Comparison of ultraviolet detection, evaporative light scattering detection and charged aerosol detection methods for liquid-chromatographic determination of anti-diabetic drugs

被引:57
作者
Shaodong, Jia [1 ,2 ]
Lee, Won Jun [1 ,2 ]
Ee, Ji Won [1 ,2 ]
Park, Jeong Hill [1 ,2 ]
Kwon, Sung Won [1 ,2 ]
Lee, Jeongmi [3 ]
机构
[1] Seoul Natl Univ, Coll Pharm, Seoul 151742, South Korea
[2] Seoul Natl Univ, Res Inst Pharmaceut Sci, Seoul 151742, South Korea
[3] Sungkyunkwan Univ, Coll Pharm, Suwon 440746, South Korea
关键词
Glipizide; Gliclazide; Glibenclamide; Glimepiride; HPLC; ELSD; CAD; Pharmaceutical analysis; SUPERCRITICAL-FLUID CHROMATOGRAPHY; HUMAN-PLASMA; UNIVERSAL RESPONSE; HPLC; GLIBENCLAMIDE; URINE; COMPENSATION; GLIPIZIDE; METFORMIN;
D O I
10.1016/j.jpba.2009.10.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, charged aerosol detection (CAD), a new kind of universal detection method, has been widely employed in the HPLC system. In the present study, four kinds of anti-diabetic drug standards, glipizide, gliclazide, glibenclamide and glimepiride were determined by ultraviolet (UV) detection, evaporative light scattering detection (ELSD) and the aforementioned CAD. The results were compared with reference to linearity, accuracy, precision and limit of detection (LOD). All of the experiments were performed on a reverse phase column with water and acetonitrile as the mobile phase. Separations were achieved under the same chromatographic conditions for each detection method. As a result, CAD generated nearly uniform responses compared with UV detection and ELSD. It showed the best accuracy and LOD among 3 detectors and had similar precision with UV detection at higher concentrations while UV detection showed a better precision at lower concentrations than did CAD or ELSD. The LOD of CAD, in fact, can be up to two times higher than that of ELSD. The UV and ELSD linearity was satisfactory at R-2 > 0.99, though in the case of CAD, a log-log transformation was needed. The proposed methods were also applied to the real anti-diabetic drugs and diabetes-related dietary supplements. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:973 / 978
页数:6
相关论文
共 30 条
[1]   The development and validation of liquid chromatography method for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma [J].
AbuRuz, S ;
Millership, J ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02) :277-286
[2]   Corona-charged aerosol detection in supercritical fluid chromatography for pharmaceutical analysis [J].
Brunelli, C. ;
Gorecki, T. ;
Zhao, Y. ;
Sandra, P. .
ANALYTICAL CHEMISTRY, 2007, 79 (06) :2472-2482
[3]   Development of analytical procedures to study changes in the composition of meat phospholipids caused by induced oxidation [J].
Cascone, Annunziata ;
Eerola, Susanna ;
Ritieni, Alberto ;
Rizzo, Aldo .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) :211-220
[4]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[5]   Improving the universal response of evaporative light scattering detection by mobile phase compensation [J].
de Villiers, Andre ;
Gorecki, Tadeusz ;
Lynen, Frederic ;
Szucs, Roman ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) :183-191
[6]   Quantification of pegylated phospholipids decorating polymeric microcapsules of perfluorooctyl bromide by reverse phase HPLC with a charged aerosol detector [J].
Diaz-Lopez, R. ;
Libong, D. ;
Tsapis, N. ;
Fattal, E. ;
Chaminade, P. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) :702-707
[7]   Development and testing of a detection method for liquid chromatography based on aerosol charging [J].
Dixon, RW ;
Peterson, DS .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :2930-2937
[8]  
El-Enany N., 2004, Farmaco (Lausanne), V59, P63, DOI 10.1016/j.farmac.2003.08.007
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF GLIPIZIDE IN HUMAN-PLASMA AND URINE [J].
EMILSSON, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (02) :319-326
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF GLIBENCLAMIDE IN HUMAN-PLASMA AND URINE [J].
EMILSSON, H ;
SJOBERG, S ;
SVEDNER, M ;
CHRISTENSON, I .
JOURNAL OF CHROMATOGRAPHY, 1986, 383 (01) :93-102