Spatial variation of acoustic parameters in human skin:: An in vitro study between 22 and 45 MHz

被引:15
作者
Lebertre, M
Ossant, F
Vaillant, L
Diridollou, S
Patat, F
机构
[1] Fac Med Tours, LUSSI, FRE 2448, GIP Ultrasons, F-37032 Tours, France
[2] Univ Tours, Bretonneau Hosp, Tours, France
[3] Ctr JL Alibert, Inst Rech Pierre Fabre, Toulouse, France
关键词
attenuation; backscattering coefficient; human; skin heterogeneity; texture analysis; tissue characterization; ultrasound;
D O I
10.1016/S0301-5629(02)00500-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study of spatial variance of acoustic parameters was performed on eight nonfrozen samples of female abdominal skin (women 46.5 +/- 12.2 years old), obtained during plastic surgery. Intra- and interindividual variations are discussed on the basis of estimations of three acoustic parameters (slope of attenuation- beta; integrated attenuation coefficient- IAC; integrated backscattering coefficient- IBC) and one texture parameter (based on two estimators of effective density of scatterers: alpha(2) and alpha(1/2)) as a function of surface area and depth of acquisition in the frequency range 22 to 45 MHz. Values of intraindividual variations varied from 7.1% for IAC to 23.2% for IBC, and significantly decreased at a ratio between 1.2 to 2.3 when the acquisition surface area was increased from 4 mm(2) to 1 cm(2). Interindividual variations were higher than intraindividual variations, and varied from 14.2 % for alpha(1/2) to 51 % for IBC. The mean values (+/- SD) for all specimens combined, estimated with a large number of independent radiofrequency (RF) lines (400) and for a surface area of exploration of 4 cm(2), were 1.06 +/- 0.17 dB cm(-1) MHz(-1) for beta, 135 +/- 37 dB cm(-1) for IAC, (3.7 +/- 1.9) X 10(-2) cm(-1) sr(-1) for IBC, 1.40 +/- 0.17 scatterers/resolution cell for alpha(2) and 1.32 +/- 0.27 scatterers/resolution cell for alpha(1/2). Finally, attenuation mu(f) and backscattering coefficient mu(f) were compared to published results for the same parameters measured inhuman skin. (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:599 / 615
页数:17
相关论文
共 43 条
  • [1] AGACHE P, 2002, HISTOPHYSIOLOGIE DER
  • [2] ALTEMEYER P, 1992, ULTASOUND DERMATOLOG
  • [3] APPLICATION OF AUTOREGRESSIVE SPECTRAL-ANALYSIS FOR ULTRASOUND ATTENUATION ESTIMATION - INTEREST IN HIGHLY ATTENUATING MEDIUM
    BALDEWECK, T
    LAUGIER, P
    HERMENT, A
    BERGER, G
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (01) : 99 - 110
  • [4] OPTIMAL PRECISION IN ULTRASOUND ATTENUATION ESTIMATION AND APPLICATION TO THE DETECTION OF DUCHENNE MUSCULAR-DYSTROPHY CARRIERS
    BERGER, G
    LAUGIER, P
    FINK, M
    PERRIN, J
    [J]. ULTRASONIC IMAGING, 1987, 9 (01) : 1 - 17
  • [5] Correlation of ultrasonic attenuation (30 to 50 mhz) and constituents of atherosclerotic plaque
    Bridal, SL
    Fornes, P
    Bruneval, P
    Berger, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) : 691 - 703
  • [6] Current uses of diagnostic high-frequency US in dermatology
    Cammarota, T
    Pinto, F
    Magliaro, A
    Sarno, A
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 : S215 - S223
  • [7] INVITRO ESTIMATION OF ACOUSTIC PARAMETERS OF THE LIVER AND CORRELATIONS WITH HISTOLOGY
    CLOOSTERMANS, MJTM
    MOL, H
    VERHOEF, WA
    THIJSSEN, JM
    KUBAT, K
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (01) : 39 - 51
  • [8] DAZIEL KL, 1991, CLIN EXP DERMATOL, V16, P315
  • [9] ULTRASONIC SIGNAL-PROCESSING FOR INVIVO ATTENUATION MEASUREMENT - SHORT-TIME FOURIER-ANALYSIS
    FINK, M
    HOTTIER, F
    CARDOSO, JF
    [J]. ULTRASONIC IMAGING, 1983, 5 (02) : 117 - 135
  • [10] DIFFRACTION EFFECTS IN PULSE-ECHO MEASUREMENT
    FINK, MA
    CARDOSO, JF
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1984, 31 (04): : 313 - 329