Fire resistance of ultra-high performance strain hardening cementitious composite: Residual mechanical properties and spalling resistance

被引:78
作者
Liu, Jin-Cheng [1 ]
Tan, Kang Hai [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
Strain hardening; High temperature; Mechanical properties; Explosive spalling; PE fibers; Microcracks; HIGH-STRENGTH CONCRETE; ELEVATED-TEMPERATURES; PVA FIBER; FLY-ASH; BEHAVIOR; SHCC; PERMEABILITY; BEAMS;
D O I
10.1016/j.cemconcomp.2018.02.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ultra high performance strain hardening cementitious composites (UHP-SHCC) is a special type of cement-based composite material with outstanding mechanical and protective performance at room temperature. But its fire performance is unknown and there is a lack of research in this aspect. This study presents an experimental program to study fire resistance of UHP-SHCC under two aspects, viz. high-temperature explosive spalling resistance and residual mechanical performance after a fire. Both compressive strength and tensile strength of UHP-SHCC were found to deteriorate with increasing exposure temperature. Tensile strain-hardening feature of UHP-SHCC would be lost at 200 degrees C and above. It was found that PE fibers are found not effective in mitigating explosive spalling, although they start to melt at 144 degrees C. FE-SEM (Field Emission Scanning Electron Microscopy) and EDX (Energy Dispersive X-ray) techniques were used to study the state of fiber, fiber/matrix interaction, and microcracks development. Microscopic study found that melted PE fibers were still present in the cementitious matrix, and the melting did not introduce more microcracks. Furthermore, it was difficult for melted PE fibers to diffuse through the matrix, thus providing the reason that PE fibers did not mitigate explosive spalling in UHPSHCC. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 75
页数:14
相关论文
共 33 条
[1]  
[Anonymous], P 1 INT WORKSH CONCR
[2]  
[Anonymous], 2004, 122004 BEN
[3]   Evaluation of the efficiency of UHP-SHCC beams in flexure under external prestressing (comparative study) [J].
Atta, Ahmed .
MAGAZINE OF CONCRETE RESEARCH, 2012, 64 (01) :43-54
[4]   Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures [J].
Behnood, Ali ;
Ghandehari, Masoud .
FIRE SAFETY JOURNAL, 2009, 44 (08) :1015-1022
[5]   Effect of sustained tensile loading on SHCC crack widths [J].
Boshoff, William P. ;
Adendorff, Christo J. .
CEMENT & CONCRETE COMPOSITES, 2013, 37 :119-125
[6]   Permeability measurement on high strength concrete without and with polypropylene fibers at elevated temperatures using a new test setup [J].
Bosnjak, Josipa ;
Ozbolt, Josko ;
Hahn, Rolf .
CEMENT AND CONCRETE RESEARCH, 2013, 53 :104-111
[7]   Composite properties of high-strength polyethylene fiber-reinforced cement and cementless composites [J].
Choi, Jeong-Il ;
Song, Keum-Il ;
Song, Jin-Kyu ;
Lee, Bang Yeon .
COMPOSITE STRUCTURES, 2016, 138 :116-121
[8]   Fibers and fiber cocktails to improve fire resistance of concrete [J].
Czoboly, Oliver ;
Lubloy, Eva ;
Hlavicka, Viktor ;
Balazs, Gyorgy L. ;
Keri, Orsolya ;
Szilagyi, Imre Miklos .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2017, 128 (03) :1453-1461
[9]   Specimen size effect on the residual properties of engineered cementitious composites subjected to high temperatures [J].
Erdem, Tahir Kemal .
CEMENT & CONCRETE COMPOSITES, 2014, 45 :1-8
[10]   Limits of spalling of fire-exposed concrete [J].
Hertz, KD .
FIRE SAFETY JOURNAL, 2003, 38 (02) :103-116