Amperometric Immunosensor for Detection of Celiac Disease Toxic Gliadin Based on Fab Fragments

被引:58
作者
Nassef, Hossam M. [1 ]
Civit, Laia [1 ]
Fragoso, Alex [1 ]
O'Sullivan, Ciara K. [1 ,2 ]
机构
[1] Univ Rovira & Virgili, Dept Chem Engn, Nanobiotechnol & Bioanal Grp, Tarragona 43007, Spain
[2] ICREA, Barcelona 08010, Spain
关键词
SITE-DIRECTED IMMOBILIZATION; ANTIBODY FRAGMENTS; ORIENTED IMMOBILIZATION; BIOSENSOR; PROTEIN; GOLD; SENSITIVITY; PREVALENCE; MONOLAYERS; SURFACES;
D O I
10.1021/ac9005342
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Immunosensor sensitivity is strongly dependent on the density of free active epitopes per surface area, which could be achieved via well-oriented immobilization of antibody fragments as bioreceptor molecules. Here, we report on the development of an electrochemical gliadin immunosensor based on the spontaneous self-assembly of antigliadin Fab fragments (CDC5-Fab) on Au surfaces. The analytical performance of this immunosensor is compared with a similar containing whole CDC5 antibodies previously modified with thiol groups (CDC5-SH) as the recognition element. Fab fragments were generated by reduction of the disulfide bond of F(ab)(2) fragments obtained by bromelain digestion of CDC5 antibody. Surface plasmon resonance (SPR) was used to evaluate the degree of immobilization and recognition ability of immobilized CDC5-Fab and CDC5-SH on gold surfaces. The studied surface chemistries were evaluated in terms of time required for SAM formation, stability, susceptibility to nonspecific interactions, and sensitivity using surface plasmon resonance, electrochemical impedance spectroscopy (EIS), and amperometry. CDC5-Fab formed a stable monolayer on gold after 15 min and retained > 90% of antigen recognition ability after 2 months of storage at 4 degrees C. Detection of gliadin of Fab modified electrodes was evaluated by impedance and amperometry. Labeless impedimetric detection achieved a LOD of 0.42 mu g/mL while the amperometric immunosensor based on Fab fragments showed a highly sensitive response with an LOD of 3.29 ng/mL. The Fab based immunosensor offers the advantages of being highly sensitive, easy, and rapid to prepare, with a low assay time.
引用
收藏
页码:5299 / 5307
页数:9
相关论文
共 39 条
[1]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[2]   MOLECULAR FRAGMENTATION - SOME APPLICATIONS IN IMMUNOLOGY [J].
BEALE, D .
DEVELOPMENTAL AND COMPARATIVE IMMUNOLOGY, 1987, 11 (02) :287-296
[3]  
Bia M., 1995, CHIN MED SCI J, V10, P78
[4]   Comparison of random and oriented immobilisation of antibody fragments on mixed self-assembled monolayers [J].
Bonroy, Kristien ;
Frederix, Filip ;
Reekmans, Gunter ;
Dewolf, Ellen ;
De Palma, Randy ;
Borghs, Gustaaf ;
Declerck, Paul ;
Goddeeris, Bruno .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 312 (1-2) :167-181
[5]   Direct oriented immobilization of F(ab′) antibody fragments on gold [J].
Brogan, KL ;
Wolfe, KN ;
Jones, PA ;
Schoenfisch, MH .
ANALYTICA CHIMICA ACTA, 2003, 496 (1-2) :73-80
[6]  
Cass T., 1998, IMMOBILIZED BIOMOLEC
[7]  
CICLITIRA PJ, 2008, P 12 INT CEL S NEW Y
[8]   SIMPLIFIED PREPARATION OF RABBIT FAB FRAGMENTS [J].
COULTER, A ;
HARRIS, R .
JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 59 (02) :199-203
[9]   Comparison of antibody functionality using different immobilization methods [J].
Danczyk, R ;
Krieder, B ;
North, A ;
Webster, T ;
HogenEsch, H ;
Rundell, A .
BIOTECHNOLOGY AND BIOENGINEERING, 2003, 84 (02) :215-223
[10]   The prevalence of celiac disease in average-risk and at-risk Western European populations:: A systematic review [J].
Dubé, C ;
Rostom, A ;
Sy, R ;
Cranney, A ;
Saloojee, N ;
Garritty, C ;
Sampson, M ;
Zhang, L ;
Yazdi, F ;
Mamaladze, V ;
Pan, I ;
Macneil, J ;
Mack, D ;
Patel, D ;
Moher, D .
GASTROENTEROLOGY, 2005, 128 (04) :S57-S67