Factors Influencing Poor Outcomes in Synthetic Tissue-Engineered Tracheal Replacement

被引:26
|
作者
Pepper, Victoria [1 ]
Best, Cameron A. [2 ,3 ]
Buckley, Kaila [4 ]
Schwartz, Cynthia [5 ]
Onwuka, Ekene [6 ]
King, Nakesha [6 ]
White, Audrey [7 ]
Dharmadhikari, Sayali [2 ,8 ]
Reynolds, Susan D. [9 ]
Johnson, Jed [10 ]
Grischkan, Jonathan [8 ]
Breuer, Christopher K. [2 ,11 ]
Chiang, Tendy [2 ,8 ]
机构
[1] Loma Linda Childrens Hosp, Div Pediat Surg, Loma Linda, CA USA
[2] Nationwide Childrens Hosp, Res Inst, Ctr Regenerat Med, Columbus, OH USA
[3] Ohio State Univ, Coll Med, Biomed Sci Grad Program, Columbus, OH 43210 USA
[4] Ohio State Univ, Dept Pathol, Columbus, OH 43210 USA
[5] Texas Tech Univ, Hlth Sci Ctr, Dept Otolaryngol, Lubbock, TX 79430 USA
[6] Ohio State Univ, Dept Gen Surg, Columbus, OH 43210 USA
[7] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
[8] Nationwide Childrens Hosp, Dept Otolaryngol Head & Neck Surg, Columbus, OH USA
[9] Nationwide Childrens Hosp, Res Inst, Ctr Perinatal Res, Columbus, OH USA
[10] Nanofiber Solut Inc, Hilliard, OH USA
[11] Nationwide Childrens Hosp, Dept Pediat Surg, Columbus, OH USA
关键词
tissue engineering; trachea; regenerative medicine; biomaterials; stem cells; MARROW MONONUCLEAR-CELLS; 4-YEAR FOLLOW-UP; VASCULAR GRAFTS; COMPLIANCE MISMATCH; TRANSPLANTATION; STENOSIS; CHILD; SCAFFOLD; SYSTEM;
D O I
10.1177/0194599819844754
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives Humans receiving tissue-engineered tracheal grafts have experienced poor outcomes ultimately resulting in death or the need for graft explantation. We assessed the performance of the synthetic scaffolds used in humans with an ovine model of orthotopic tracheal replacement, applying standard postsurgical surveillance and interventions to define the factors that contributed to the complications seen at the bedside. Study Design Large animal model. Setting Pediatric academic research institute. Subjects and Methods Human scaffolds were manufactured with an electrospun blend of polyethylene terephthalate and polyurethane reinforced with polycarbonate rings. They were seeded with autologous bone marrow-derived mononuclear cells and implanted in sheep. Animals were evaluated with routine bronchoscopy and fluoroscopy. Endoscopic dilation and stenting were performed to manage graft stenosis for up to a 4-month time point. Grafts and adjacent native airway were sectioned and evaluated with histology and immunohistochemistry. Results All animals had signs of graft stenosis. Three of 5 animals (60%) designated for long-term surveillance survived until the 4-month time point. Graft dilation and stent placement resolved respiratory symptoms and prolonged survival. Necropsy demonstrated evidence of infection and graft encapsulation. Granulation tissue with signs of neovascularization was seen at the anastomoses, but epithelialization was never observed. Acute and chronic inflammation of the native airway epithelium was observed at all time points. Architectural changes of the scaffold included posterior wall infolding and scaffold delamination. Conclusions In our ovine model, clinically applied synthetic tissue-engineered tracheas demonstrated infectious, inflammatory, and mechanical failures with a lack of epithelialization and neovascularization.
引用
收藏
页码:458 / 467
页数:10
相关论文
共 50 条
  • [21] Human-iliac vein replacement with a tissue-engineered graft
    Teebken, O. E.
    Puschmann, C.
    Rohde, B.
    Burgwitz, K.
    Winkler, M.
    Pichlmaier, A. M.
    Weidemann, J.
    Haverich, A.
    VASA-JOURNAL OF VASCULAR DISEASES, 2009, 38 (01): : 60 - 65
  • [22] A tissue-engineered rostral migratory stream for directed neuronal replacement
    O'Donnell, John C.
    Katiyar, Kritika S.
    Panzer, Kate V.
    Cullen, D. Kacy
    NEURAL REGENERATION RESEARCH, 2018, 13 (08) : 1327 - 1331
  • [23] Progress in the development of a corneal replacement: keratoprostheses and tissue-engineered corneas
    Duan, Derek
    Klenkler, Bettina J.
    Sheardown, Heather
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (01) : 59 - 72
  • [24] A tissue-engineered rostral migratory stream for directed neuronal replacement
    John C.O'Donnell
    Kritika S.Katiyar
    Kate V.Panzer
    D.Kacy Cullen
    NeuralRegenerationResearch, 2018, 13 (08) : 1327 - 1331
  • [25] Replacement of renal function in uremic animals with a tissue-engineered kidney
    Humes, HD
    Buffington, DA
    MacKay, SM
    Funke, AJ
    Weitzel, WF
    NATURE BIOTECHNOLOGY, 1999, 17 (05) : 451 - 455
  • [26] Autologous Implantation of Bilayered Tissue-Engineered Respiratory Epithelium for Tracheal Mucosal Regenesis in a Sheep Model
    Heikal, M. Y. Mohd
    Aminuddin, B. S.
    Jeevanan, J.
    Chen, H. C.
    Sharifah, S. H.
    Ruszymah, B. H. I.
    CELLS TISSUES ORGANS, 2010, 192 (05) : 292 - 302
  • [27] Tissue-engineered buccal mucosa urethroplasty - Clinical outcomes
    Bhargava, Saurabh
    Patterson, Jacob M.
    Inman, Richard D.
    MacNeil, Sheila
    Chapple, Christopher R.
    EUROPEAN UROLOGY, 2008, 53 (06) : 1263 - 1271
  • [28] Replacement of a 5-cm Intrathoracic Trachea With a Tissue-Engineered Prosthesis in a Canine Model
    Ueda, Yuichiro
    Sato, Toshihiko
    Yutaka, Yojiro
    Nakamura, Tatsuo
    Tanaka, Seiichi
    Iwasaki, Akinori
    Date, Hiroshi
    ANNALS OF THORACIC SURGERY, 2022, 113 (06) : 1891 - 1900
  • [29] Tissue-engineered tracheal reconstruction using chondrocyte seeded on a porcine cartilage-derived substance scaffold
    Shin, Yoo Seob
    Lee, Bum Hee
    Choi, Jae Won
    Min, Byoung-Hyun
    Chang, Jae Won
    Yang, Soon Sim
    Kim, Chul-Ho
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2014, 78 (01) : 32 - 38
  • [30] Long-term functional reconstruction of segmental tracheal defect by pedicled tissue-engineered trachea in rabbits
    Luo, Xusong
    Liu, Yi
    Zhang, Zhiyong
    Tao, Ran
    Liu, Yu
    He, Aijuan
    Yin, Zongqi
    Li, Dan
    Zhang, Wenjie
    Liu, Wei
    Cao, Yilin
    Zhou, Guangdong