HD2 reduction technique for single-ended amplifier

被引:1
作者
Sharma, S. [1 ]
Khandelwal, S. [2 ]
Ytterdal, T. [1 ]
Niknejad, A. M. [2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Elect & Telecommun, N-7034 Trondheim, Norway
[2] Univ Calif Berkeley, Elect Engn & Comp Sci, Berkeley, CA 94720 USA
关键词
Amplifiers; (electronic);
D O I
10.1049/el.2015.3306
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new technique for second harmonic distortion (HD2) reduction is presented. The proposed technique can be very useful for front-end receiver applications where single-ended high-gain, low-distortion amplifiers are required. The theoretical analysis and simulations of this scheme in which the second derivative of the current can be cancelled by using an extra transistor biased in the triode region in parallel to a MOSFET in saturation is presented. This technique is also robust to process variations as a result of the use of a tuning voltage in the proposed design. A 9 dB reduction in the magnitude of HD2 has been achieved with this technique compared with an amplifier of similar power consumption. This technique can be used in a design without significant impact on area, power or noise performance.
引用
收藏
页码:2091 / 2092
页数:2
相关论文
共 4 条
[1]  
[Anonymous], 2013, BSIM4 TECHN MAN
[2]  
AVERKIOU MA, 1997, P IEEE ULTR S, P1561
[3]   Tissue harmonic imaging [J].
Whittingham, TA .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S323-S326
[4]  
Yetterdal T., 2003, DEVICE MODELING ANAL