摘要
Introduction: The aim of this study was to evaluate and compare, by means of micro computed tomography imaging, the shaping ability of ProTaper Next (PTN) and the novel HyFlex EDM (HFEDM) instruments. Methods: Forty teeth were randomly divided into 2 groups and prepared with PTN or HFEDM. Root canal transportation and centering ratio were evaluated in mesiodistal and buccolingual directions at 5 levels (at the midpoint of the apical, middle, and coronal thirds and at the boundaries between them). Variations in volume, surface, and cross-sectional shape were measured for the apical, middle, and coronal thirds. The null hypotheses were that no differences existed between the 2 groups. The D'Agostino-Pearson test (alpha = .05) was conducted to assess the normality of the data sets. The distributions were compared by using the Mann-Whitney test (alpha = .05). Results: Statistically significant differences (P < .005) were recorded only for buccolingual canal transportation and centering ratio at the section between the middle and coronal thirds, where HFEDM files were superior. Conclusions: HFEDM and PTN files were similarly effective, and both safely prepared the root canals, respecting their original anatomies. HFEDM files performed better in terms of buccolingual canal transportation and centering ratio at the section between the middle and coronal thirds.
引用
收藏
页码:628 / 632
页数:5
相关论文
共 35 条
[1]   Shaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals [J].
Buerklein, S. ;
Mathey, D. ;
Schaefer, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (08) :774-781
[2]   Effects of ProTaper Universal, ProTaper Next, and HyFlex Instruments on Crack Formation in Dentin [J].
Capar, Ismail Davut ;
Arslan, Hakan ;
Akcay, Merve ;
Uysal, Banu .
JOURNAL OF ENDODONTICS, 2014, 40 (09) :1482-1484
[3]   Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals [J].
Capar, Ismail Davut ;
Ertas, Huseyin ;
Ok, Evren ;
Arslan, Hakan ;
Ertas, Elif Tarim .
JOURNAL OF ENDODONTICS, 2014, 40 (06) :852-856
[4]  
CAPUTO AA, 1976, DENT CLIN N AM, V20, P299
[5]   Comparative evaluation of shaping ability of two nickel-titanium rotary systems using cone beam computed tomography [J].
Celikten, Berkan ;
Uzuntas, Ceren Feriha ;
Kursun, Sebnem ;
Orhan, Ayse Isil ;
Tufenkci, Pelin ;
Orhan, Kaan ;
Demiralp, Kemal Ozgur .
BMC ORAL HEALTH, 2015, 15
[6]   Evaluation of Microcrack Formation in Root Canals After Instrumentation With different NiTi Rotary File Systems: A Scanning Electron Microscopy Study [J].
Cicek, Ersan ;
Kocak, Mustafa Murat ;
Saglam, Baran Can ;
Kocak, Sibel .
SCANNING, 2015, 37 (01) :49-53
[7]  
Coltene, 2015, NEW NIT FIL GEN HYFL
[8]   Micro-Computed Tomographic Evaluation of 2 Nickel-Titanium Instrument Systems in Shaping Root Canals [J].
da Silva Limoeiro, Ana Grasiela ;
Braitt dos Santos, Antonio Henrique ;
De Martin, Alexandre Sigrist ;
Kato, Augusto Shoji ;
Fontana, Carlos Eduardo ;
Gavini, Giulio ;
Freire, Laila Gonzales ;
da Silveira Bueno, Carlos Eduardo .
JOURNAL OF ENDODONTICS, 2016, 42 (03) :496-499
[9]   Evaluation of the Shaping Characteristics of ProTaper Gold, ProTaper NEXT, and Pro Taper Universal in Curved Canals [J].
Gagliardi, Jason ;
Versiani, Marco Aurelio ;
de Sousa-Neto, Manoel Damiao ;
Plazas-Garzon, Andres ;
Basrani, Bettina .
JOURNAL OF ENDODONTICS, 2015, 41 (10) :1718-1724
[10]   Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography [J].
Gambill, JM ;
Alder, M ;
delRio, CE .
JOURNAL OF ENDODONTICS, 1996, 22 (07) :369-375