Influence of implant surface topography on bone-regenerative potential and mechanical retention in the human maxilla and mandible

被引:0
作者
Wei, Niu [1 ,2 ]
Bin, Shi [3 ]
Jing, Zhou [2 ]
Wei, Sun [2 ]
Yingqiong, Zhao [2 ]
机构
[1] Wuhan Univ, Hosp Stomatol, Wuhan 430079, Peoples R China
[2] Stomatol Hosp ChangSha, Dept Prosthodont, Changsha, Hunan, Peoples R China
[3] Wuhan Univ, Hosp Stomatol, Dept Implant Ctr, Wuhan 430079, Peoples R China
关键词
TITANIUM IMPLANTS; HISTOLOGIC EVALUATION; HISTOMORPHOMETRIC ANALYSIS; SHAPED IMPLANTS; REMOVAL TORQUE; ROUGHNESS; ATTACHMENT; CONTACT; CELLS; PROLIFERATION;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the short- and mid-term effects of commercial pure (cp) titanium implant surface topography on osseointegration, bone-regenerative potential and mechanical retention in the human maxilla and mandible. Methods: 32 micro-implants with the same geometry but with four different surface treatments were implanted in the maxilla and mandible of eight patients. Each patient received four micro-implants, one of each type. Percentage of bone-to-implant contact analysis and histological evaluation was carried 3, 6 and 12 weeks after implantation. Furthermore, reverse removal torque tests were conducted 3 and 6 weeks after implantation to analyze functional bone attachment. Implant surfaces tested were machined, grit-blasted, acid-etched, and grit-blasted with acid-etch. One-way ANOVA was performed using the multiple comparison Fisher's test to determine significance of observed differences among test groups. The level of significance was established at 5% (P< 0.05). Mean and standard deviations of the test groups were calculated. Results: Surface roughness had a significant correlation with the evolution of bone regeneration. The surfaces with roughness Ra approximate to 4 mu m (grit-blasted and grit-blasted with acid-etch), showed rapid tissue colonization compared to machine and acid-etched surfaces. The results of reverse removal torque tests confirmed a significant correlation between surface roughness and functional bone attachment. Grit-blasted and grit-blasted with acid etched surfaces showed higher retention values compared to machine and acid-etched implants. This finding was supported by higher bone-to-implant contact observed for rougher surfaces (grit-blasted and grit-blasted with acid etching).
引用
收藏
页码:171 / 176
页数:6
相关论文
共 33 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]  
Bowers K T, 1992, Int J Oral Maxillofac Implants, V7, P302
[3]  
Boyan BD, 1998, J BIOMED MATER RES, V39, P77, DOI 10.1002/(SICI)1097-4636(199801)39:1<77::AID-JBM10>3.0.CO
[4]  
2-L
[5]  
Brunette D M, 1988, Int J Oral Maxillofac Implants, V3, P231
[6]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[7]   Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants [J].
Buser, D ;
MericskeStern, R ;
Bernard, JP ;
Behneke, A ;
Behneke, N ;
Hirt, HP ;
Belser, UC ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :161-172
[8]  
BUSER D, 2001, ENG MATER, P875
[9]  
Carlsson L, 1995, CLIN ORAL IMPLAN RES, V6, P24
[10]   Topographical control of cells [J].
Curtis, A ;
Wilkinson, C .
BIOMATERIALS, 1997, 18 (24) :1573-1583