Retrospective assessment of at-risk myocardium in reperfused acute myocardial infarction patients using contrast-enhanced balanced steady-state free-precession cardiovascular magnetic resonance at 3T with SPECT validation

被引:10
|
作者
Sun, Zheng [1 ]
Zhang, Qiuhang [1 ]
Zhao, Huan [3 ]
Yan, Chengxi [1 ]
Yang, Hsin-Jung [2 ]
Li, Debiao [2 ,4 ]
Li, Kuncheng [1 ]
Liu, Zhi [3 ]
Yang, Qi [1 ]
Dharmakumar, Rohan [2 ,4 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing 100053, Peoples R China
[2] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[3] Capital Med Univ, Xuanwu Hosp, Dept Cardiol, Beijing 100053, Peoples R China
[4] Univ Calif Los Angeles, Dept Med, Los Angeles, CA 90095 USA
基金
国家重点研发计划; 美国国家科学基金会;
关键词
Acute myocardial infarction; Area-at-risk; Cardiovascular magnetic resonance; CE-SSFP; SPECT; DARK-BLOOD; CMR; AREA; SSFP; QUANTIFICATION; PERFUSION; SALVAGE; EDEMA; MRI;
D O I
10.1186/s12968-021-00730-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Contrast-enhanced (CE) steady-state free precession (SSFP) CMR at 1.5T has been shown to be a valuable alternative to T2-based methods for the detection and quantifications of area-at-risk (AAR) in acute myocardial infarction (AMI) patients. However, CE-SSFP's capacity for assessment of AAR at 3T has not been investigated. We examined the clinical utility of CE-SSFP and T2-STIR for the retrospective assessment of AAR at 3T with single-photon-emission-computed tomography (SPECT) validation. Materials and methodsA total of 60 AMI patients (ST-elevation AMI, n = 44; non-ST-elevation AMI, n = 16) were recruited into the CMR study between 3 and 7 days post revascularization. All patients underwent T2-STIR, CE-bSSFP and late-gadolinium-enhancement CMR. For validation, SPECT images were acquired in a subgroup of patients (n=30). Results In 53 of 60 patients (88%), T2-STIR was of diagnostic quality compared with 54 of 60 (90%) with CE-SSFP. In a head-to-head per-slice comparison (n=365), there was no difference in AAR quantified using T2-STIR and CE-SSFP (R-2=0.92, p < 0.001; bias:-0.4 +/- 0.8 cm(2), p=0.46). On a per-patient basis, there was good agreement between CE-SSFP (n=29) and SPECT (R-2=0.86, p < 0.001; bias: - 1.3 +/- 7.8%LV, p=0.39) for AAR determination. T2-STIR also showed good agreement with SPECT for AAR measurement (R-2=0.81, p < 0.001, bias: 0.5 +/- 11.1%LV, p=0.81). There was also a strong agreement between CE-SSFP and T2-STIR with respect to the assessment of AAR on per-patient analysis (R-2=0.84, p < 0.001, bias: - 2.1 +/- 10.1%LV, p=0.31). Conclusions At 3T, both CE-SSFP and T2-STIR can retrospectively quantify the at-risk myocardium with high accuracy.
引用
收藏
页数:11
相关论文
共 44 条
  • [21] Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T
    Alexander Isaak
    Narine Mesropyan
    Christopher Hart
    Shuo Zhang
    Dmitrij Kravchenko
    Christoph Endler
    Christoph Katemann
    Oliver Weber
    Claus C. Pieper
    Daniel Kuetting
    Ulrike Attenberger
    Darius Dabir
    Julian A. Luetkens
    Journal of Cardiovascular Magnetic Resonance, 24
  • [22] Validation of contrast enhanced cine steady-state free precession and T2-weighted CMR for assessment of ischemic myocardial area-at-risk in the presence of reperfusion injury
    Hansen, Esben Sovso Szocska
    Pedersen, Steen Fjord
    Pedersen, Steen Bonlokke
    Botker, Hans Erik
    Kim, Won Yong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (06): : 1039 - 1045
  • [23] Validation of contrast enhanced cine steady-state free precession and T2-weighted CMR for assessment of ischemic myocardial area-at-risk in the presence of reperfusion injury
    Esben Søvsø Szocska Hansen
    Steen Fjord Pedersen
    Steen Bønløkke Pedersen
    Hans Erik Bøtker
    Won Yong Kim
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1039 - 1045
  • [24] Myocardial perfusion Imaging based on the blood oxygen level-dependent effect using T2-prepared steady-state free-precession magnetic resonance Imaging
    Fieno, DS
    Shea, SM
    Li, YZ
    Harris, KR
    Finn, JP
    Li, DB
    CIRCULATION, 2004, 110 (10) : 1284 - 1290
  • [25] Noncontrast 3D steady-state free-precession magnetic resonance angiography of the whole chest using nonselective radiofrequency excitation over a large field of view: Comparison with single-phase 3D contrast-enhanced magnetic resonance angiography
    Krishnam, Mayil S.
    Tomasian, Anderanik
    Deshpande, Vibhas
    Tran, Lien
    Laub, Gerhard
    Finn, J. Paul
    Ruehm, Stefan G.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (06) : 411 - 420
  • [26] Myocardium at risk quantified by contrast enhanced steady-state free precession does not differ in extent or severity when comparing patients with ST-elevation myocardial infarction treated with standard reperfusion or postconditioning
    Peder Sörensson
    Marcus Carlsson
    Martin Ugander
    Håkan Arheden
    John Pernow
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [27] Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Ohno, Tsuyoshi
    Ono, Ayako
    Yamashita, Rikiya
    Arizono, Shigeki
    Kido, Aki
    Sakashita, Naotaka
    Togashi, Kaori
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 32 - 39
  • [28] 3D-assessment of RVOT dimensions prior percutaneous pulmonary valve implantation: comparison of contrast-enhanced magnetic resonance angiography versus 3D steady-state free precession sequence
    Ebel, Sebastian
    Gottschling, Sebastian
    Buzan, Maria T. A.
    Grothoff, Matthias
    Daehnert, Ingo
    Wagner, Robert
    Graefe, Daniel
    Lurz, Philipp
    Gutberlet, Matthias
    Luecke, Christian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (08): : 1453 - 1463
  • [29] 3D-assessment of RVOT dimensions prior percutaneous pulmonary valve implantation: comparison of contrast-enhanced magnetic resonance angiography versus 3D steady-state free precession sequence
    Sebastian Ebel
    Sebastian Gottschling
    Maria T. A. Buzan
    Matthias Grothoff
    Ingo Dähnert
    Robert Wagner
    Daniel Gräfe
    Philipp Lurz
    Matthias Gutberlet
    Christian Lücke
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1453 - 1463
  • [30] CINE BALANCED STEADY-STATE FREE PRECESSION IS A RELIABLE ALTERNATIVE TO CONVENTIONAL T2-WEIGHTED IMAGING AND EVANS BLUE FOR THE CMR ASSESSMENT OF AREA AT RISK AFTER MYOCARDIAL INFARCTION
    Santos-Gallego, Carlos G.
    Vahl, Torsten
    Goliasch, Georg
    Ishikawa, Kiyotake
    Hajjar, Roger J.
    Fuster, Valentin
    Sanz, Javier
    Badimon, Juan Jose
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1076 - E1076