Diagnostic Accuracy of the Spectralis and Cirrus Reference Databases in Differentiating between Healthy and Early Glaucoma Eyes

被引:30
作者
Silverman, Anna L. [1 ,2 ]
Hammel, Naama [1 ]
Khachatryan, Naira [1 ]
Sharpsten, Lucie [1 ]
Medeiros, Felipe A. [1 ]
Girkin, Christopher A. [3 ]
Liebmann, Jeffrey M. [4 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
[2] George Washington Univ, Sch Med & Hlth Sci, Washington, DC 20052 USA
[3] Univ Alabama Birmingham, Sch Med, Birmingham, AL USA
[4] Columbia Univ, Med Ctr, Harkness Eye Inst, New York, NY USA
基金
美国国家卫生研究院;
关键词
OPTICAL COHERENCE TOMOGRAPHY; FIBER LAYER THICKNESS; AFRICAN DESCENT; DOMAIN OCT; PERFORMANCE; PROGRESSION; RACE; AGE;
D O I
10.1016/j.ophtha.2015.09.047
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate and compare the diagnostic accuracy of global and sector analyses for detection of early visual field (VF) damage using the retinal nerve fiber layer (RNFL) reference databases of the Spectralis (Heidelberg Engineering, Heidelberg, Germany) and Cirrus (Carl Zeiss Meditec, Dublin, CA) spectral-domain optical coherence tomography (SD OCT) devices. Methods: Healthy subjects and glaucoma suspects from the Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES) with at least 2 years of follow-up were included. Global and sectoral RNFL measures were classified as within normal limits, borderline (BL), and outside normal limits (ONL) on the basis of the device reference databases. The sensitivity of ONL classification was estimated in glaucoma suspect eyes that developed repeatable VF damage. Results: A total of 353 glaucoma suspect eyes and 279 healthy eyes were included. A total of 34 (9.6%) of the glaucoma suspect eyes developed VF damage. In glaucoma suspect eyes, Spectralis and Cirrus ONL classification was present in 47 eyes (13.3%) and 24 eyes (6.8%), respectively. The sensitivity of the global RNFL ONL classification among eyes that developed VF damage was 23.5% for Cirrus and 32.4% for Spectralis. The specificity of within-normal-limits global classification in healthy eyes was 100% for Cirrus and 99.6% for Spectralis. There was moderate to substantial agreement between Cirrus and Spectralis classification as ONL. Conclusions: The Spectralis and Cirrus reference databases have a high specificity for identifying healthy eyes and good agreement for detection of eyes with early glaucoma damage. (C) 2016 by the American Academy of Ophthalmology.
引用
收藏
页码:408 / 414
页数:7
相关论文
共 24 条
[11]   Effect of Race, Age, and Axial Length on Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD-OCT [J].
Knight, O'Rese J. ;
Girkin, Christopher A. ;
Budenz, Donald L. ;
Durbin, Mary K. ;
Feuer, William J. .
ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (03) :312-318
[12]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[13]   Agreement Among Spectral-Domain Optical Coherence Tomography Instruments for Assessing Retinal Nerve Fiber Layer Thickness [J].
Leite, Mauro T. ;
Rao, Harsha L. ;
Weinreb, Robert N. ;
Zangwill, Linda M. ;
Bowd, Christopher ;
Sample, Pamela A. ;
Tafreshi, Ali ;
Medeiros, Felipe A. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (01) :85-92
[14]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[15]   Retinal Nerve Fiber Layer Imaging with Spectral-domain Optical Coherence Tomography Patterns of Retinal Nerve Fiber Layer Progression [J].
Leung, Christopher Kai-Shun ;
Yu, Marco ;
Weinreb, Robert N. ;
Lai, Gilda ;
Xu, Guihua ;
Lam, Dennis Shun-Chiu .
OPHTHALMOLOGY, 2012, 119 (09) :1858-1866
[16]   Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Variability and Diagnostic Performance Study [J].
Leung, Christopher Kai-shun ;
Cheung, Carol Yim-lui ;
Weinreb, Robert N. ;
Qiu, Quanliang ;
Liu, Shu ;
Li, Haitao ;
Xu, Guihua ;
Fan, Ning ;
Huang, Lina ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2009, 116 (07) :1257-1263
[17]   Comparison of Different Spectral Domain OCT Scanning Protocols for Diagnosing Preperimetric Glaucoma [J].
Lisboa, Renato ;
Paranhos, Augusto, Jr. ;
Weinreb, Robert N. ;
Zangwill, Linda M. ;
Leite, Mauro T. ;
Medeiros, Felipe A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) :3417-3425
[18]   The Relationship between Visual Field Index and Estimated Number of Retinal Ganglion Cells in Glaucoma [J].
Marvasti, Amir H. ;
Tatham, Andrew J. ;
Zangwill, LindaM. ;
Girkin, Christopher A. ;
Liebmann, JeffreyM. ;
Weinreb, Robert N. ;
Medeiros, Felipe A. .
PLOS ONE, 2013, 8 (10)
[19]   The Structure and Function Relationship in Glaucoma: Implications for Detection of Progression and Measurement of Rates of Change [J].
Medeiros, Felipe A. ;
Zangwill, Linda M. ;
Bowd, Christopher ;
Mansouri, Kaweh ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (11) :6939-6946
[20]   African Descent and Glaucoma Evaluation Study (ADAGES) III. Ancestry Differences in Visual Function in Healthy Eyes [J].
Racette, Lyne ;
Liebmann, Jeffrey M. ;
Girkin, Christopher A. ;
Zangwill, Linda M. ;
Jain, Sonia ;
Becerra, Lida M. ;
Medeiros, Felipe A. ;
Bowd, Christopher ;
Weinreb, Robert N. ;
Boden, Catherine ;
Sample, Pamela A. .
ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (05) :551-559