1-Ethyl-3-Methylimidazolium Ethylsulfate/Copper Catalyst for the Enhancement of Glucose Chemiluminescent Detection: Effects on Light Emission and Enzyme Activity

被引:32
作者
Santafe, Aurelie A. -M. [1 ]
Doumeche, Bastien [1 ]
Blum, Loic J. [1 ]
Girard-Egrot, Agnes P. [1 ]
Marquette, Christophe A. [1 ]
机构
[1] Univ Lyon 1, CNRS ICBMS 5246, Lab Genie Enzymat Membranes Biomimet & Assemblage, Inst Chim & Biochim Mol & Supramol, F-69622 Villeurbanne, France
关键词
FLOW-INJECTION ANALYSIS; IONIC LIQUIDS; HORSERADISH-PEROXIDASE; HYDROGEN-PEROXIDE; LUMINOL CHEMILUMINESCENCE; CAPILLARY-ELECTROPHORESIS; MECHANISM; ELECTROCHEMILUMINESCENCE; BIOSENSOR;
D O I
10.1021/ac9026725
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of the ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate ([Emim][EtSO4]) on the copper-catalyzed luminol chemiluminescence (CL) is reported. A drastic light emission enhancement is observed, related to a strong interaction between Cu2+ and the imidazolium ring. In these conditions, the CL reaction was able to produce light efficiently at pH as low as 6.5 (amplification factor: Intensity(+IL)/Intensity(-IL) = 2900). Interesting effects of [Emim][EtSO4]) on the enzyme glucose oxidase activity were also evidenced, and advantages were taken from this enhancement to perform sensitive chemiluminescent glucose detection (LOD = 4 mu M) at PH 8.0.
引用
收藏
页码:2401 / 2404
页数:4
相关论文
共 33 条
[1]  
Alici B, 2007, TURK J CHEM, V31, P569
[2]   Formation and stability of N-heterocyclic carbenes in water:: The carbon acid pKa of imidazollum cations in aqueous solution [J].
Amyes, TL ;
Diver, ST ;
Richard, JP ;
Rivas, FM ;
Toth, K .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (13) :4366-4374
[3]   Effect of eluent composition and pH and chemiluminescent reagent pH on ion chromatographic selectivity and luminol-based chemiluminescence detection of Co2+, Mn2+ and Fe2+ at trace levels [J].
Badocco, Denis ;
Pastore, Paolo ;
Favaro, Gabriella ;
Macca, Carlo .
TALANTA, 2007, 72 (01) :249-255
[4]   CHEMILUMINESCENT FLOW-INJECTION ANALYSIS OF GLUCOSE IN DRINKS WITH A BIENZYME FIBEROPTIC BIOSENSOR [J].
BLUM, LJ .
ENZYME AND MICROBIAL TECHNOLOGY, 1993, 15 (05) :407-411
[5]  
BLUM LJ, 1997, BIOCHEMI LUMINESCENT
[6]   MECHANISM OF COBALT CATALYSIS OF LUMINOL CHEMILUMINESCENCE [J].
BURDO, TG ;
SEITZ, WR .
ANALYTICAL CHEMISTRY, 1975, 47 (09) :1639-1643
[7]   Chemiluminescence flow biosensor for hydrogen peroxide using DNAzyme immobilized on eggshell membrane as a thermally stable biocatalyst [J].
Chen, Weiwei ;
Li, Baoxin ;
Xu, Chunli ;
Wang, Lei .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) :2534-2540
[8]   Reactivity of ionic liquids [J].
Chowdhury, Shahana ;
Mohan, Ram S. ;
Scott, Janet L. .
TETRAHEDRON, 2007, 63 (11) :2363-2389
[9]   Mononuclear rearrangement of heterocycles in ionic liquids catalyzed by copper(II) salts [J].
D'Anna, Francesca ;
Frennaa, Vincenzo ;
Marulloa, Salvatore ;
Noto, Renato ;
Spinelli, Domenico .
TETRAHEDRON, 2008, 64 (49) :11209-11217
[10]   Chemiluminescence as a diagnostic tool. A review [J].
Dodeigne, C ;
Thunus, L ;
Lejeune, R .
TALANTA, 2000, 51 (03) :415-439