Development of an innovative external (in air) Particle Induced Gamma-ray Emission method for rapid non-destructive determination of isotopic composition of boron in "As received" boron based ceramic neutron absorbers

被引:7
作者
Raja, Sk Wasim [1 ,4 ]
Sharma, Vishal [2 ]
Samanta, Sudeep Kumar [2 ,4 ]
Acharya, Raghunath [2 ,4 ]
Murthy, Tammana S. R. C. [2 ,3 ,4 ]
Majumdar, Sanjib [3 ,4 ]
Pujari, Pradeep Kumar [2 ,4 ]
机构
[1] BARC, Variable Energy Cyclotron Ctr, Radiochem Div, 1-AF Bidhan Nagar, Kolkata 700064, India
[2] Bhabha Atom Res Ctr, Radiochem Div, Mumbai 400085, India
[3] Bhabha Atom Res Ctr, Mat Proc & Corros Engn Div, Mumbai 400085, India
[4] Homi Bhabha Natl Inst, Dept Atom Energy, Mumbai 400094, India
关键词
Ceramic neutron absorber; Boron carbide; Isotopic composition; As received sample; PIGE; External (in air) proton beam; ELEMENT ANALYSIS; ICP-MS; PIGE; CARBIDE; QUANTIFICATION; DENSIFICATION; IMPROVEMENTS; ORIGIN; RATIOS;
D O I
10.1016/j.aca.2022.339686
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Boron is an important element in nuclear reactor technology due to its high neutron absorption cross section of B-10 isotope. Isotopic composition of B (IC, B-10/B-11 atom ratio) determination in finished neutron absorbers is a necessity under chemical quality control (CQC). We report an innovative greener method for rapid and non-destructive approach of isotopic composition determination of B in "as received " boron based ceramic neutron absorbers including boron carbides and hexa-borides by external (in air) Particle Induced Gamma-ray Emission (PIGE) using 3.5 MeV proton beam. It involves irradiation of "as received " powder samples wrapped in a thin Mylar film and measurement of prompt gamma rays at 429, 718 and 2125 keV from B-10(p,alpha gamma)Be-7, B-10(p,p'gamma)B-10 and B-11(p,p'gamma)B-11, respectively, using a HPGe detector system. The method was standardized with natural and enriched B4C powders. For validation, the results of isotopic composition obtained from "as received " samples were compared with that obtained from pellet samples using both external and vacuum chamber PIGE methods. IC values obtained for natural to B-10 enriched samples (19.8-67 atom % of( 10)B) are very encouraging with 1-2% and 0.3-0.7% uncertainties from single and replicate sample experiments. The method is truly non-destructive as the samples can be returned back as such after the experiment as they are not radioactive. Compared to existing PIGE method for isotopic composition of B, the developed method keeps promise for wide applications as it is simple, sensitive and rapid and it does not require vacuum, pellet preparation with a binder, exact mass of the sample and beam current measurement.(C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 43 条
[1]   Non-destructive quantification of total boron and its isotopic composition in boron based refractory materials by PIGE and an inter-comparison study using TIMS and titrimetry [J].
Acharya, R. ;
Raja, Sk Wasim ;
Chhillar, Sumit ;
Gupta, J. ;
Sonber, J. K. ;
Murthy, T. S. R. C. ;
Bhushan, K. Sasi ;
Rao, Radhika M. ;
Majumdar, S. ;
Pujari, P. K. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) :784-791
[2]   Precise and accurate determination of boron isotope ratios by multiple collector ICP-MS: origin of boron in the Ngawha geothermal system, New Zealand [J].
Aggarwal, JK ;
Sheppard, D ;
Mezger, K ;
Pernicka, E .
CHEMICAL GEOLOGY, 2003, 199 (3-4) :331-342
[3]   BORON ISOTOPE ANALYSIS - A REVIEW [J].
AGGARWAL, JK ;
PALMER, MR .
ANALYST, 1995, 120 (05) :1301-1307
[4]   Comparison of NTIMS and ICP-OES methods for the determination of boron concentrations in natural fresh and saline waters [J].
Barth, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (7-8) :854-855
[5]   RAPID AND HIGH-PRECISION DETERMINATION OF BORON ISOTOPE RATIOS IN BORON-CARBIDE BY THERMAL IONIZATION MASS-SPECTROMETRIC MEASUREMENT OF THE DICESIUM METABORATE CATION [J].
BEARY, ES ;
XIAO, YK .
ANALYST, 1990, 115 (07) :911-913
[6]  
Binner J., 2021, STRUCTURAL THERMO ST
[7]   Advances in elemental imaging of rocks using the AGLAE external microbeam [J].
Calligaro, T. ;
Coquinot, Y. ;
Pichon, L. ;
Moignard, B. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (20) :2364-2372
[8]   Development of Particle Induced Gamma-Ray Emission Methods for Nondestructive Determination of Isotopic Composition of Boron and Its Total Concentration in Natural and Enriched Samples [J].
Chhillar, Sumit ;
Acharya, Raghunath ;
Sodaye, Supama ;
Pujari, Pradeep K. .
ANALYTICAL CHEMISTRY, 2014, 86 (22) :11167-11173
[9]   DETERMINATION OF BORON AND LITHIUM IN NUCLEAR-MATERIALS BY SECONDARY ION MASS-SPECTROMETRY [J].
CHRISTIE, WH ;
EBY, RE ;
WARMACK, RJ ;
LANDAU, L .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :13-17
[10]   Development of a Novel Method for Unraveling the Origin of Natron Flux Used in Roman Glass Production Based on B Isotopic Analysis via Multicollector Inductively Coupled Plasma Mass Spectrometry [J].
Devulder, Veerle ;
Degryse, Patrick ;
Vanhaecke, Frank .
ANALYTICAL CHEMISTRY, 2013, 85 (24) :12077-12084