Bioaerosol emissions and detection of airborne antibiotic resistance genes from a wastewater treatment plant

被引:131
|
作者
Li, Jing [1 ]
Zhou, Liantong [2 ]
Zhang, Xiangyu [1 ]
Xu, Caijia [1 ]
Dong, Liming [2 ]
Yao, Maosheng [1 ]
机构
[1] Peking Univ, State Key Joint Lab Environm Simulat & Pollut Con, Coll Environm Sci & Engn, Beijing 100871, Peoples R China
[2] Beijing Technol & Business Univ, Dept Environm Sci & Engn, Beijing 100048, Peoples R China
基金
对外科技合作项目(国际科技项目);
关键词
Wastewater treatment plant; Bioaerosols; Airborne antibiotic resistance genes; Bacterial aerosols; Fungal aerosols; Bacterial pathogens; WORK-RELATED SYMPTOMS; SULFONAMIDE RESISTANCE; TREATMENT SYSTEMS; ESCHERICHIA-COLI; ACTIVATED-SLUDGE; SEWAGE; TETRACYCLINE; BACTERIA; MICROORGANISMS; INTEGRONS;
D O I
10.1016/j.atmosenv.2015.06.030
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air samples from twelve sampling sites (including seven intra-plant sites, one upwind site and four downwind sites) from a wastewater treatment plant (WWTP) in Beijing were collected using a Reuter Centrifugal Sampler High Flow (RCS); and their microbial fractions were studied using culturing and high throughput gene sequence. In addition, the viable (fluorescent) bioaerosol concentrations for 7 intra-plant sites were also monitored for 30 min each using an ultraviolet aerodynamic particle sizer (UV-APS). Both air and water samples collected from the plant were investigated for possible bacterial antibiotic resistance genes and integrons using polymerase chain reaction (PCR) coupled with gel electrophoresis. The results showed that the air near sludge thickening basin was detected to have the highest level of culturable bacterial aerosols (up to 1697 CFU/m(3)) and fungal aerosols (up to 930 CFU/m(3)). For most sampling sites, fluorescent peaks were observed at around 3-4 mu m, except the office building with a peak at 1.5 mu m, with a number concentration level up to 1233-6533 Particles/m(3). About 300 unique bacterial species, including human opportunistic pathogens, such as Comamonas Testosteroni and Moraxella Osloensis, were detected from the air samples collected over the biological reaction basin. In addition, we have detected the sul2 gene resistant to cotrimoxazole (also known as septra, bactrim and TMP-SMX) and class 1 integrase gene from the air samples collected from the screen room and the biological reaction basin. Overall, the screen room, sludge thickening basin and biological reaction basin imposed significant microbial exposure risks, including those from airborne antibiotic resistance genes. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:404 / 412
页数:9
相关论文
共 50 条
  • [21] Impacts of advanced treatment processes on elimination of antibiotic resistance genes in a municipal wastewater treatment plant
    Yang, Lian
    Wen, Qinxue
    Chen, Zhiqiang
    Duan, Ran
    Yang, Pan
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2019, 13 (03)
  • [22] Impacts of advanced treatment processes on elimination of antibiotic resistance genes in a municipal wastewater treatment plant
    Lian Yang
    Qinxue Wen
    Zhiqiang Chen
    Ran Duan
    Pan Yang
    Frontiers of Environmental Science & Engineering, 2019, 13
  • [23] Characterization of airborne antibiotic resistance genes from typical bioaerosol emission sources in the urban environment using metagenomic approach
    Yang, Ying
    Zhou, Renjun
    Chen, Baowei
    Zhang, Tong
    Hu, Ligang
    Zou, Shichun
    CHEMOSPHERE, 2018, 213 : 463 - 471
  • [24] Occurrence and removal of antibiotic resistant Escherichia coli and antibiotic resistance genes in an urban wastewater treatment plant
    Le T.H.
    Tong D.K.
    Pham T.T.V.
    Hoang T.L.
    Tran T.K.
    Ng C.
    International Journal of Environmental Science and Technology, 2023, 20 (12) : 13739 - 13752
  • [25] Distribution, sources, and potential risks of antibiotic resistance genes in wastewater treatment plant: A review
    Wang, Ying
    Han, Yunping
    Li, Lin
    Liu, Junxin
    Yan, Xu
    ENVIRONMENTAL POLLUTION, 2022, 310
  • [26] Seasonality of antibiotic prescriptions for outpatients and resistance genes in sewers and wastewater treatment plant outflow
    Caucci, Serena
    Karkman, Antti
    Cacace, Damiano
    Rybicki, Marcus
    Timpel, Patrick
    Voolaid, Veiko
    Gurke, Robert
    Virta, Marko
    Berendonk, Thomas U.
    FEMS MICROBIOLOGY ECOLOGY, 2016, 92 (05)
  • [27] Occurrence of Antibiotic Resistance Genes in a Small Township Wastewater Treatment Plant and the Receiving River
    Chen, M. X.
    Zhang, Y. Q.
    Chang, J. L.
    Ma, X. G.
    Lei, T.
    Yang, J.
    Jiang, T.
    4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ENGINEERING AND SUSTAINABLE DEVELOPMENT (CEESD 2019), 2020, 435
  • [28] Occurrence and prevalence of antibiotic resistance genes and pathogens in an industrial park wastewater treatment plant
    Wu, Yongyi
    Gong, Zhourui
    Wang, Shuijing
    Song, Liyan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 880
  • [29] Mitigation via physiochemically enhanced primary treatment of antibiotic resistance genes in influent from a municipal wastewater treatment plant
    Choi, Sangki
    Shin, Jingyeong
    Chae, Kyu-Jung
    Kim, Young Mo
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 247 (247)
  • [30] Monitoring the exposure and emissions of antibiotic resistance: Co-occurrence of antibiotics and resistance genes in wastewater treatment plants
    Steenbeek, Ruud
    Timmers, Peer H. A.
    van der Linde, Danielle
    Hup, Kay
    Hornstra, Luc
    Been, Frederic
    JOURNAL OF WATER AND HEALTH, 2022, 20 (08) : 1157 - 1170