Diagnostic performance comparison of the Chartis System and high-resolution computerized tomography fissure analysis for planning endoscopic lung volume reduction

被引:93
作者
Gompelmann, Daniela [1 ,2 ]
Eberhardt, Ralf [1 ,2 ]
Slebos, Dirk-Jan [3 ]
Brown, Matthew S. [4 ]
Abtin, Fereidoun [4 ]
Kim, Hyun J. [4 ]
Holmes-Higgin, Debby [5 ]
Radhakrishnan, Sri [5 ]
Herth, Felix J. F. [1 ,2 ]
Goldin, Jonathan [4 ]
机构
[1] Heidelberg Univ, Thoraxklin, D-69126 Heidelberg, Baden Wurttembe, Germany
[2] Translat Res Ctr Heidelberg, Heidelberg, Germany
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Pulm Dis, Groningen, Netherlands
[4] Univ Calif Los Angeles, Med Ctr, Dept Radiol, Los Angeles, CA 90024 USA
[5] Pulmonx Inc, Redwood City, CA USA
关键词
valve therapy; bronchoscopy and interventional technique; Endoscopic Lung Volume Reduction; collateral ventilation; emphysema; COLLATERAL VENTILATION; SEVERE EMPHYSEMA; VALVES;
D O I
10.1111/resp.12253
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and objective Endobronchial valve (EBV) therapy is optimized in patients who demonstrate little or no collateral ventilation (CV). The accuracy of the Chartis System and visual assessment of high-resolution computerized tomography (HRCT) fissure completeness by a core radiology laboratory for classifying CV status was compared by evaluating the relationship of each method with target lobe volume reduction (TLVR) after EBV placement. Methods Retrospective HRCT fissure analysis of a study population who underwent catheter-based measurement of CV followed by complete occlusion of the targeted lobe by EBV. Accuracy, sensitivity, specificity, positive predictive value and negative predictive value of the HRCT fissure analysis and the catheter-based measurement of CV for predicting TLVR was determined. Results Accuracy for correctly classifying TLVR with EBV was similar for Chartis System and HRCT fissure analysis (74 vs 77%). The sensitivity and specificity of the Chartis measurement were 86% and 61% and those of HRCT fissure analysis 75% and 79%. Patients with TLVR >= 350 mL had statistically significant improvement in respiratory function, exercise performance and quality of life measures. Conclusions When evaluating patients for likelihood of successful EBV therapy, the Chartis System CV assessment and HRCT fissure analysis appear to have comparable accuracy. Both techniques were found to be beneficial for EBV procedure planning.
引用
收藏
页码:524 / 530
页数:7
相关论文
共 15 条
[1]   Reproducibility of Lung and Lobar Volume Measurements Using Computed Tomography [J].
Brown, Matthew S. ;
Kim, Hyun J. ;
Abtin, Fereidoun ;
Da Costa, Irene ;
Pais, Richard ;
Ahmad, Shama ;
Angel, Erin ;
Ni, Chiayi ;
Kleerup, Eric C. ;
Gjertson, David W. ;
McNitt-Gray, Michael F. ;
Goldin, Jonathan G. .
ACADEMIC RADIOLOGY, 2010, 17 (03) :316-322
[2]   Collateral ventilation [J].
Cetti, EJ ;
Moore, AJ ;
Geddes, DM .
THORAX, 2006, 61 (05) :371-373
[3]   Collateral ventilation, the bane of bronchoscopic volume reduction [J].
Fesslep, HE .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (05) :423-424
[4]   Collateral Ventilation [J].
Gompelmann, D. ;
Eberhardt, R. ;
Herth, F. J. F. .
RESPIRATION, 2013, 85 (06) :515-520
[5]   Predicting Atelectasis by Assessment of Collateral Ventilation prior to Endobronchial Lung Volume Reduction: A Feasibility Study [J].
Gompelmann, D. ;
Eberhardt, R. ;
Michaud, G. ;
Ernst, A. ;
Herth, F. J. F. .
RESPIRATION, 2010, 80 (05) :419-425
[6]  
HAYHURST MD, 1984, LANCET, V2, P320
[7]   Radiological and clinical outcomes of using Chartis™ to plan endobronchial valve treatment [J].
Herth, Felix J. F. ;
Eberhardt, Ralf ;
Gompelmann, Daniela ;
Ficker, Joachim H. ;
Wagner, Manfred ;
Ek, Lars ;
Schmidt, Bernd ;
Slebos, Dirk-Jan .
EUROPEAN RESPIRATORY JOURNAL, 2013, 41 (02) :302-308
[8]   Efficacy predictors of lung volume reduction with Zephyr valves in a European cohort [J].
Herth, Felix J. F. ;
Noppen, Marc ;
Valipour, Arschang ;
Leroy, Sylvie ;
Vergnon, Jean-Michel ;
Ficker, Joachim H. ;
Egan, Jim J. ;
Gasparini, Stefano ;
Agusti, Carlos ;
Holmes-Higgin, Debby ;
Ernst, Armin .
EUROPEAN RESPIRATORY JOURNAL, 2012, 39 (06) :1334-1342
[9]   Incomplete fissures in severe emphysematous patients evaluated with MDCT: Incidence and interobserver agreement among radiologists and pneumologists [J].
Koenigkam-Santos, Marcel ;
Puderbach, Michael ;
Gompelmann, Daniela ;
Eberhardt, Ralf ;
Herth, Felix ;
Kauczor, Hans-Ulrich ;
Heussel, Claus Peter .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :4161-4166
[10]   Technical Advances Measurement of Collateral Flow in the Lung With a Dedicated Endobronchial Catheter System [J].
Mantri, Surag ;
Macaraeg, Chris ;
Shetty, Sujith ;
Aljuri, Nikolai ;
Freitag, Lutz ;
Herth, Felix ;
Eberhardt, Ralf ;
Ernst, Armin .
JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2009, 16 (02) :141-144