Lock-in amplifier error prediction and correction in frequency sweep measurements

被引:8
|
作者
Sonnaillona, Maximiliano Osvaldo [1 ]
Bonetto, Fabian Jose [1 ]
机构
[1] Lab Cavitac & Biotecnol, RA-8400 San Carlos De Bariloche, Rio Negro, Argentina
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2007年 / 78卷 / 01期
关键词
D O I
10.1063/1.2428269
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article proposes an analytical algorithm for predicting errors in lock-in amplifiers (LIAs) working with time-varying reference frequency. Furthermore, a simple method for correcting such errors is presented. The reference frequency can be swept in order to measure the frequency response of a system within a given spectrum. The continuous variation of the reference frequency produces a measurement error that depends on three factors: the sweep speed, the LIA low-pass filters, and the frequency response of the measured system. The proposed error prediction algorithm is based on the final value theorem of the Laplace transform. The correction method uses a double-sweep measurement. A mathematical analysis is presented and validated with computational simulations and experimental measurements. (c) 2007 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Low Cost Autonomous Lock-In Amplifier for Resistance/Capacitance Sensor Measurements
    Maya, Paulina
    Calvo, Belen
    Teresa Sanz-Pascual, Maria
    Osorio, Javier
    ELECTRONICS, 2019, 8 (12)
  • [32] Amplitude noise spectrum of a lock-in amplifier: Application to microcantilever noise measurements
    Ruppert, Michael G.
    Bartlett, Nathan J.
    Yong, Yuen K.
    Fleming, Andrew J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 312
  • [33] SELECTION OF DWELL TIME WHEN USING A LOCK-IN AMPLIFIER IN A SEQUENCE OF MEASUREMENTS
    DIJULIO, SS
    KNUTH, EL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (07): : 1154 - 1156
  • [34] High-frequency digital lock-in amplifier using random sampling
    Sormaillon, Maximiliano O.
    Urteaga, Raul
    Bonetto, Fabian J.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (03) : 616 - 621
  • [35] Lock-in amplifier techniques for low-frequency modulated sensor applications
    de Graaf, G.
    Wolffenbuttel, R. F.
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1745 - 1749
  • [36] Analysis and compensation of the measurement error in a lock-in amplifier used for wavelength shift measurement
    Shi, WJ
    Ning, YN
    Grattan, KTV
    Palmer, AW
    Huang, SL
    FIBER OPTIC SENSORS V, 1996, 2895 : 258 - 266
  • [37] Digital Lock-in Amplifier Based on Microcontroller
    陶安利
    徐国栋
    骆科学
    张钢领
    Journal of Measurement Science and Instrumentation, 2010, 1 (03) : 285 - 288
  • [38] Lock-in amplifier with autotracking bandpass filter
    Sato, A
    Ohara, A
    Ogawa, Y
    Suzuki, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (11): : 4021 - 4022
  • [39] FPGA based Adaptive Lock-in Amplifier
    Aparna, A., V
    Sukumar, N.
    Sumathi, P.
    2022 IEEE 19TH INDIA COUNCIL INTERNATIONAL CONFERENCE, INDICON, 2022,
  • [40] Low cost Lock-in Amplifier Solutions
    Belea, Radu
    Epure, Silviu
    2017 IEEE 23RD INTERNATIONAL SYMPOSIUM FOR DESIGN AND TECHNOLOGY IN ELECTRONIC PACKAGING (SIITME), 2017, : 118 - 121