Effect of non-sinusoidal excitation to inrush current for transformer

被引:0
作者
Cheng, C. L. [1 ]
Chern, S. C. [1 ]
Yeh, J. C. [1 ]
Huang, Y. T. [1 ]
机构
[1] Natl Formosa Univ, Dept Elect Engn, Yunlin 632, Taiwan
来源
2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3 | 2006年
关键词
transient analysis; transformers; harmonics;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inrush current is an important issue for transformers security and stability. Harmonic effects in power systems have been significantly increasing in the last decade. In this paper, SINm(omega t) waveforms represent non-sinusoidal waveforms because studies on SINm(cot) waveforms appear to be simpler for more predictable results. A flux analysis of single-phase transformer is proposed in this paper. Furthermore, an active suppression method of inrush current is proposed. Finally, the effect of non-sinusoidal excitation to inrush current is analyzed and discussed in detail.
引用
收藏
页码:1454 / +
页数:2
相关论文
共 50 条
[41]   A Method for Calculation of the Inrush Current in Single Phase Transformer including the Residual Flux [J].
Waindok, Andrzej .
PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (5B) :194-201
[42]   On-line analysis of power quality problems in non-sinusoidal/non-linear distribution systems [J].
El-Goharey, Hamdy S. K. ;
Mamdouh, Wael M. .
AIN SHAMS ENGINEERING JOURNAL, 2023, 14 (09)
[43]   Selection of suitable fuzzy operators for representative power factor evaluation in non-sinusoidal situations [J].
Morsi, W. G. ;
El-Hawary, M. E. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) :1381-1387
[44]   Resonance Excited by Transformer Inrush Current in Inter-connected Offshore Power Systems [J].
Turner, R. A. ;
Smith, K. S. .
2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, :1777-1783
[45]   Transformer Protection by Distinguishing Inrush and Fault Current with Harmonic Analysis Using Fuzzy Logic [J].
Deshmukh, Madhura S. ;
Barhate, V. T. .
PROCEEDINGS OF 2016 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND ROBOTICS ENGINEERING, 2016, :109-113
[46]   Extraction Of Features To Discriminate And Detect Transformer Inrush Current And Faulty Condition Using ANN [J].
Moon, Reena R. ;
Dhatrak, R. K. .
2014 ANNUAL INTERNATIONAL CONFERENCE ON EMERGING RESEARCH AREAS: MAGNETICS, MACHINES AND DRIVES (AICERA/ICMMD), 2014,
[47]   Transformer Inrush Current Mitigation Techniques for Grid-Forming Inverters Dominated Grids [J].
Alassi, Abdulrahman ;
Ahmed, Khaled H. ;
Egea-Alvarez, Agusti ;
Foote, Colin .
IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (03) :1610-1620
[48]   Active Energy Meters Tested in Realistic Non-Sinusoidal Conditions Recorded on the Field and Reproduced in Laboratory [J].
Cultrera, Alessandro ;
Germito, Gabriele ;
Serazio, Danilo ;
Galliana, Flavio ;
Trinchera, Bruno ;
Aprile, Giulia ;
Chirulli, Martino ;
Callegaro, Luca .
ENERGIES, 2024, 17 (06)
[49]   Design and Implementation of a High Accuracy Sampling Wattmeter under Non-sinusoidal and Time Varying Environments [J].
Sarkar, Arghya ;
Sengupta, S. .
2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, :1237-+
[50]   Optimal Passive Filter Design for Effective Utilization of Cables and Transformers under Non-sinusoidal Conditions [J].
Aleem, Shady H. E. Abdel ;
Balci, Murat E. ;
Zobaa, Ahmed F. ;
Sakar, Selcuk .
2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, :626-630