Development and validation of a stable-isotope dilution liquid chromatography-tandem mass spectrometry method for the determination of bisphenols in ready-made meals

被引:52
|
作者
Regueiro, Jorge [1 ]
Wenzl, Thomas [1 ]
机构
[1] Commiss European Communities, Directorate Gen Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
Bisphenols; BPA; BPF; BPS; Food; Ready-made meal; SOLID-PHASE EXTRACTION; POLYCHLORINATED-BIPHENYLS; ANALOGS; DERIVATIVES; OPTIMIZATION; ALKYLPHENOLS; QUECHERS;
D O I
10.1016/j.chroma.2015.08.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Due to their growing consumption, ready-made meals are a major dietary component for many people in today's society, representing an important potential route of human exposure to several food contaminants. The recent restrictions in the use of bisphenol A have led the plastic industry to look for alternative chemicals, most of them belonging to the same family of p,p'-bisphenols. The aim of the current work was to develop and validate a method based on stable-isotope dilution liquid chromatography-tandem mass spectrometry for the analysis of bisphenol A and its main analogs bisphenol 5, 4,4'-sulfonylbis(2-methylphenol), bisphenol F, bisphenol E, bisphenol B, bisphenol Z, bisphenol AF, bisphenol AP, tetrabromobisphenol A and bisphenol P - in solid foodstuffs, and particularly in ready-made meals. Extraction was carried out by ultrasound-assisted extraction after sample disruption with sand. A selective solid-phase extraction procedure was then applied to reduce potential matrix interferences. Derivatization of bisphenols with pyridine-3-sulfonyl chloride increased their ionization efficiency by electrospray ionization. Validation of the proposed method was performed in terms of selectivity, matrix effects, linearity, precision, measurement uncertainty, trueness and limits of detection. Satisfactory repeatability and intermediate precision were obtained; the related relative standard deviations were <= 7.8% and <= 10%, respectively. The relative expanded uncertainty (k=2) was below 17% for all bisphenol analogs and the trueness of the method was demonstrated by spike recovery experiments. Low limits of detection, in the range from 0.025 mu g kg(-1) to 0.140 mu g kg(-1), were obtained for all compounds. To demonstrate the applicability of the proposed method, it was eventually applied to several ready-made meals purchased from different supermarkets in Belgium. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license
引用
收藏
页码:110 / 121
页数:12
相关论文
共 50 条
  • [41] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of ε-acetamidocaproic acid in rat plasma
    Kim T.H.
    Choi Y.S.
    Choi Y.H.
    Kim Y.G.
    Toxicological Research, 2013, 29 (3) : 203 - 209
  • [42] Development of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Sulfite in Food
    Robbins, Katherine S.
    Shah, Romina
    MacMahon, Shaun
    de Jager, Lowri S.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (21) : 5126 - 5132
  • [43] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of temozolomide in mouse brain tissue
    Kakarla, Raghavi
    Yacoub, Kimberly
    Bearden, Rebecca L.
    Zhou, Aimin
    Mukherjee, Sanjib
    Shan, Frank Y.
    Guo, Baochuan
    SEPARATION SCIENCE PLUS, 2023, 6 (04)
  • [44] Development and validation of a method for quantitative determination of valsartan in human plasma by liquid chromatography-tandem mass spectrometry
    Koseki, Nozomu
    Kawashita, Hiroto
    Hara, Hisanori
    Niina, Miyuki
    Tanaka, Makoto
    Kawai, Ryosei
    Nagae, Yusuke
    Masuda, Naoki
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1769 - 1774
  • [45] Bioanalytical method development and validation of a liquid chromatography-tandem mass spectrometry method for determination of β-lapachone in human plasma
    Putnam, William C.
    Kallem, Raja Reddy
    Subramaniyan, Indhumathy
    Beg, M. Shaalan
    Edpuganti, Vindhya
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188
  • [46] Quantification of blood folate forms using stable-isotope dilution ultra performance liquid chromatography tandem mass spectrometry
    Kirsch, Susanne H.
    Herrmann, Wolfgang
    Obeid, Rima
    ADVANCES IN CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, : 91 - 94
  • [47] Feasibility of Utilizing Stable-Isotope Dimethyl Labeling in Liquid Chromatography-Tandem Mass Spectrometry-Based Determination for Food AllergensCase of Kiwifruit
    Shih, Yi-Chen
    Hsiao, Jhih-Ting
    Sheu, Fuu
    MOLECULES, 2019, 24 (10)
  • [48] QUANTIFICATION OF BLOOD FOLATE FORMS USING STABLE-ISOTOPE DILUTION ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY
    Kirsch, S. H.
    Herrmann, W.
    Obeid, R.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S763 - S763
  • [49] Stable Isotope Dilution Multidimensional Liquid Chromatography-Tandem Mass Spectrometry for Pancreatic Cancer Serum Biomarker Discovery
    Yu, Kenneth H.
    Barry, Colin G.
    Austin, David
    Busch, Christine M.
    Sangar, Vineet
    Rustgi, Anil K.
    Blair, Ian A.
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (03) : 1565 - 1576
  • [50] Application of stable isotope dilution assays based on liquid chromatography-tandem mass spectrometry for the assessment of folate bioavailability
    Rychlik, M
    Netzel, M
    Pfannebecker, I
    Frank, T
    Bitsch, I
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 167 - 176