Quantitative characterization of biological liquids for third-harmonic generation microscopy

被引:68
作者
Debarre, Delphine [1 ]
Beaurepaire, Emmanuel [1 ]
机构
[1] Ecole Polytech, Lab Opt & Biosci, CNRS, INSERM, Palaiseau, France
关键词
D O I
10.1529/biophysj.106.094946
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Third-harmonic generation (THG) microscopy provides images of unstained biological samples based on spatial variations in third-order nonlinear susceptibility, refractive index, and dispersion. In this study, we establish quantitative values for the third-order nonlinear susceptibilities of several solvents (water, ethanol, glycerol), physiological aqueous (ions, amino acids, polypeptides, bovine serum albumin, glucose) and lipid (triglycerides, cholesterol) solutions as a function of solute concentration in the 1.05-1.25 mu m excitation range. We use these data in conjunction with imaging experiments to show that THG imaging with similar to 1.2 mm excitation lacks specificity and sensitivity to detect physiological ion concentration changes, and that nonaqueous structures such as lipid bodies provide a more robust source of signal. Finally, we illustrate the impact of index-matching liquids in THG images. These data provide a basis for interpreting biological THG images and for developing additional applications.
引用
收藏
页码:603 / 612
页数:10
相关论文
共 45 条
[1]  
ANGELOVA MI, 1992, PROG COLL POL SCI S, V89, P127
[2]   Nonlinear scanning laser microscopy by third harmonic generation [J].
Barad, Y ;
Eisenberg, H ;
Horowitz, M ;
Silberberg, Y .
APPLIED PHYSICS LETTERS, 1997, 70 (08) :922-924
[3]   Nonlinearity measurements of thin films by third-harmonic-generation microscopy [J].
Barille, R ;
Canioni, L ;
Sarger, L ;
Rivoire, G .
PHYSICAL REVIEW E, 2002, 66 (06) :4
[4]   Visualization of mitochondria in cardiomyocytes by simultaneous harmonic generation and fluorescence microscopy [J].
Barzda, V .
OPTICS EXPRESS, 2005, 13 (20) :8263-8276
[5]   Non-phase-matched optical third-harmonic generation in noncentrosymmetric media: Cascaded second-order contributions for the calibration of third-order nonlinearities [J].
Bosshard, C ;
Gubler, U ;
Kaatz, P ;
Mazerant, W ;
Meier, U .
PHYSICAL REVIEW B, 2000, 61 (16) :10688-10701
[6]  
Boyd R. W., 2003, NONLINEAR OPTICS
[7]   Imaging of Ca2+ intracellular dynamics with a third-harmonic generation microscope [J].
Canioni, L ;
Rivet, S ;
Sarger, L ;
Barille, R ;
Vacher, P ;
Voisin, P .
OPTICS LETTERS, 2001, 26 (08) :515-517
[8]   Wavelength dependent damage in biological multi-photon confocal microscopy:: A micro-spectroscopic comparison between femtosecond Ti:sapphire and Cr:forsterite laser sources [J].
Chen, IH ;
Chu, SW ;
Sun, CK ;
Cheng, PC ;
Lin, BL .
OPTICAL AND QUANTUM ELECTRONICS, 2002, 34 (12) :1251-1266
[9]   Green's function formulation for third-harmonic generation microscopy [J].
Cheng, JX ;
Xie, XS .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2002, 19 (07) :1604-1610
[10]   Multimodal nonlinear spectral microscopy based on a femtosecond Cr:forsterite laser [J].
Chu, SW ;
Chen, IH ;
Liu, TM ;
Chen, PC ;
Sun, CK ;
Lin, BL .
OPTICS LETTERS, 2001, 26 (23) :1909-1911