Chromatographic fingerprinting analysis of Zhizhu Wan preparation by high-performance liquid chromatography coupled with photodiode array detector

被引:17
作者
Sun, Hui [1 ]
Chen, Xi [1 ]
Zhang, Aihua [1 ]
Sakurai, Tetsuro [1 ]
Jiang, Jinzhong [1 ]
Wang, Xijun [1 ]
机构
[1] Heilongjiang Univ Chinese Med, Dept Pharmaceut Anal, Natl TCM Key Lab Serum Pharmacochem, Key Lab Chinmed, Harbin 150040, Peoples R China
关键词
Chromatographic fingerprinting; high-performance liquid chromatography coupled with photodiode array detector; quality control; traditional Chinese medicine; Zhizhu Wan; QUALITY-CONTROL; CHEMICAL-CONSTITUENTS; ZHU WAN; CHINESE; PHARMACOKINETICS; COMPONENTS; FORMULAS;
D O I
10.4103/0973-1296.141819
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Background: Traditional Chinese medicine (TCM) formula has been used for over 1000 years and most of them contain complicate chemical constituents. Chromatographic fingerprinting has been widely accepted as a crucial method for qualitative and quantitative analyses for TCM. Zhi Zhu Wan (ZZW), a classical Chinese medical formula, has been commonly used for the treatment of gastrointestinal disease, which pose a serious challenge to its quality control. Materials and Methods: In this work, a sensitive and reliable method of high-performance liquid chromatography coupled with photodiode array detector (HPLC-PDA) was developed to control the quality of ZZW for chemical fingerprint analysis and quantitative analysis of four major bioactive constituents, including hesperidin, naringin, neohesperidin, and atractylenolide I. The chromatographic separation was performed on a Waters Symmetry C18 column (4.6 mm x 250 mm, 5 m particle size), with an aqueous 0.095% phosphate acid and acetonitrile mobile phase gradient. Results: Optimization of other experimental conditions was validated with satisfactory accuracy, precision, repeatability, and recovery. In quantitative analysis, the four components showed good regression (R > 0.9994) within test ranges, and the recovery method ranged from 99.32% to 100.630%. HPLC fingerprints of the ZZW samples were compared by performing similarity analysis. Conclusion: The results indicated that the newly developed HPLC-PDA fingerprint method would be suitable for quality control of ZZW.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 18 条
  • [1] Pharmacokinetics-based elucidation on disparity in clinical effectiveness between varieties of Zhi Zhu Wan, a Traditional Chinese Medical formula
    Cao, Hongxin
    Chen, Xi
    Sun, Hui
    Sakurai, Tetsuro
    Zhou, Jue
    Sun, Wenjun
    Lv, Haitao
    Wang, Xijun
    [J]. JOURNAL OF ETHNOPHARMACOLOGY, 2010, 128 (03) : 606 - 610
  • [2] Ultra-performance Liquid Chromatography-High-definition Mass Spectrometry Analysis of Constituents in the Root of Radix Stemonae and those Absorbed in Blood after Oral Administration of the Extract of the Crude Drug
    Dong, Wei
    Wang, Ping
    Meng, Xiangcai
    Sun, Hui
    Zhang, Aihua
    Wang, Weiming
    Dong, Hui
    Wang, Xijun
    [J]. PHYTOCHEMICAL ANALYSIS, 2012, 23 (06) : 657 - 667
  • [3] Ghen Jian-yong, 2004, Zhongguo Zhong Xi Yi Jie He Za Zhi, V24, P25
  • [4] Simultaneous determination of 10 components in traditional Chinese medicine Dachaihu Granule by reversed-phase-high-performance liquid chromatographic-diode array detector
    Hu, Yingfei
    Lu, Tulin
    Mao, Chunqin
    Wu, Hao
    Zhang, Xing
    Wang, J. V.
    Gu, Juanjuan
    [J]. PHARMACOGNOSY MAGAZINE, 2013, 9 (33) : 33 - 38
  • [5] Screening for Compounds with Aromatase Inhibiting Activities from Atractylodes macrocephala Koidz
    Jiang, Hai
    Shi, Jing
    Li, Yuanyuan
    [J]. MOLECULES, 2011, 16 (04) : 3146 - 3151
  • [6] Recent analytical approaches in quality control of traditional Chinese medicines-A review
    Jiang, Yong
    David, Bruno
    Tu, Pengfei
    Barbin, Yves
    [J]. ANALYTICA CHIMICA ACTA, 2010, 657 (01) : 9 - 18
  • [7] Chromatographic fingerprinting and related chemometric techniques for quality control of traditional Chinese medicines
    Liang, Yizeng
    Xie, Peishan
    Chau, Footim
    [J]. JOURNAL OF SEPARATION SCIENCE, 2010, 33 (03) : 410 - 421
  • [8] Simple and Reliable Methods for the Determination of Sixteen Marker Components for Quality Control of Daochi Pill by HPLC Coupled with Diode Array Detection
    Lu, Binan
    Liu, Yuetao
    Yin, Lianhong
    Wang, Xiaona
    Peng, Jinyong
    [J]. PHYTOCHEMICAL ANALYSIS, 2009, 20 (05) : 385 - 394
  • [9] Pharmacokinetics of Hesperetin and Naringenin in the Zhi Zhu Wan, a Traditional Chinese Medicinal Formulae, and its Pharmacodynamics Study
    Sun, Hui
    Dong, Tianwei
    Zhang, Aihua
    Yang, Jinfeng
    Yan, Guangli
    Sakurai, Tetsuro
    Wu, Xiuhong
    Han, Ying
    Wang, Xijun
    [J]. PHYTOTHERAPY RESEARCH, 2013, 27 (09) : 1345 - 1351
  • [10] Rapid discovery and global characterization of chemical constituents and rats metabolites of Phellodendri amurensis cortex by ultra-performance liquid chromatography-electrospray ionization/quadrupole-time-of-flight mass spectrometry coupled with pattern recognition approach
    Wang, Huiyu
    Yan, Guangli
    Zhang, Aihua
    Li, Yuan
    Wang, Yangyang
    Sun, Hui
    Wu, Xiuhong
    Wang, Xijun
    [J]. ANALYST, 2013, 138 (11) : 3303 - 3312