Microfiber coupler based label-free immunosensor

被引:20
作者
Bo, Lin [1 ]
O'Mahony, Christy Charlton [2 ,3 ]
Semenova, Yuliya [1 ]
Gilmartin, Niamh [2 ]
Wang, Pengfei [1 ]
Farrell, Gerald [1 ]
机构
[1] Dublin Inst Technol, Photon Res Ctr, Dublin 8, Ireland
[2] Dublin City Univ, Biomed Diagnost Inst, Dublin 9, Ireland
[3] Dublin City Univ, Sch Phys Sci, Dublin 9, Ireland
关键词
BIOSENSOR;
D O I
10.1364/OE.22.008150
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical microfibers and related structures which incorporate large evanescent field and minimal size offer new opportunities for biosensing applications. In this paper we report the development of an immunosensor based on a tapered microfiber coupler embedded in a low refractive index polymer. Biomolecules adsorbed on the microfiber coupler surface modify the surrounding refractive index. By immobilizing antigens on the surface of the sensing area, the microfiber coupler was able to operate as a label-free immunosensor to detect specific antibodies. We experimentally demonstrated for the first time the sensing ability of this sensor using a fibrinogen antigen-antibody pair. By monitoring the spectral shift in the wavelength domain, the sensor was shown to be capable of detecting the specific binding between fibrinogen and anti-fibrinogen. The detected signal was found to be proportional to the anti-fibrinogen present. (C) 2013 Optical Society of America
引用
收藏
页码:8150 / 8155
页数:6
相关论文
共 20 条
[1]   Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor [J].
Anderson, GP ;
Nerurkar, NL .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 271 (1-2) :17-24
[2]   High Sensitivity Fiber Refractometer Based on an Optical Microfiber Coupler [J].
Bo, Lin ;
Wang, Pengfei ;
Semenova, Yuliya ;
Farrell, Gerald .
IEEE PHOTONICS TECHNOLOGY LETTERS, 2013, 25 (03) :228-230
[3]   Ultra-low-loss optical fiber nanotapers [J].
Brambilla, G ;
Finazzi, V ;
Richardson, DJ .
OPTICS EXPRESS, 2004, 12 (10) :2258-2263
[4]   Tapered optical fiber biosensor for the detection of anti-gliadin antibodies [J].
Corres, J. M. ;
Matias, I. R. ;
Bravo, J. ;
Arregui, F. J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :166-171
[5]   Localized surface plasmon resonance based optical biosensor using surface modified nanoparticle layer for label-free monitoring of antigen-antibody reaction [J].
Endo, T ;
Yamamura, S ;
Nagatani, N ;
Morita, Y ;
Takamura, Y ;
Tamiya, E .
SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2005, 6 (05) :491-500
[6]   Optical microfiber coupler for broadband single-mode operation [J].
Jung, Yongmin ;
Brambilla, Gilberto ;
Richardson, David J. .
OPTICS EXPRESS, 2009, 17 (07) :5273-5278
[7]   POWER TRANSFER IN FUSED BICONICAL-TAPER SINGLE-MODE FIBER COUPLERS - DEPENDENCE ON EXTERNAL REFRACTIVE-INDEX [J].
LAMONT, RG ;
JOHNSON, DC ;
HILL, KO .
APPLIED OPTICS, 1985, 24 (03) :327-332
[8]  
Okamoto K., 2006, Fundamentals of Optical Waveguides, V2nd
[9]   POLARIZATION ANALYSIS OF STRONGLY FUSED AND WEAKLY FUSED TAPERED COUPLERS [J].
PAYNE, FP ;
HUSSEY, CD ;
YATAKI, MS .
ELECTRONICS LETTERS, 1985, 21 (13) :561-563
[10]   Experimental study of temperature response of a microfiber coupler sensor with a liquid crystal overlay [J].
Semenova, Yuliya ;
Bo, Lin ;
Wang, Pengfei ;
Mathews, Sunish ;
Wu, Qiang ;
Teng, Mianzhen ;
Yu, Chongxiu ;
Farrell, Gerald .
FIFTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2013, 8794