Determination of 11 Phthalate Esters in Beverages by Magnetic Solid-Phase Extraction Combined with High-Performance Liquid Chromatography

被引:0
作者
Yin, Shuo [1 ]
Yang, Yi [1 ]
Yang, Danni [1 ]
Li, Yongxin [1 ,2 ]
Jiang, Yang [3 ]
Wu, Ling [1 ]
Sun, Chengjun [1 ,2 ]
机构
[1] Sichuan Univ, West China Sch Publ Hlth, Chengdu 610041, Sichuan, Peoples R China
[2] Prov Key Lab Food Safety Monitoring & Risk Assess, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Prov Ctr Dis Control & Prevent, Chengdu 610041, Sichuan, Peoples R China
关键词
ENVIRONMENTAL WATER; BOTTLED WATER; ACID-ESTERS; NANOPARTICLES; SAMPLES; MICROEXTRACTION; ADSORBENTS;
D O I
10.1093/jaoac/102.5.1624
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Beverages can be easily contaminated by phthalate esters (PAEs) during the production, bottling, and transportation processes. It is necessary to determine the contamination level in beverages for assessment of human exposure. Objective: In this study, magnetic solid-phase extraction (MSPE) was combined with HPLC for the determination of 11 PAEs in beverages. Methods: Self-synthesized magnetic multiwalled carbon nanotubes (m-MWCNTs) were used as the adsorbent for PAE extraction. To extract the PAEs, an appropriate amount of m-MWCNTs and NaCl was added to the beverage sample. The mixture was mixed on a vortex mixer, the magnetic sorbent was collected with the aid of a magnet, and the supernatant was removed. Then, the analytes were eluted with n-hexane acetone (1+1, v/v). Finally, the eluent was analyzed by the HPLC method. The separation was accomplished on a Phenomenex Luna-C18 column (250 x 4.6 mm, 5 mu m), and the detection wavelength was set at 225 nm. Results: The linear ranges of the method were 2-300 mu g/L with correlation coefficients greater than 0.9981. The LOD and LOQ were in the range of 0.659-5.33 x 10(-2) mu g/L and 2.20-17.8 x 10(-2) mu g/L, respectively. The recoveries of the method ranged from 79.8 to 114%, with the relative SDs less than 15.8%. The established method has been successfully applied for the determination of 11 PAEs in mineral water, carbonated soft drink, tea beverage, and fruit juice samples. PAEs were detected at 0.246-34.3 mu g/L in these samples. Conclusions: The m-MWCNTs are the satisfactory sorbent for MSPE because of their strong adsorption capacity for PAEs. The established MSPE-HPLC method is rapid, easy, sensitive, green, and cost-effective. It can be applied to the analysis of trace PAEs in plastic bottled beverages. Highlights: Three magnetic nanoparticles (MNPs), including Fe3O4 MNPs, m-MWCNTs, and magnetic graphene oxide, were synthesized, and m-MWCNTs were chosen as the sorbent of MSPE for PAE extraction because of their strong adsorption capacity for PAEs. An MSPE HPLC method has been developed for the analysis of 11 phthalates in plastic bottled beverages. The established method was successfully applied to the analysis of 11 phthalates in four types of beverage samples.
引用
收藏
页码:1624 / 1631
页数:8
相关论文
共 37 条
[1]  
[Anonymous], 1995, 506 US EPA
[2]   Novel Functionalized Polythiophene-Coated Fe3O4 Nanoparticles for Magnetic Solid-Phase Extraction of Phthalates [J].
Baharin, Siti Nor Atika ;
Sarih, Norazilawati Muhamad ;
Mohamad, Sharifah .
POLYMERS, 2016, 8 (05)
[3]   Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
Zhou, QX .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :149-156
[4]   Determination of Phthalates in Beverages by Headspace SPME-GC Using Calix[6]arene Fiber [J].
Chen, Hao ;
Liu, Xiao-Jing ;
Yang, Cai ;
Gao, Jie ;
Ye, Chang-Wen ;
Li, Xiu-Juan .
CHROMATOGRAPHIA, 2009, 70 (5-6) :883-890
[5]   Monodisperse magnetic single-crystal ferrite microspheres [J].
Deng, H ;
Li, XL ;
Peng, Q ;
Wang, X ;
Chen, JP ;
Li, YD .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (18) :2782-2785
[6]   Analytical methods for the determination of phthalates in food [J].
Gonzalez-Salamo, Javier ;
Socas-Rodriguez, Barbara ;
Hernandez-Borges, Javier .
CURRENT OPINION IN FOOD SCIENCE, 2018, 22 :122-136
[7]   Determination of phthalates in beverages using multiwalled carbon nanotubes dispersive solid-phase extraction before HPLC-MS [J].
Gonzalez-Salamo, Javier ;
Hernandez-Borges, Javier ;
del Mar Afonso, Maria ;
Angel Rodriguez-Delgado, Miguel .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (12) :2613-2622
[8]   Phthalates: Toxicology and exposure [J].
Heudorf, Ursel ;
Mersch-Sundermann, Volker ;
Angerer, Juergen .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2007, 210 (05) :623-634
[9]   Phthalate Risks, Phthalate Regulation, and Public Health: A Review [J].
Kamrin, Michael A. .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART B-CRITICAL REVIEWS, 2009, 12 (02) :157-174
[10]   Hollow fiber stir bar sorptive extraction for determination of phthalic acid esters in environmental and biological matrices [J].
Li, Jia ;
Wang, Yan-Bin ;
Su, Qiong ;
Wu, Shang ;
Wu, Lan .
JOURNAL OF SEPARATION SCIENCE, 2017, 40 (04) :893-900