Cemented all polyethylene tibial insert unicompartimental knee arthroplasty: A long term follow-up study

被引:51
|
作者
Lustig, S. [1 ]
Paillot, J. -L. [1 ]
Servien, E. [1 ]
Henry, J. [1 ]
Selmi, T. Ait Si [1 ]
Neyret, P. [1 ]
机构
[1] N Hosp Grp, Albert Trillat Ctr, Ctr Livet, Knee Surg Dept, F-69300 Caluire Et Cuire, France
关键词
Unicompartmental replacement; Knee; UNICOMPARTMENTAL ARTHROPLASTY; REPLACEMENT; SURVIVORSHIP; PROSTHESIS; MINIMUM; ARTHROSIS; REVISION; WEAR;
D O I
10.1016/j.otsr.2008.04.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Unicompartimental knee arthroplasty outcome is sometimes compared to total knee arthroplasty but various implant parameters might greatly influence this outcome. The objectives of this study were to report the results of a consecutive series of 172 all-polyethylene unicompartmental knee arthroplasties (UKAs) and to detail possible factors of success and failure. Hypothesis.-It is possible to outline implant and technique factors determining success or failure in unicompartimental knee arthroplasty. Materials and methods.-One hundred seventy-two HLS-type cemented resurfacing UKAs, with the femoral implant made of chrome-cobalt and the tibial implant tibial entirely in polyethylene (without anchorage studs) were consecutively implanted between 1988 and 2004 in 134 patients (111 females and 23 males) in our center according to the indications established in 1988, using the same technique for each surgery. The patients' mean age was 72.2 years (range, 25-90 years). The review rate was 83.7% (144 UKAs), with a mean follow-up of 62.3 months (range, 24-160 months). The series included 84 medial UKAs and 60 lateral UKAs. The clinical data were analyzed using the IKS criteria and the patients had a complete radiological evaluation before surgery and at the last follow-up. Results.-The rate of satisfied or very satisfied patients was 97.2%. No pain or slight pain was found in 81% of the cases. The mean flexion was 133 degrees (range, 85-150 degrees). The mean knee score varied from 63.6 before surgery to 91.5 (90.4 for medial UKAs and 92.9 for lateral UKAs) and the function score from 63.6 to 83.8 (84.7 for medial UKAs and 82.6 for lateral UKAs). The mean range of motion was 133 degrees (range, 85-150 degrees), better than the medial UKAs for osteonecrosis. A radiolucency was found in 23% of the cases (20% tibial and 3% femoral), nonprogressive in all cases. In 87.2% of the cases, the opposite femorotibial compartment remained radiologically normal. No progression to osteoarthritis in the femoropatellar joint required additional surgery. Sixteen patients required revision surgery: in six cases, the implant was removed and a total prosthesis implanted ( one late infection, one case of involvement of the opposite compartment, and four cases of tibial component loosening). In the other cases, one tibial baseplate was changed, five arthroscopies were done, and four unicompartmental knee replacements were done on the opposite compartment. The Kaplan-Meier survival rate ( taking into account the revisions with implant change) was 95.6. The results of this series were very satisfactory and were similar to recent series in the world literature that showed survival rates between 90 and 98% at 10 years, rates that are equivalent to those found for total knee replacements. The mean flexion range of motion found was higher than the majority of other recent series, probably because of the precise patient selection in the present study, a minimally invasive approach, and the femoral implant design with an ascending condylar posterior cut. The deterioration of the contralateral compartment is frequently reported, but was perhaps prevented by the absence of overcorrection and patient selection. In this series, none of the UKAs was revised for wear. We explain this by the systematic preservation of a moderate undercorrection, particularly for medial UKAs, the quality of the polyethylene, and a selection based on patient weight and age. Conclusions.-The option of an all-polyethylene tibial implant, with minimal bone cuts (femoral resurfacing), makes excellent long-term results possible.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [31] Long-Term Follow-Up of Medial Pivot Total Knee Arthroplasty: A Systematic Review of the Current Evidence
    Cacciola, Giorgio
    Giustra, Fortunato
    Bosco, Francesco
    Sabatini, Luigi
    Risitano, Salvatore
    De Meo, Federico
    Braconi, Lorenzo
    Cavaliere, Pietro
    Masse, Alessandro
    Solarino, Giuseppe
    PROSTHESIS, 2023, 5 (03): : 622 - 634
  • [32] Long-term results of a total knee prosthesis utilising an all polyethylene tibial component
    Sunil K. Pai
    George Whitwell
    David McMurray
    Todd D. Stewart
    Martin H. Stone
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1143 - 1148
  • [33] Long-term results (after a mean 11.3 years, and up to 22 years, of follow-up) of the Legacy Constrained Condylar Knee (LCCKTM) in primary total knee arthroplasty
    Urbain, Antoine
    Putman, Sophie
    Migaud, Henri
    Pasquier, Gilles
    Girard, Julien
    Dartus, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (03)
  • [34] Isolated Tibial Polyethylene Insert Exchange After Total Knee Arthroplasty for Treatment of Instability and/or Polyethylene Wear
    Alexander, Jacob S.
    Richardson, Eleanor
    Crawford, David A.
    Berend, Keith R.
    Morris, Michael J.
    Lombardi, Adolph V., Jr.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2023, 42
  • [35] Long-term follow-up of total hip arthroplasty using polyethylene-ceramic composite (sandwich) liner
    Rodriguez-Perez, Daniel
    Carnaval, Thiago
    Rodriguez, Marcos-del-Carmen
    Coscujuela-Mana, Antonio
    Agullo, Jose-Luis
    Videla, Sebastian
    HIP INTERNATIONAL, 2024, 34 (04) : 467 - 475
  • [36] Long-term survival of the cemented Muller CDH stem: a minimum follow-up of 10 years
    Salentiny, Yves
    Zwicky, Lukas
    Ochsner, Peter E.
    Clauss, Martin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (10) : 1471 - 1477
  • [37] Revision Total Hip Arthroplasty for Ceramic Head Fracture A Long-Term Follow-Up
    Sharma, Vineet
    Ranawat, Amar S.
    Rasquinha, Vijay J.
    Weiskopf, JoAnne
    Howard, Holly
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03) : 342 - 347
  • [38] A randomised trial of all-polyethylene and metal-backed tibial components in unicompartmental arthroplasty of the knee
    Hutt, J. R. B.
    Farhadnia, P.
    Masse, V.
    Lavigne, M.
    Vendittoli, P-A.
    BONE & JOINT JOURNAL, 2015, 97B (06) : 786 - 792
  • [39] A Mid-term Follow-up Study on the Reimplantation of Autoclaved Femoral and Tibial Components as Spacers for Treating Infected Total Knee Arthroplasty
    Li, Peng
    Zhu, Zhiqi
    Tang, Xiangyang
    Shi, Zhanjun
    ORTHOPAEDIC SURGERY, 2022, 14 (09) : 2042 - 2049
  • [40] Long-term functional success and robust implant survival in lateral unicompartmental knee arthroplasty: A case series with a mean follow-up of twenty two and a half years
    Favroul, Clement
    Batailler, Cecile
    Thouvenin, Clara
    Shatrov, Jobe
    Neyret, Philippe
    Servien, Elvire
    Lustig, Sebastien
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (07) : 1761 - 1769