Effect of pressure on the chromatographic separation of enantiomers under reversed-phase conditions

被引:6
作者
Makaroy, Alexey A. [1 ]
Regalado, Erik L. [1 ]
Welch, Christopher J. [1 ]
Schafer, Wes A. [1 ]
机构
[1] Merck Sharp & Dohme Corp, Merck Res Labs, Rahway, NJ 07065 USA
关键词
Pressure; Enantiomer; Chiral; Ultra high pressure LC; UHPLC; LIQUID-CHROMATOGRAPHY; CHIRAL RECOGNITION; RETENTION PROPERTIES; SMALL MOLECULES; MOLAR VOLUME; TEMPERATURE; PERFORMANCE; MIXTURES; ACETONITRILE; MECHANISMS;
D O I
10.1016/j.chroma.2014.05.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Commercially available ultra high pressure liquid chromatography (UHPLC) equipment offers the ability to explore the influence of backpressure on chromatographic separations. However, the influence of pressure on the chromatographic separation of enantiomers on chiral stationary phases remains largely unexplored. In this investigation we surveyed the effects of pressure on the separation of enantiomers using several reversed-phase chiral stationary phases. The experiments were conducted at constant flow rate and column temperature, using isocratic conditions. The only variable parameter was pressure, which was adjusted using a post-column backpressure regulator. For the separation of enantiomers on chiral stationary phases, an increase in pressure from approximately 2000 psi (138 bar) to approximately 8000 psi (552 bar) at constant flow rate and temperature led to an increase of retention factors for some analytes and a decrease for others. Achiral separations on a C-18 stationary phase always led only to an increase of retention factor. Interestingly, changes in pressure led to small changes in enantioselectivity during reversed-phase chiral separation of enantiomers, suggesting that such studies may be of value for better understanding the mechanisms underlying chromatographic enantioseparation. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 32 条
[1]  
Aboul-Enein H.Y., 1997, IMPACT STEREOCHEMIST
[2]   A thermodynamic study on binary and ternary mixtures of acetonitrile, water and butyl acetate [J].
Acosta, J ;
Arce, A ;
Rodil, E ;
Soto, A .
FLUID PHASE EQUILIBRIA, 2002, 203 (1-2) :83-98
[3]  
Allenmark S.G., 1991, CHROMATOGRAPHIC ENAN
[4]  
[Anonymous], 1978, PHYS CHEM
[5]  
[Anonymous], 2012, VERS 12 02 CALC LIB
[6]   Chiral recognition mechanisms [J].
Berthod, A .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2093-2099
[7]   Investigation of the validity of the kinetic plot method to predict the performance of coupled column systems operated at very high pressures under different thermal conditions [J].
Cabooter, Deirdre ;
Lestremau, Francois ;
de Villiers, Andre ;
Broeckhoven, Ken ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :3895-3903
[8]   Pressure-induced retention of the lysozyme on reversed-phase liquid chromatography [J].
Chen, SH ;
Ho, CT ;
Hsiao, KY ;
Chen, JM .
JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (02) :207-215
[9]   Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1 mm ID columns [J].
de Villiers, A ;
Lauer, H ;
Szucs, R ;
Goodall, S ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1113 (1-2) :84-91
[10]   Investigation of the effect of pressure on retention of small molecules using reversed-phase ultra-high-pressure liquid chromatography [J].
Fallas, Morgane M. ;
Neue, Uwe D. ;
Hadley, Mark R. ;
McCalley, David V. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) :195-205