Use of an electrochemical room temperature ionic liquid-based microprobe for measurements in gaseous atmospheres

被引:18
作者
Toniolo, Rosanna [1 ]
Bortolomeazzi, Renzo [1 ]
Svigelj, Rossella [1 ]
Dossi, Nicolo [1 ]
Casella, Innocenzo G. [2 ]
Bragato, Carlo [3 ]
Daniele, Salvatore [3 ]
机构
[1] Univ Udine, Dept Agr Food Environm & Anim Sci, Via Cotonificio 108, I-33100 Udine, Italy
[2] Univ Basilicata, Dept Sci, Viale Ateneo Lucano 10, I-85100 Potenza, Italy
[3] Univ Ca Foscari Venezia, Dept Mol Sci & Nanosyst, Via Torino 155, I-30137 Mestre Venezia, Italy
关键词
Room temperature ionic liquids; Micro-voltammetric cell; Gaseous atmospheres; Oxygen determination; AMPEROMETRIC GAS SENSORS; EXCHANGE MEMBRANES; ELECTROGENERATED SUPEROXIDE; OXYGEN REDUCTION; DISK ELECTRODES; FERROCENE; VOLTAMMETRY; DIFFUSION; MICROELECTRODE; ELECTROLYTES;
D O I
10.1016/j.snb.2016.08.139
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple electrochemical microprobe (EMP) is proposed for the detection of analytes in gaseous atmospheres. The EMP consists of two platinum fibres of 25 and 300 pm in diameter encased into a theta glass pipette to form an electrochemical cell in a two-electrode configuration. Ion conductivity between the two electrodes is ensured by a thin film of the room temperature ionic liquid (RTIL), 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, which is applied onto the EMP tip surface by a simple dip-coating procedure. The ionic liquid-coated microprobe (RTIL-EMP) was preliminarily investigated by using ferrocene as an electroactive species to ascertain the mass transport properties of the analytes that influence the voltammetric responses as well as the stability and reproducibility of the RTIL-EMP in the gas phase. The performance of the RTIL-EMP to gas analysis was afterward evaluated by using oxygen as electroactive species. The RTIL-EMP was exposed to different synthetic O-2/N-2 (v/v) mixtures and current responses were recorded as a function of O-2 concentration, using either cyclic voltammetry (CV) or chronoamperometry (CA). Regression analysis of the experimental current against % O-2 was linear over the range 0-100% with correlation coefficient and sensitivity of, respectively, 0.996 and 0.29 nA/(v/v) % O-2 in CV and 0.998 and 0.27 nA/(v/v) % O-2 in CA measurements. Long term stability, reproducibility of the RTIL-EMP recovery of the RTIL film layers to the initial conditions and effects of humidity on the current responses were investigated in detail. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 247
页数:9
相关论文
共 54 条
  • [1] LINEAR SWEEP VOLTAMMETRY AT VERY SMALL STATIONARY DISK ELECTRODES
    AOKI, K
    AKIMOTO, K
    TOKUDA, K
    MATSUDA, H
    OSTERYOUNG, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 171 (1-2): : 219 - 230
  • [2] Voltammetric behaviour of ferrocene in olive oils mixed with a phosphonium-based ionic liquid
    Baldo, M. Antonietta
    Oliveri, Paolo
    Simonetti, Remo
    Daniele, Salvatore
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 731 : 43 - 48
  • [3] Trace detection of oxygen - ionic liquids in gas sensor design
    Baltes, N.
    Beyle, F.
    Freiner, S.
    Geier, F.
    Joos, M.
    Pinkwart, K.
    Rabenecker, P.
    [J]. TALANTA, 2013, 116 : 474 - 481
  • [4] Extraction of electrode kinetic parameters from microdisc voltammetric data measured under transport conditions intermediate between steady-state convergent and transient linear diffusion as typically applies to room temperature ionic liquids
    Barnes, Alexander S.
    Rogers, Emma I.
    Streeter, Ian
    Aldous, Leigh
    Hardacre, Christopher
    Compton, Richard G.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2008, 112 (25) : 7560 - 7565
  • [5] Electroanalytical sensors for nonconducting media based on electrodes supported on perfluorinated ion-exchange membranes
    Bontempelli, G
    Comisso, N
    Toniolo, R
    Schiavon, G
    [J]. ELECTROANALYSIS, 1997, 9 (06) : 433 - 443
  • [6] Concentration-dependent diffusion in room temperature ionic liquids: a microelectrode study
    Brooks, CA
    Doherty, AP
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (08) : 867 - 871
  • [7] Use of room temperature ionic liquids in gas sensor design
    Buzzeo, MC
    Hardacre, C
    Compton, RG
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4583 - 4588
  • [8] Kinetic analysis of the reaction between electrogenerated superoxide and carbon dioxide in the room temperature ionic liquids 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide and hexyltriethylammonium bis(trifluoromethylsulfonyl)imide
    Buzzeo, MC
    Klymenko, OV
    Wadhawan, JD
    Hardacre, C
    Seddon, KR
    Compton, RG
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (12) : 3947 - 3954
  • [9] Cao Z., 1992, ELECTROANAL, V4, P253, DOI DOI 10.1002/ELAN.1140040302
  • [10] AMPEROMETRIC GAS SENSORS
    CHANG, SC
    STETTER, JR
    CHA, CS
    [J]. TALANTA, 1993, 40 (04) : 461 - 477