Platelet microparticle generation assay: A valuable test for immune heparin-induced thrombocytopenia diagnosis

被引:30
作者
Mullier, F. [1 ,2 ,3 ]
Minet, V. [2 ]
Bailly, N. [1 ]
Devalet, B. [3 ,4 ]
Douxfils, J. [2 ,3 ]
Chatelain, C. [3 ,4 ]
Elalamy, I. [5 ]
Dogne, J. M. [2 ,3 ]
Chatelain, B. [1 ,3 ]
机构
[1] CHU Dinant Godinne UCL Namur, Hematol Lab, Namur Res Inst LIfe Sci NARILIS, B-5530 Yvoir, Belgium
[2] Univ Namur, Dept Pharm, Namur Res Inst LIfe Sci NARILIS, Namur, Belgium
[3] Namur Thrombosis & Hemostasis Ctr NTHC, Namur, Belgium
[4] CHU Dinant Godinne UCL Namur, Dept Hematol, Namur Res Inst LIfe Sci NARILIS, B-5530 Yvoir, Belgium
[5] Hop Tenon, Dept Hematol, F-75970 Paris, France
关键词
thrombosis; microparticles; heparin-induced thrombocytopenia; platelets; MULTIPLE ELECTRODE AGGREGOMETRY; SEROTONIN RELEASE ASSAY; CIRCULATING MICROPARTICLES; CALIBRATED BEADS; FLOW-CYTOMETRY; STANDARDIZATION; TOOL; ISSUES; SCORE; HIT;
D O I
10.1016/j.thromres.2013.12.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Early diagnosis of immune heparin-induced thrombocytopenia (HIT) is essential to improve clinical outcome but remains challenging. The release of platelet microparticles (PMPs) is considered of major pathophysiological significance. Objectives: The aim of this study was to evaluate performances of PMP generation assay (PMPGA) compared to clinical outcome to diagnose HIT. The second objective was to compare PMPGA with performances of C-14-serotonin release assay (SRA) on the same series of patients. Methods: Sera of 53 HIT-suspected patients were retrospectively incubated with citrated-whole blood from healthy donors with 1 IU and 500 IU/ml of unfractionated heparin (UH). PMPGA was performed using FACSAria (R) flow cytometer. The clinical diagnosis was established by two blinded independent investigators analysing in a standardized manner the patient's medical records. Performances of PMPGA and SRA (n = 53) were evaluated using ROC curve analysis with clinical outcome as reference. Results: In positive HIT patients, PMPs expressing phosphatidylserine are generated with low UH concentration whereas PMP rate decreases significantly in presence of high UH concentration. Using clinical outcome as reference, sensitivity and specificity of PMPGA reached 88.9% (95% CI: 50.7-99.4) and 100.0% (95% CI: 90.0-100.0). Sensitivity and specificity of C-14-SRA were 88.9% (95% CI: 50.7-99.4) and 95.5% (95% CI: 83.3-99.2). Conclusions: PMPGA is a rapid and reliable assay for HIT diagnosis. PMPGA showed good correlation with C-14-SRA performances and predominately with clinical outcome. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1068 / 1073
页数:6
相关论文
共 37 条
  • [1] [Anonymous], CHEST S
  • [2] [Anonymous], J THROMB HAEMOST
  • [3] A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometer
    Chandler, W. L.
    Yeung, W.
    Tait, J. F.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (06) : 1216 - 1224
  • [4] The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion
    Cuker, A.
    Arepally, G.
    Crowther, M. A.
    Rice, L.
    Datko, F.
    Hook, K.
    Propert, K. J.
    Kuter, D. J.
    Ortel, T. L.
    Konkle, B. A.
    Cines, D. B.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (12) : 2642 - 2650
  • [5] Cuker Adam, 2009, Hematology Am Soc Hematol Educ Program, P250, DOI 10.1182/asheducation-2009.1.250
  • [6] A clinical-laboratory approach contributing to a rapid and reliable diagnosis of heparin-induced thrombocytopenia
    Denys, Barbara
    Stove, Veronique
    Philippe, Jan
    Devreese, Katrien
    [J]. THROMBOSIS RESEARCH, 2008, 123 (01) : 137 - 145
  • [7] Heparin-induced multiple electrode aggregometry: a potential tool for improvement of heparin-induced thrombocytopenia diagnosis
    Elalamy, I.
    Galea, V.
    Hatmi, M.
    Gerotziafas, G. T.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (11) : 1932 - 1934
  • [8] Detection and measurement of microparticles: An evolving research tool for vascular biology
    Enjeti, Anoop K.
    Lincz, Lisa F.
    Seldon, Michael
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2007, 33 (08) : 771 - 779
  • [9] Heparin-induced multiple electrode aggregometry is a promising and useful functional tool for heparin-induced thrombocytopenia diagnosis: Confirmation in a prospective study
    Galea, Vassiliki
    Khaterchi, Amir
    Robert, Francoise
    Gerotziafas, Grigoris
    Hatmi, Mohamed
    Elalamy, Ismail
    [J]. PLATELETS, 2013, 24 (06) : 441 - 447
  • [10] Heparin-induced thrombocytopenia: towards standardization of platelet factor 4/heparin antigen tests
    Greinacher, A.
    Ittermann, T.
    Bagemuehl, J.
    Althaus, K.
    Fuerll, B.
    Selleng, S.
    Lubenow, N.
    Schellong, S.
    Sheppard, J. I.
    Warkentin, T. E.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (09) : 2025 - 2031