Parameterization of red blood cell elongation index - shear stress curves obtained by ektacytometry

被引:125
作者
Baskurt, Oguz K. [1 ]
Hardeman, Max R. [2 ]
Uyuklu, Mehmet [1 ]
Ulker, Pinar [1 ]
Cengiz, Melike [1 ]
Nemeth, Norbert [3 ]
Shin, Sehyun [4 ]
Alexy, Tamas [5 ]
Meiselman, Herbert J. [5 ]
机构
[1] Akdeniz Univ, Dept Physiol, Fac Med, TR-07058 Antalya, Turkey
[2] Univ Amsterdam, Acad Med Ctr, Dept Physiol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Debrecen, Med & Hlth Sci Ctr, Inst Surg, Dept Operat Tech & Surg Res, Debrecen, Hungary
[4] Korea Univ, Dept Mech Engn, Seoul, South Korea
[5] Univ So Calif, Keck Sch Med, Dept Physiol & Biophys, Los Angeles, CA 90033 USA
关键词
Hemorheology; erythrocyte deformability; ektacytometry; glutaraldehyde; Lineweaver-Burke; ERYTHROCYTE DEFORMABILITY; INSTRUMENT; RHEOLOGY;
D O I
10.3109/00365510903266069
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Measurement of red blood cell (RBC) deformability by ektacytometry yields a set of elongation indexes (EI) measured at various shear stresses (SS) presented as SS-EI curves, or tabulated data. These are useful for detailed analysis, but may not be appropriate when a simple comparison of a global parameter between groups is required. Based on the characteristic shape of SS-EI curves, two approaches have been proposed to calculate the maximal RBC elongation index (EImax) and the shear stress required for one-half of this maximal deformation (SS1/2): (i) linear Lineweaver-Burke (LB) model; (ii) Streekstra-Bronkhorst (SB) model. Both approaches have specific assumptions and thus may be subject to the measurement conditions. Using RBC treated with various concentrations of glutaraldehyde (GA) and data obtained by ektacytometry, the two approaches have been compared for nine different ranges of SS between 0.6-75 Pa. Our results indicate that: (i) the sensitivity of both models can be affected by the SS range and limits employed; (ii) over the entire range of SS-data, a non-linear curve fitting approach to the LB model gave more consistent results than a linear approach; (iii) the LB method is better for detecting SS1/2 differences between RBC treated with 0.001-0.005% glutaraldehyde (GA) and for a 40% mixture of rigid cells but is equally sensitive to SB for 10% rigid cells; and (iv) the LB and SB methods for EImax are equivalent for 0.001% and 0.003% GA and 40% rigid, with the SB better for 0.005% GA and the LB better for 10% rigid.
引用
收藏
页码:777 / 788
页数:12
相关论文
共 19 条
[1]  
Baskurt OK, 2007, BIOMED HEALTH RES, V69, P170
[2]   Comparison of three commercially available ektacytometers with different shearing geometries [J].
Baskurt, Oguz K. ;
Hardeman, M. R. ;
Uyuklu, Mehmet ;
Ulker, Pinar ;
Cengiz, Melike ;
Nemeth, Norbert ;
Shin, Sehyun ;
Alexy, Tamas ;
Meiselman, Herbert J. .
BIORHEOLOGY, 2009, 46 (03) :251-264
[3]   New guidelines for hemorheological laboratory techniques [J].
Baskurt, Oguz K. ;
Boynard, Michel ;
Cokelet, Giles C. ;
Connes, Philippe ;
Cooke, Brian M. ;
Forconi, Sandro ;
Liao, Fulong ;
Hardeman, Max R. ;
Jung, Friedrich ;
Meiselman, Herbert J. ;
Nash, Gerard ;
Nemeth, Norbert ;
Neu, Bjoern ;
Sandhagen, Bo ;
Shin, Sehyun ;
Thurston, George ;
Wautier, Jean Luc .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 42 (02) :75-97
[4]  
Baskurt OK, 1996, CLIN HEMORHEOL, V16, P753
[5]  
Baskurt OK, 2004, CLIN HEMORHEOL MICRO, V31, P23
[6]  
Bronkhorst PJH, 1995, CLIN HEMORHEOL, V15, P803
[7]   RED-CELL DEFORMABILITY AND ITS RELEVANCE TO BLOOD-FLOW [J].
CHIEN, S .
ANNUAL REVIEW OF PHYSIOLOGY, 1987, 49 :177-192
[8]  
Cohen J., 1998, Statistical power analysis for the behavioral sciences, V4
[9]   Appearance of an erythrocyte population with decreased deformability and hemoglobin content following sepsis [J].
Condon, MR ;
Kim, JE ;
Deitch, EA ;
Machiedo, GW ;
Spolarics, Z .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 284 (06) :H2177-H2184
[10]  
Cooke BM, 2007, BIOMED HEALTH RES, V69, P91