Additional value of integrated PET/CT over PET alone in the initial staging and follow up of head and neck malignancy

被引:24
|
作者
Ishikita, Tomohiro [2 ]
Oriuchi, Noboru [1 ]
Higuchi, Tetsuya [1 ]
Miyashita, Go [2 ]
Arisaka, Yukiko [1 ]
Paudyal, Bishnuhari [1 ]
Paudyal, Pramila [1 ]
Hanaoka, Hirofumi [3 ]
Miyakubo, Mitsuyuki [2 ]
Nakasone, Yoshiki [2 ]
Negishi, Akihide [2 ]
Yokoo, Satoshi [2 ]
Endo, Keigo [1 ]
机构
[1] Gunma Univ, Dept Diagnost Radiol & Nucl Med, Grad Sch Med, Maebashi, Gunma 3718511, Japan
[2] Gunma Univ, Dept Stomatol & Maxillofacial Surg, Grad Sch Med, Maebashi, Gunma 3718511, Japan
[3] Gunma Univ, Dept Bioimaging Informat Anal, Grad Sch Med, Maebashi, Gunma 3718511, Japan
关键词
FDG-PET; PET/CT; Head and neck cancer; Staging; Diagnostic performance; POSITRON-EMISSION-TOMOGRAPHY; SQUAMOUS-CELL CARCINOMA; COMPUTED-TOMOGRAPHY; F-18-FDG PET; CANCER; PERFORMANCE; METASTASES; CT;
D O I
10.1007/s12149-009-0326-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Clinical application of FDG-PET in head and neck cancer includes identification of metastases, unknown primary head and neck malignancy, or second primary carcinoma, and also recurrent tumor after treatment. In this study, the additional value of PET/CT fusion images over PET images alone was evaluated in patients with initial staging and follow up of head and neck malignancy. Forty patients with suspected primary head and neck malignancy and 129 patients with suspected relapse after treatment of head and neck malignancy were included. FDG-PET/CT study was performed after the intravenous administration of FDG (5 MBq/kg). Target of evaluation was set at primary tumor, cervical lymph node, and whole body. PET images and PET with CT fusion images were compared. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results of PET and PET/CT were compared with postoperative histopathological examination, and case by case comparison of PET and PET/CT results for each region was performed. The additional value of CT images over PET only images was assessed. Statistical differences in sensitivity and specificity were evaluated. In the comparative evaluation of 507 targets by PET alone and PET/CT, 401 targets showed agreement of the results. Of the 106 discordant targets, 103 showed a positive result on PET alone and negative result on PET/CT. These results showed a significant difference (p < 0.01). Sensitivity of PET/CT was slightly higher than that of PET without statistical significance, while specificity of PET/CT was significantly higher than that of PET alone (Initial staging: 90.5% vs. 62.2%, p < 0.01; Follow up: 97.2% vs. 74.4%, p < 0.01). In Fisher's direct probability test, a significant difference was noted in the sensitivity (Initial staging: 91.3% vs. 87.0%, p < 0.01; Follow up: 93.9% vs. 91.4%, p < 0.01). Combined PET/CT showed improved diagnostic performance than PET alone by decreasing the number of false positive findings in patients with initial staging and follow up of head and neck malignancy.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [1] Additional value of integrated PET/CT over PET alone in the initial staging and follow up of head and neck malignancy
    Tomohiro Ishikita
    Noboru Oriuchi
    Tetsuya Higuchi
    Go Miyashita
    Yukiko Arisaka
    Bishnuhari Paudyal
    Pramila Paudyal
    Hirofumi Hanaoka
    Mitsuyuki Miyakubo
    Yoshiki Nakasone
    Akihide Negishi
    Satoshi Yokoo
    Keigo Endo
    Annals of Nuclear Medicine, 2010, 24 : 77 - 82
  • [2] The additional value of integrated PET/CT over PET in initial lymph node staging of esophageal cancer
    Kato, Hiroyuki
    Kimura, Hitoshi
    Nakajima, Masanobu
    Sakai, Makoto
    Sano, Akihiko
    Tanaka, Naritaka
    Inose, Takanori
    Faried, Ahmad
    Saito, Kana
    Ieta, Keisuke
    Sohda, Makoto
    Fukai, Yasuyuki
    Miyazaki, Tatsuya
    Masuda, Norihiro
    Fukuchi, Minoru
    Ojima, Hitoshi
    Tsukada, Katsuhiko
    Oriuchi, Noboru
    Endo, Keigo
    Kuwano, Hiroyuki
    ONCOLOGY REPORTS, 2008, 20 (04) : 857 - 862
  • [3] ACCURACY OF WHOLE-BODY PET AND PET-CT IN INITIAL M STAGING OF HEAD AND NECK CANCER: A META-ANALYSIS
    Xu, Guo-Zeng
    Zhu, Xiao-Dong
    Li, Ming-Yao
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2011, 33 (01): : 87 - 94
  • [4] PET/MRI and PET/CT in follow-up of head and neck cancer patients
    Queiroz, Marcelo A.
    Huellner, Martin
    Kuhn, Felix
    Huber, Gerhardt
    Meerwein, Christian
    Kollias, Spyros
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (06) : 1066 - 1075
  • [5] PET/CT and PET/MRI in head and neck malignancy
    Szyszko, T. A.
    Cook, G. J. R.
    CLINICAL RADIOLOGY, 2018, 73 (01) : 60 - 69
  • [6] PET plus MR versus PET/CT in the initial staging of head and neck cancer, using a trimodality PET/CT plus MR system
    Sekine, Tetsuro
    Barbosa, Felipe de Galiza
    Kuhn, Felix P.
    Burger, Irene A.
    Stolzmann, Paul
    Huber, Gerhard F.
    Kollias, Spyros S.
    von Schulthess, Gustav K.
    Veit-Haibach, Patrick
    Huellner, Martin W.
    CLINICAL IMAGING, 2017, 42 : 232 - 239
  • [7] 18F-FDG PET/CT in staging and delineation of radiotherapy volume for head and neck cancer
    Pedraza, S.
    Ruiz-Alonso, A.
    Hernandez-Martinez, A. C.
    Cabello, E.
    Lora, D.
    Perez-Regadera, J. F.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2019, 38 (03): : 154 - 159
  • [8] Comparison of PET-CT, CT and MRI scan in initial staging and management of head and neck cancers
    Ahmad, Shoaib
    Mair, Manish
    Haris, Puteri Abdul
    Haider, Abbas
    Baker, Andrew
    Conboy, Peter
    Walter, Harriet
    Raj, Lakshmiah
    Wright, Simon
    Vaidhyanath, Ram
    Thiagarajan, Sridhar
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 279 (5) : 2651 - 2656
  • [9] Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT
    W. De Wever
    S. Ceyssens
    L. Mortelmans
    S. Stroobants
    G. Marchal
    J. Bogaert
    J. A. Verschakelen
    European Radiology, 2007, 17 : 23 - 32
  • [10] Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT
    De Wever, W.
    Ceyssens, S.
    Mortelmans, L.
    Stroobants, S.
    Marchal, G.
    Bogaert, J.
    Verschakelen, J. A.
    EUROPEAN RADIOLOGY, 2007, 17 (01) : 23 - 32