Tactor-Induced Skin Stretch as a Sensory Substitution Method in Teleoperated Palpation

被引:36
作者
Schorr, Samuel B. [1 ]
Quek, Zhan Fan [1 ]
Nisky, Ilana [2 ]
Provancher, William R. [3 ]
Okamura, Allison M. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Ben Gurion Univ Negev, Dept Biomed Engn, IL-8410501 Beer Sheva, Israel
[3] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
基金
美国国家科学基金会;
关键词
Cutaneous feedback; haptic devices; sensory substitution; skin stretch; stiffness perception; FORCE FEEDBACK; HAPTIC PERCEPTION; SURGERY; DISPLAY;
D O I
10.1109/THMS.2015.2463090
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
When we use a tool to explore or manipulate an object, friction between the surface of the tool and the fingerpads generates skin stretch cues that are related to the interaction forces between the tool and the object. In this study, we emulate these naturally occurring skin stretch cues in order to convey force direction and magnitude information to users during teleoperation. We hypothesize that skin stretch feedback is a useful substitute for kinesthetic force feedback in force-sensitive teleoperated tasks. In this study, ten participants performed teleoperated palpation to determine the orientation of a stiff region in a surrounding artificial tissue using five feedback conditions: skin stretch, force, reduced gain force, graphic, and vibration. When participants received skin stretch feedback, they localized the stiff region as well as with force feedback, with no increase in task completion time. Additionally, participants receiving skin-stretch feedback localized the stiff region statistically significantly more accurately than those using vibration feedback. Although participants using skin stretch exhibited higher interaction forces than when using force, vibration, and graphical feedback, skin stretch statistically significantly decreased interaction forces compared with reduced gain force feedback. Thus, skin-stretch feedback is a compelling substitute for force feedback and may be useful in scenarios where force feedback is reduced or infeasible.
引用
收藏
页码:714 / 726
页数:13
相关论文
共 46 条
[1]  
Bark K, 2010, IEEE T HAPTICS, V3, P166, DOI [10.1109/ToH.2010.21, 10.1109/TOH.2010.21]
[2]   THE STRUCTURE AND FUNCTION OF PACINIAN CORPUSCLES - A REVIEW [J].
BELL, J ;
BOLANOWSKI, S ;
HOLMES, MH .
PROGRESS IN NEUROBIOLOGY, 1994, 42 (01) :79-128
[3]  
BENPORQUIS L, 2014, P IEEE HAPT S FEB, P289
[4]   Tangential versus normal displacements of skin: Relative effectiveness for producing tactile sensations [J].
Biggs, J ;
Srinivasan, MA .
10TH SYMPOSIUM ON HAPTIC INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS, PROCEEDINGS, 2002, :121-128
[5]  
Brown JD, 2004, STUD HEALTH TECHNOL, V98, P34
[6]   Auditory Force Feedback Substitution Improves Surgical Precision during Simulated Ophthalmic Surgery [J].
Cutler, Nathan ;
Balicki, Marcin ;
Finkelstein, Mark ;
Wang, Jiangxia ;
Gehlbach, Peter ;
McGready, John ;
Iordachita, Iulian ;
Taylor, Russell ;
Handa, James T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (02) :1316-1324
[7]  
Debus T, 2004, INT J CONTROL AUTOM, V2, P390
[8]  
Dennerlein J. T., 1997, Proceedings of the ASME Dynamic Systems and Control Division, P189
[9]  
Galambos P, 2012, ACTA POLYTECH HUNG, V9, P41
[10]  
Gleeson BT, 2010, IEEE T HAPTICS, V3, P177, DOI [10.1109/TOH.2010.20, 10.1109/ToH.2010.20]