Infrared imaging spectroscopy and chemometric tools for in situ analysis of an imiquimod pharmaceutical preparation presented as cream

被引:22
作者
Carneiro, Renato Lajarim [1 ]
Poppi, Ronei Jesus [1 ]
机构
[1] Univ Campinas UNICAMP, Inst Chem, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Imiquimod; Multivariate curve resolution; Principal component analysis; Infrared imaging spectroscopy; Pharmaceutical formulations analysis; SOLID DOSAGE FORMS; FEASIBILITY; SAMPLES;
D O I
10.1016/j.saa.2013.08.104
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In the present work the homogeneity of a pharmaceutical formulation presented as a cream was studied using infrared imaging spectroscopy and chemometric methodologies such as principal component analysis (PCA) and multivariate curve resolution with alternating least squares (MCR-ALS). A cream formulation, presented as an emulsion, was prepared using imiquimod as the active pharmaceutical ingredient (API) and the excipients: water, vaseline, an emulsifier and a carboxylic acid in order to dissolve the API. After exposure at 45 degrees C during 3 months to perform accelerated stability test, the presence of some crystals was observed, indicating homogeneity problems in the formulation. PCA exploratory analysis showed that the crystal composition was different from the composition of the emulsion, since the score maps presented crystal structures in the emulsion. MCR-ALS estimated the spectra of the crystals and the emulsion. The crystals presented amine and C-H bands, suggesting that the precipitate was a salt formed by carboxylic acid and imiquimod. These results indicate the potential of infrared imaging spectroscopy in conjunction with chemometric methodologies as an analytical tool to ensure the quality of cream formulations in the pharmaceutical industry. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 23 条
[1]   Practical issues of hyperspectral imaging analysis of solid dosage forms [J].
Amigo, Jose Manuel .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (01) :93-109
[2]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[3]   Applications of attenuated total reflection infrared spectroscopic imaging to pharmaceutical formulations [J].
Chan, KLA ;
Hammond, SV ;
Kazarian, SG .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2140-2146
[4]  
Chollet J.L., 1998, 1998 AAPS ANN M SAN
[5]   Extracting process-related information from pharmaceutical dosage forms using near infrared microscopy [J].
Clarke, F .
VIBRATIONAL SPECTROSCOPY, 2004, 34 (01) :25-35
[6]   Spectroscopic imaging and chemometrics: a powerful combination for global and local sample analysis [J].
de Juan, A ;
Tauler, R ;
Dyson, R ;
Marcolli, C ;
Rault, M ;
Maeder, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (01) :70-79
[7]  
FDA, 1997, NONST SEM DOS FORMS, VCMC 7, P19
[8]   Pharmaceutical applications of vibrational chemical imaging and chemometrics: A review [J].
Gendrin, C. ;
Roggo, Y. ;
Collet, C. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) :533-553
[9]   Content uniformity of pharmaceutical solid dosage forms by near infrared hyperspectral imaging: A feasibility study [J].
Gendrin, Christelle ;
Roggo, Yves ;
Collet, Christophe .
TALANTA, 2007, 73 (04) :733-741
[10]   Multi-way methods in image analysis-relationships and applications [J].
Huang, J ;
Wium, H ;
Qvist, KB ;
Esbensen, KH .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 66 (02) :141-158