Transient Monitoring Function-Based Fault Detection for Inverter-Interfaced Microgrids

被引:79
作者
Sadeghkhani, Iman [1 ]
Golshan, Mohamad Esmail Hamedani [1 ]
Mehrizi-Sani, Ali [2 ,3 ]
Guerrero, Josep M. [4 ]
Ketabi, Abbas [5 ]
机构
[1] Isfahan Univ Technol, Dept Elect & Comp Engn, Esfahan 8415683111, Iran
[2] Washington State Univ, Energy Syst Innovat Ctr, Pullman, WA 99164 USA
[3] Washington State Univ, Sch Elect Engn & Comp Sci, Pullman, WA 99164 USA
[4] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
[5] Univ Kashan, Dept Elect Engn, Kashan 8731751167, Iran
关键词
Current limiting; distributed energy resources (DER); fault detection; inverter; microgrid; reference frame; transient monitoring function (TMF); voltage-sourced converter (VSC); PROTECTION STRATEGY; SCHEME; OPERATION; FEEDERS;
D O I
10.1109/TSG.2016.2606519
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
One of the major challenges in protection of the inverter-interfaced islanded microgrids is their limited fault current level. This degrades the performance of traditional over-current protection schemes. This paper proposes a fault detection strategy based on monitoring the transient response of the inverter current waveform using a transient monitoring function. To enhance the ability of the proposed fault detection scheme, an auxiliary control system is employed in addition to the main control system of the inverter. The proposed scheme can also differentiate asymmetrical and symmetrical fault conditions from normal load switching events and is effective for various inverter topologies (i.e., three/four-leg), main current limiting strategies, and all reference frames of the multi-loop control system. The merits of the proposed fault detection scheme are demonstrated through several time-domain simulation case studies using the CIGRE benchmark low voltage microgrid network.
引用
收藏
页码:2097 / 2107
页数:11
相关论文
共 30 条
[1]  
Al-Nasseri H, 2008, 2008 12TH INTERNATIONAL MIDDLE EAST POWER SYSTEM CONFERENCE, VOLS 1 AND 2, P371
[2]  
[Anonymous], 2005, P CIGRE S POW SYST D
[3]  
[Anonymous], 50003024 CAL EN COMM
[4]  
[Anonymous], 2014, IEEE Std 519-2014, P1
[5]  
[Anonymous], 2009, COMPUTER RELAYING PO
[6]  
[Anonymous], 2007, 19 INT C EL DISTR
[7]   Fault analysis on distribution feeders with distributed generators [J].
Baran, ME ;
El-Markaby, I .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1757-1764
[8]   Comparison of Current-Limiting Strategies During Fault Ride-Through of Inverters to Prevent Latch-Up and Wind-Up [J].
Bottrell, Nathaniel ;
Green, Timothy C. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (07) :3786-3797
[9]   Fault Location in Power Distribution System With Penetration of Distributed Generation [J].
Brahma, Sukumar M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) :1545-1553
[10]   A Differential Sequence Component Protection Scheme for Microgrids With Inverter-Based Distributed Generators [J].
Casagrande, E. ;
Woon, W. L. ;
Zeineldin, H. H. ;
Svetinovic, D. .
IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (01) :29-37