EFFECTS OF LOW-INTENSITY PULSED ULTRASOUND FOR PREVENTING JOINT STIFFNESS IN IMMOBILIZED KNEE MODEL IN RATS

被引:18
|
作者
Itaya, Nobuyuki [1 ]
Yabe, Yutake [1 ]
Hagiwara, Yoshihiro [1 ]
Kanazawa, Kenji [2 ]
Koide, Masashi [3 ]
Sekiguchi, Takuya [1 ]
Yoshida, Shinichirou [1 ]
Sogi, Yasuhito [1 ]
Yano, Toshihisa [1 ]
Tsuchiya, Masahiro [4 ]
Saijo, Yoshihumi [5 ]
Itoi, Eiji [1 ]
机构
[1] Tohoku Univ, Sch Med, Dept Orthopaed Surg, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
[2] Iwate Prefectural Cent Hosp, Dept Orthopaed Surg, Morioka, Iwate, Japan
[3] Matsuda Hosp, Dept Orthopaed Surg, Izumi Ku, Sendai, Miyagi, Japan
[4] Tohoku Fukushi Univ, Aoba Ku, Sendai, Miyagi, Japan
[5] Tohoku Univ, Grad Sch Biomed Engn, Dept Biomed Imaging, Aoba Ku, Sendai, Miyagi, Japan
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 06期
基金
日本学术振兴会;
关键词
Joint immobilization; Low-intensity pulsed ultrasound; LIPUS; Joint stiffness; Joint contracture; Adhesion; Inflammation; Hypoxia; Fibrosis; Elasticity; TISSUE GROWTH-FACTOR; CAPSULE MATRIX TURNOVER; SPINAL-CORD-INJURY; CONNECTIVE-TISSUE; IN-VITRO; CONTRACTURE FORMATION; SYNOVIAL ADHESIONS; COLLAGEN TYPES; RABBIT MODEL; EXPRESSION;
D O I
10.1016/j.ultrasmedbio.2018.02.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to examine the effect of low-intensity pulsed ultrasound (LIPUS) in preventing joint stiffness. Unilateral knee joints were immobilized in two groups of rats (n = 6/period/getup). Under general anesthesia, the immobilized knee joints were exposed to LIPUS for 20 min/d, 5 d/wk, using an existing LIPUS device (LIPUS group, 1.5-MHz frequency, 1.0-kHz repetition cycle, 200-mu s burst width and 30-mW/cm(2) power output) until endpoints (2, 4 or 6 wk). In the control group, general anesthesia alone was administered in the same manner as in the other group. The variables compared between the groups included joint angles; histologic, histomorphometric and immunohistochemical analyses; quantitative reverse transcription polymerase chain reactions; and tissue elasticity. LIPUS had a preventive effect on joint stiffness, resulting in decreased adhesion, fibrosis and inflammation and hypoxic response after joint immobilization. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1244 / 1256
页数:13
相关论文
共 50 条
  • [1] PREVENTING EFFECTS OF JOINT CONTRACTURE BY LOW-INTENSITY PULSED ULTRASOUND IN A RAT IMMOBILIZED KNEE MODEL
    Itaya, N.
    Hagiwara, Y.
    Tsuchiya, M.
    Yabe, Y.
    Kanazawa, K.
    Koide, M.
    Sekiguchi, T.
    Yoshida, S.
    Yano, T.
    Sogi, Y.
    Itoi, E.
    OSTEOARTHRITIS AND CARTILAGE, 2017, 25 : S89 - S90
  • [2] The effects of low-intensity pulsed ultrasound on preventing the disuse osteoporosis in rats
    Liu, M. Q.
    Guo, X.
    Wang, X. Y.
    Kwong, K. S. C.
    Qian, M. Z.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S136 - S137
  • [3] Effects of Different Low-Intensity Pulsed Ultrasound Intensities and Durations on a Post-Traumatic Knee Joint Contracture Model in Rats
    Nakahara, Ryo
    Ito, Akira
    Nagai-Tanima, Momoko
    Tai, Chia
    Zhao, Zixi
    Xu, Shixuan
    Miyamoto, Fumika
    Abiko, Sachiko
    Aoyama, Tomoki
    Kuroki, Hiroshi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (02): : 396 - 401
  • [4] Low-intensity pulsed ultrasound effects on a bone model of ovariectomized female rats
    Rodrigues, MES
    Kodama, AC
    Rollo, JMDA
    Nascimento, APC
    Malosso, TG
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S117 - S117
  • [5] The Effect of Low-Intensity Pulsed Ultrasound on Temporomandibular Joint Arthritis in Juvenile Rats
    Crossman, Jacqueline
    Lai, Hollis
    Kulka, Marianna
    Jomha, Nadr
    Flood, Patrick
    El-Bialy, Tarek
    TISSUE ENGINEERING PART A, 2024, 30 (23-24) : 740 - 751
  • [6] Effects of low-intensity pulsed ultrasound exposure on rats tibia periosteum
    Batista, Jaqueline M.
    Nakagaki, Wilson R.
    Soares, Evelise A.
    Camilli, Josse A.
    ANAIS DA ACADEMIA BRASILEIRA DE CIENCIAS, 2020, 92 (01):
  • [7] Effects of Low-Intensity Pulsed Ultrasound on Implant Osseointegration in Ovariectomized Rats
    Zhou, Hongbo
    Hou, Yongfu
    Zhu, Zhimin
    Xiao, Weixiong
    Xu, Qian
    Li, Lei
    Li, Xin
    Chen, Wenchuan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (04) : 747 - 754
  • [8] Low-intensity pulsed ultrasound: Effects on nonunions
    Gebauer, D
    Mayr, E
    Orthner, E
    Ryaby, JP
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (10): : 1391 - 1402
  • [9] Effects of millimeter-wave for preventing joint stiffness in the immobilized knee rat model
    Shui, Xiao-ping
    Ye, Feng
    Li, Chun-ying
    Zhang, Xin
    Wang, Min-jia
    Li, Bin
    Chen, Ke
    Liao, Ying-ying
    KNEE, 2023, 42 : 236 - 245
  • [10] Pitfalls preventing bone union with EXOGEN Low-Intensity Pulsed Ultrasound
    Hughes, Luke D.
    Khudr, Jamal
    Gee, Edward
    Pillai, Anand
    SICOT-J, 2022, 8