segments in ectatic corneal disease - a review
    Pinero, David P.
    Alio, Jorge L.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (02): : 154 - 167