摘要
Background. Previous studies have analyzed the efficacy of crystalloid cardioplegic solutions, but the use of Celsior (Genzyme Corp, Boston, MA) as a crystalloid cardioplegic solution has not been evaluated. Methods. In this observational retrospective study, Celsior crystalloid solution was compared with an all-blood continuous myocardial protection (microplegia). The study included all patients who underwent elective aortic valve replacement operations in whom the myocardial protection was Celsior or microplegia. The primary end points were surrogates of myocardial protection and death at 30 days. The secondary end point was the safety analysis of the use of Celsior. Results. The study included 631 patients, divided in two groups: 219 (34.7%) with microplegia and 412 (65.3%) with Celsior. Troponin T release accurately predicted postoperative death (area under the receiver operating characteristic curve = 0.85). Troponin T increased with the duration of clamp time, and the adjusted time-related increase was lower in the Celsior group. There were no statistically significant differences in the postoperative use of inotropic medication or intraaortic balloon pump. Adjusted postoperative death was lower in Celsior group (odds ratio, 0.33; 95% confidence interval, 0.15 to 0.76). There were no allergic reactions attributed to Celsior and no unexpected toxicity with the use of Celsior (coagulopathy, renal dysfunction, liver dysfunction, or encephalopathy). Conclusions. Isolated crystalloid Celsior may be an optimal and safe myocardial protection strategy in aortic valve replacement operations. (C) 2017 by The Society of Thoracic Surgeons
引用
收藏
页码:25 / 31
页数:7
相关论文
共 21 条
[1]   Celsior versus custodiol:: Early postischemic recovery after cardioplegia and ischemia at 50°C [J].
Ackemann, J ;
Gross, W ;
Mory, M ;
Schaefer, M ;
Gebhard, MM .
ANNALS OF THORACIC SURGERY, 2002, 74 (02) :522-529
[2]   Prognostic significance of elevated cardiac troponin I after heart surgery [J].
Adabag, A. Selcuk ;
Rector, Thomas ;
Mithani, Salima ;
Harmala, John ;
Ward, Herbert B. ;
Kelly, Rosemary F. ;
Nguyen, John T. ;
McFalls, Edward O. ;
Bloomfield, Hanna E. .
ANNALS OF THORACIC SURGERY, 2007, 83 (05) :1744-1750
[3]  
Albacker Turki B, 2009, Interact Cardiovasc Thorac Surg, V9, P56, DOI 10.1510/icvts.2009.204990
[4]  
Bernabeu E, 2015, J CARDIOTHORAC SU S1, V10, pA60
[6]   Evidence-based medicine and myocardial protection where is the evidence? [J].
Ferguson, Z. G. ;
Yarborough, D. E. ;
Jarvis, B. L. ;
Sistino, J. J. .
PERFUSION-UK, 2015, 30 (05) :415-422
[7]   Myocardial damage following cardiac surgery: comparison between single-dose Celsior cardioplegic solution and cold blood multi-dose cardioplegia [J].
Giordano, P. ;
Scrascia, G. ;
D'Agostino, D. ;
Mastro, F. ;
Rotunno, C. ;
Conte, M. ;
Rociola, R. ;
Paparella, D. .
PERFUSION-UK, 2013, 28 (06) :496-503
[8]   Is blood superior to crystalloid cardioplegia? A meta-analysis of randomized clinical trials [J].
Guru, Veena ;
Omura, John ;
Alghamdi, Abdullah A. ;
Weisel, Richard ;
Fremes, Stephen E. .
CIRCULATION, 2006, 114 :I331-I338
[9]  
Jacob Samuel, 2008, Interact Cardiovasc Thorac Surg, V7, P491, DOI 10.1510/icvts.2008.178343
[10]   A survey of current myocardial protection practices during coronary artery bypass grafting [J].
Karthik, S ;
Grayson, AD ;
Oo, AY ;
Fabri, BM .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2004, 86 (06) :413-415