Determination of 11 Phthalate Esters in Beverages by Magnetic Solid-Phase Extraction Combined with High-Performance Liquid Chromatography

被引:0
|
作者
Yin, Shuo [1 ]
Yang, Yi [1 ]
Yang, Danni [1 ]
Li, Yongxin [1 ,2 ]
Jiang, Yang [3 ]
Wu, Ling [1 ]
Sun, Chengjun [1 ,2 ]
机构
[1] Sichuan Univ, West China Sch Publ Hlth, Chengdu 610041, Sichuan, Peoples R China
[2] Prov Key Lab Food Safety Monitoring & Risk Assess, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Prov Ctr Dis Control & Prevent, Chengdu 610041, Sichuan, Peoples R China
关键词
ENVIRONMENTAL WATER; BOTTLED WATER; ACID-ESTERS; NANOPARTICLES; SAMPLES; MICROEXTRACTION; ADSORBENTS;
D O I
10.1093/jaoac/102.5.1624
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Beverages can be easily contaminated by phthalate esters (PAEs) during the production, bottling, and transportation processes. It is necessary to determine the contamination level in beverages for assessment of human exposure. Objective: In this study, magnetic solid-phase extraction (MSPE) was combined with HPLC for the determination of 11 PAEs in beverages. Methods: Self-synthesized magnetic multiwalled carbon nanotubes (m-MWCNTs) were used as the adsorbent for PAE extraction. To extract the PAEs, an appropriate amount of m-MWCNTs and NaCl was added to the beverage sample. The mixture was mixed on a vortex mixer, the magnetic sorbent was collected with the aid of a magnet, and the supernatant was removed. Then, the analytes were eluted with n-hexane acetone (1+1, v/v). Finally, the eluent was analyzed by the HPLC method. The separation was accomplished on a Phenomenex Luna-C18 column (250 x 4.6 mm, 5 mu m), and the detection wavelength was set at 225 nm. Results: The linear ranges of the method were 2-300 mu g/L with correlation coefficients greater than 0.9981. The LOD and LOQ were in the range of 0.659-5.33 x 10(-2) mu g/L and 2.20-17.8 x 10(-2) mu g/L, respectively. The recoveries of the method ranged from 79.8 to 114%, with the relative SDs less than 15.8%. The established method has been successfully applied for the determination of 11 PAEs in mineral water, carbonated soft drink, tea beverage, and fruit juice samples. PAEs were detected at 0.246-34.3 mu g/L in these samples. Conclusions: The m-MWCNTs are the satisfactory sorbent for MSPE because of their strong adsorption capacity for PAEs. The established MSPE-HPLC method is rapid, easy, sensitive, green, and cost-effective. It can be applied to the analysis of trace PAEs in plastic bottled beverages. Highlights: Three magnetic nanoparticles (MNPs), including Fe3O4 MNPs, m-MWCNTs, and magnetic graphene oxide, were synthesized, and m-MWCNTs were chosen as the sorbent of MSPE for PAE extraction because of their strong adsorption capacity for PAEs. An MSPE HPLC method has been developed for the analysis of 11 phthalates in plastic bottled beverages. The established method was successfully applied to the analysis of 11 phthalates in four types of beverage samples.
引用
收藏
页码:1624 / 1631
页数:8
相关论文
共 50 条
  • [31] A LABORATORY EXPERIMENT FOR THE ANALYSIS OF CAFFEINE IN NONALCOHOLIC BEVERAGES BY SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LIEU, VT
    KALBUS, GE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 110 - CHED
  • [32] Determination of momordicoside A in bitter melon by high-performance liquid chromatography after solid-phase extraction
    Shui Wang
    Lin Tang
    Yiran Guo
    Fang Yan
    Fang Chen
    Chromatographia, 2001, 53 : 372 - 374
  • [33] Determination of methylparaben in o/w emulsions by solid-phase extraction and high-performance liquid chromatography
    Pongcharoenkiat, N
    Wittayanukulluk, A
    Hem, SL
    JOURNAL OF COSMETIC SCIENCE, 2003, 54 (01) : 47 - 52
  • [34] Determination of sulfophenylcarboxylic acids in marine samples by solid-phase extraction then high-performance liquid chromatography
    V. León
    A. Gómez-Parra
    E. González-Mazo
    Fresenius' Journal of Analytical Chemistry, 2001, 371 : 479 - 485
  • [35] Determination of celecoxib in human plasma using solid-phase extraction and high-performance liquid chromatography
    Chow, HHS
    Anavy, N
    Salazar, D
    Frank, DH
    Alberts, DS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 167 - 174
  • [36] Determination of rotenone residues in raw honey by solid-phase extraction and high-performance liquid chromatography
    Jiménez, JJ
    Bernal, JL
    del Nozal, MJ
    Novo, M
    Higes, M
    Llorente, J
    JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) : 67 - 73
  • [37] Determination of noscapine in human plasma using solid-phase extraction and high-performance liquid chromatography
    Chollet, DF
    Ruols, C
    Arnera, V
    JOURNAL OF CHROMATOGRAPHY B, 1997, 701 (01): : 81 - 85
  • [38] DETERMINATION OF GLICLAZIDE IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLID-PHASE EXTRACTION
    NOGUCHI, H
    TOMITA, N
    NARUTO, S
    NAKANO, S
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 583 (02): : 266 - 269
  • [39] High-performance liquid chromatography with solid-phase extraction for the quantitative determination of nilotinib in human plasma
    Miura, Masatomo
    Takahashi, Naoto
    Sawada, Ken-ichi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (07) : 789 - 793
  • [40] Determination of ketamine and norketamine enantiomers in plasma by solid-phase extraction and high-performance liquid chromatography
    Svensson, JO
    Gustafsson, LL
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02): : 373 - 376