Secondary Arc and Critical Time of Fault Clearance in Overhead Lines

被引:15
作者
Arias Velasquez, R. M. [1 ]
Mejia Lara, J. V. [1 ]
机构
[1] PUCP, Lima, Peru
关键词
Arc; critical time; stability; protection schemes; overhead lines; FAILURE;
D O I
10.1109/TLA.2018.8358666
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This research presents a methodology for the creation of a novel computational algorithm, which allowed the automation of the simulation activities associated to the determination of critical times of fault clearance in the Peruvian National Interconnected System. For its development, interesting iterative stability analyzes were carried out and Ward reductions were introduced to the network model of the Peruvian electrical system. The above, in order to obtain adequate processing times, in such a way that this algorithm was applicable to the analysis of planning and operation of the power system. The secondary arc model has been developed using MODELS in ATP, which brings together the strengths of the main existing models and implements a pseudorandom variation of the secondary arc length, in order to provide accurate results for the determination of extinction times of Secondary arch in studies of monopolar reclosures. The approach of the developed model also proposes a methodology in which the extinction times are obtained as the result of a statistical simulation. The comparison of the proposed model with cases of studies of the double circuit line 500 kV with satisfactory results was carried out.
引用
收藏
页码:859 / 868
页数:10
相关论文
共 24 条
[1]   Snubber resistor influence in the thyristor valves failure on the static VAR compensator [J].
Arias Velasquez, Ricardo Manuel ;
Mejia Lara, Jennifer Vanessa .
ENGINEERING FAILURE ANALYSIS, 2018, 89 :150-176
[2]   Ruptures in overhead ground wire - Transmission line 220 kV [J].
Arias Velasquez, Ricardo Manuel ;
Mejia Lara, Jennifer Vanessa .
ENGINEERING FAILURE ANALYSIS, 2018, 87 :1-14
[3]   Life estimation of shunt power reactors considering a failure core heating by floating potentials [J].
Arias Velasquez, Ricardo Manuel ;
Mejia Lara, Jennifer Vanessa .
ENGINEERING FAILURE ANALYSIS, 2018, 86 :142-157
[4]   The need of creating a new nominal creepage distance in accordance with heaviest pollution 500 kV overhead line insulators [J].
Arias Velasquez, Ricardo Manuel ;
Mejia Lara, Jennifer Vanessa .
ENGINEERING FAILURE ANALYSIS, 2018, 86 :21-32
[5]   Reliability, availability and maintainability study for failure analysis in series capacitor bank [J].
Arias Velasquez, Ricardo Manuel ;
Mejia Lara, Jennifer Vanessa .
ENGINEERING FAILURE ANALYSIS, 2018, 86 :158-167
[6]  
Comite de Operacion Economico del Sistema (COES), 2015, PROC PR 20
[7]  
di Salvo J. H., 1997, ESTUDIO ARCO SECUNDA
[8]  
Goldeberg S, 1989, IEEE T POWER DELIVER, V4
[9]  
Ingenieria Especializada S. A., 2013, P1SE16D016
[10]  
Johns A. T, 1984, IEEE T POWER APPARAT, V103