Transcranial Ultrasonic Therapy Based on Time Reversal of Acoustically Induced Cavitation Bubble Signature

被引:71
作者
Gatcau, Jerome [1 ]
Marsac, Laurent [2 ]
Pernot, Mathieu
Aubry, Jean-Francois
Tanter, Mickael
Fink, Mathias
机构
[1] Univ Paris 07, Ecole Super Phys & Chim Ind Ville Paris, Langevin Inst, Inserm,Wave Phys Med U979,CNRS,UMR 7587, Paris, France
[2] Superson Imagine, F-13857 Aix En Provence, France
关键词
Acoustic beam steering; acoustic cavitation; adaptive arrays; transcranial brain therapy; PHASE-ABERRATION CORRECTION; AGAR BASED GELS; DIFFUSE; TISSUE; SKULL;
D O I
10.1109/TBME.2009.2031816
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Brain treatment through the skull with high-intensity focused ultrasound can be achieved with multichannel arrays and adaptive focusing techniques such as time reversal. This method requires a reference signal to be either emitted by a real source embedded in brain tissues or computed from a virtual source, using the acoustic properties of the skull derived from computed tomography images. This noninvasive computational method focuses with precision, but suffers from modeling and repositioning errors that reduce the accessible acoustic pressure at the focus in comparison with fully experimental time reversal using an implanted hydrophone. In this paper, this simulation-based targeting has been used experimentally as a first step for focusing through an ex vivo human skull at a single location. It has enabled the creation of a cavitation bubble at focus that spontaneously emitted an ultrasonic wave received by the array. This active source signal has allowed 97 +/- 1.1% of the reference pressure (hydrophone-based) to be restored at the geometrical focus. To target points around the focus with an optimal pressure level, conventional electronic steering from the initial focus has been combined with bubble generation. Thanks to step-by-step bubble generation, the electronic steering capabilities of the array through the skull were improved.
引用
收藏
页码:134 / 144
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 1998, ULTRASOUND MED BIOL, V24, pS11
[2]   Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans [J].
Aubry, JF ;
Tanter, M ;
Pernot, M ;
Thomas, JL ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :84-93
[3]  
Blatteau JE, 2006, AVIAT SPACE ENVIR MD, V77, P1068
[4]   Frequency, pulse length, and the mechanical index [J].
Church, CC .
ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2005, 6 (03) :162-168
[5]   Spontaneous homogeneous nucleation, inertial cavitation and the safety of diagnostic ultrasound [J].
Church, CC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (10) :1349-1364
[6]   ULTRASONICALLY INDUCED GAS BUBBLE PRODUCTION IN AGAR BASED GELS .2. THEORETICAL-ANALYSIS [J].
CRUM, LA ;
DANIELS, S ;
TERHAAR, GR ;
DYSON, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (09) :541-554
[7]   ULTRASONICALLY INDUCED GAS BUBBLE PRODUCTION IN AGAR BASED GELS .1. EXPERIMENTAL INVESTIGATION [J].
DANIELS, S ;
BLONDEL, D ;
CRUM, LA ;
TERHAAR, GR ;
DYSON, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (09) :527-539
[8]   TIME-REVERSAL OF ULTRASONIC FIELDS .1. BASIC PRINCIPLES [J].
FINK, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (05) :555-566
[9]   Time-reversal acoustics in biomedical engineering [J].
Fink, M ;
Montaldo, G ;
Tanter, M .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2003, 5 :465-497
[10]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES [J].
FLAX, SW ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :758-767