Research on Measurement Method of Ultrasonic Transit Time based on Automatic Gain Control

被引:0
作者
Ma, Qinyong [1 ,2 ]
Zhang, Yuanzheng [1 ]
机构
[1] Chongqing Res Inst, China Coal Technol & Engn Grp, Chongqing 400039, Peoples R China
[2] State Key Lab Gas Disaster Detecting Preventing &, Chongqing 400039, Peoples R China
来源
PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE | 2020年
关键词
Automatic gain control; Ultrasonic transit time; Adaptive threshold; Zero crossing detection; Flow calibration; SIGNAL-PROCESSING METHOD; THRESHOLD;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to reduce the periodic error in the transit time detection caused by the amplitude jitter, this paper adopts the automatic gain control technology to stabilize the amplitude of received ultrasonic signal, and detect the accurate ultrasonic transit time according to the adaptive threshold method and the zero crossing detection method. The flow calibration experiment is carried out on the self-designed ultrasonic gas flowmeter, the experimental results demonstrate that the measurement accuracy is within +1% and the repeatability is within 0.2%.
引用
收藏
页码:2032 / 2036
页数:5
相关论文
共 12 条
  • [1] High-frequency transducers and correlation method to enhance ultrasonic gas flow metering
    Brassier, P
    Hosten, B
    Vulovic, F
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2001, 12 (03) : 201 - 211
  • [2] The manufacturing of ultrasonic gas flow meters
    Drenthen, JG
    de Boer, G
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2001, 12 (02) : 89 - 99
  • [3] Similarity Judgment-Based Double-Threshold Method for Time-of-Flight Determination in an Ultrasonic Gas Flowmeter
    Fang, Zehua
    Hu, Liang
    Mao, Kai
    Chen, Wenyu
    Fu, Xin
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (01) : 24 - 32
  • [4] Effect of ultrasonic noise generated by pressure control valves on ultrasonic gas flowmeters
    Kang, Woong
    Lee, Saeng-Hee
    Lee, Seung-Jun
    Ha, Young-Cheol
    Jung, Sung-Soo
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 60 : 95 - 104
  • [5] Liu YP, 2007, ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, P534
  • [6] Ultrasonic flowmeters: Half-century progress report, 1955-2005
    Lynnworth, L. C.
    Liu, Yi
    [J]. ULTRASONICS, 2006, 44 : E1371 - E1378
  • [7] Nishiguchi II., 2016, 2016 JAPAN SOC APPL, V2016, P1347
  • [8] Sun SH, 2019, 2019 IEEE 4TH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP 2019), P664, DOI [10.1109/siprocess.2019.8868700, 10.1109/SIPROCESS.2019.8868700]
  • [9] Energy peak fitting of echo based signal processing method for ultrasonic gas flow meter
    Tian, Lei
    Xu, Ke-Jun
    Mu, Li-Bin
    Liu, Bo
    [J]. MEASUREMENT, 2018, 117 : 41 - 48
  • [10] An enrichment method to detect low concentration formaldehyde
    Wang, Jing
    Liu, Li
    Cong, Song-Ying
    Qi, Jin-Qing
    Xu, Bao-Kun
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) : 1010 - 1015