Due to their growing consumption, ready-made meals are a major dietary component for many people in today's society, representing an important potential route of human exposure to several food contaminants. The recent restrictions in the use of bisphenol A have led the plastic industry to look for alternative chemicals, most of them belonging to the same family of p,p'-bisphenols. The aim of the current work was to develop and validate a method based on stable-isotope dilution liquid chromatography-tandem mass spectrometry for the analysis of bisphenol A and its main analogs bisphenol 5, 4,4'-sulfonylbis(2-methylphenol), bisphenol F, bisphenol E, bisphenol B, bisphenol Z, bisphenol AF, bisphenol AP, tetrabromobisphenol A and bisphenol P - in solid foodstuffs, and particularly in ready-made meals. Extraction was carried out by ultrasound-assisted extraction after sample disruption with sand. A selective solid-phase extraction procedure was then applied to reduce potential matrix interferences. Derivatization of bisphenols with pyridine-3-sulfonyl chloride increased their ionization efficiency by electrospray ionization. Validation of the proposed method was performed in terms of selectivity, matrix effects, linearity, precision, measurement uncertainty, trueness and limits of detection. Satisfactory repeatability and intermediate precision were obtained; the related relative standard deviations were <= 7.8% and <= 10%, respectively. The relative expanded uncertainty (k=2) was below 17% for all bisphenol analogs and the trueness of the method was demonstrated by spike recovery experiments. Low limits of detection, in the range from 0.025 mu g kg(-1) to 0.140 mu g kg(-1), were obtained for all compounds. To demonstrate the applicability of the proposed method, it was eventually applied to several ready-made meals purchased from different supermarkets in Belgium. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license
引用
收藏
页码:110 / 121
页数:12
相关论文
共 50 条
  • [1] Rapid Determination of Bisphenols in Fruits and Vegetables by QuEChERS-Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Zhao Bin
    Tan Xue-Kong
    Fu Yu
    Xue Ming
    Xu Dong-Hai
    Liang Xiu-Chuan
    Zhang Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (05) : 810 - 818
  • [2] Determination of 26 bisphenols in dust by ultra performance liquid chromatography-tandem mass spectrometry
    Sun Jialin
    Niu Yumin
    Gao Qun
    Zhang Jing
    Shao Bing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (05) : 417 - 425
  • [3] Analysis of alkylphenols and bisphenols in soils using liquid chromatography-tandem mass spectrometry
    Pernic, Marek
    Lesniakova, Romana
    Dolezalova, Denisa
    Simek, Zdenek
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 101 (09) : 1287 - 1301
  • [4] Development and validation of a method for determination of corticosteroids in pig fat using liquid chromatography-tandem mass spectrometry
    Toelgyesi, Adam
    Sharma, Virender K.
    Fekete, Jeno
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 403 - 410
  • [5] Determination of anthraquinone in tea by stable isotope dilution assay-gas chromatography-tandem mass spectrometry
    Xie, Wen
    Huang, Chaoqun
    Hong, Deng
    Hou, Jianbo
    Deng, Xiaojun
    Han, Chao
    SN APPLIED SCIENCES, 2020, 2 (06):
  • [6] Development and validation of an ultra performance liquid chromatography-tandem mass spectrometry method for twelve bisphenol compounds in animal feed
    Wang, Ruiguo
    Dong, Shujun
    Wang, Peilong
    Li, Tong
    Huang, Yuan
    Zhao, Lijuan
    Su, Xiaoou
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1178
  • [7] Determination of fipronil and its metabolites in feeds by stable isotope dilution ultra high performance liquid chromatography-tandem mass spectrometry
    Zhou Peng
    Huang Qian
    Ouyang Liqun
    Wang Zheng
    Meng Peng
    Dai Ming
    Wang Ying
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (07) : 629 - 633
  • [8] Determination of bisphenol A, triclosan and their metabolites in human urine using isotope-dilution liquid chromatography-tandem mass spectrometry
    Provencher, Gilles
    Berube, Rene
    Dumas, Pierre
    Bienvenu, Jean-Francois
    Gaudreau, Eric
    Belanger, Patrick
    Ayotte, Pierre
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1348 : 97 - 104
  • [9] Quantification of estrogens in infant formulas by isotope dilution liquid chromatography-tandem mass spectrometry
    Liu, Shuan
    Li, Xiaomin
    Zhao, Yingchen
    Yin, Xiong
    Zhang, Qinghe
    Li, Xiuqin
    Tang, Guangshi
    Li, Hongmei
    ANALYTICAL METHODS, 2018, 10 (32) : 3968 - 3975
  • [10] Determination of the Synthetic Antioxidant Ethoxyquin and Its Metabolites in Fish and Fishery Products Using Liquid Chromatography-Fluorescence Detection and Stable-Isotope Dilution Analysis-Liquid Chromatography-Tandem Mass Spectrometry
    Kranawetvogl, Andreas
    Elsinghorst, Paul W.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (23) : 6650 - 6657