Shutter control for cooling air flow management in data center servers

被引:0
作者
Noguchi, Tomomichi [1 ]
Wijekoon, Janaka [1 ]
Joshi, Yogendra [2 ]
Yoda, Minami [2 ]
Nishi, Hiroaki [1 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Kohoku Ku, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[2] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
来源
PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY | 2016年
关键词
data center; cooling efficiency; air conditioning; air flow control; RACK;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The growth of energy consumption in data centers is becoming one of the significant problems all over the world. The power usage of IT devices and air-conditioning (AC) units accounts for up to three-quarters of total energy consumption in typical data centers. This study discusses the effectiveness of using shutter-controlled air flow management to control cold air flow into the servers. It can impact the power consumption of both, the servers and the AC units. A raised floor data center has two types of aisles - cold and hot. In most cases, excessive volumes of cold air are pumped into the servers using cold aisles. We are proposing the utilization of a shutter to control the air flow and reduce wastage while preventing damage due to increased CPU temperature. The shutter is intended to control the air flow and maintain the temperature appropriately according to the workload of the servers. We evaluated the proposed system for controlling the flow of air into the servers. The results show that cold air volumes can be reduced by up to 92% while maintaining appropriate control of CPU temperature.
引用
收藏
页码:5591 / 5596
页数:6
相关论文
共 22 条
  • [1] Ahmad F, 2010, ASPLOS XV: FIFTEENTH INTERNATIONAL CONFERENCE ON ARCHITECTURAL SUPPORT FOR PROGRAMMING LANGUAGES AND OPERATING SYSTEMS, P243
  • [2] Alkharabsheh S, 2014, INTSOC CONF THERMAL, P1338, DOI 10.1109/ITHERM.2014.6892435
  • [3] [Anonymous], 2011, P 2 ACM SIGCOMM WORK
  • [4] [Anonymous], 2011 IEEE INT C COMM
  • [5] Experimental Investigation of Air Flow Through a Perforated Tile in a Raised Floor Data Center
    Arghode, Vaibhav K.
    Joshi, Yogendra
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2015, 137 (01)
  • [6] Arghode Vaibhav K., INT MECH ENG C EXP I, P1059
  • [7] Optimization of data center room layout to minimize rack inlet air temperature
    Bhopte, Siddharth
    Agonafer, Dereje
    Schmidt, Roger
    Sammakia, Bahgat
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2006, 128 (04) : 380 - 387
  • [8] Cole Dave, 2012, DATA CTR KNOWLEDGE G
  • [9] Fan XB, 2007, CONF PROC INT SYMP C, P13, DOI 10.1145/1273440.1250665
  • [10] Integrating adaptive components: An emerging challenge in performance-adaptive systems and a server farm case-study
    Heo, Jin
    Henriksson, Dan
    Liu, Xue
    Abdelzaher, Tarek
    [J]. RTSS 2007: 28TH IEEE INTERNATIONAL REAL-TIME SYSTEMS SYMPOSIUM, PROCEEDINGS, 2007, : 227 - +