Quantitative Ultrasound Imaging for Monitoring In Situ High-Intensity Focused Ultrasound Exposure

被引:17
作者
Ghoshal, Goutam [1 ,2 ]
Kemmerer, Jeremy P. [2 ]
Karunakaran, Chandra [2 ]
Abuhabsah, Rami [2 ]
Miller, Rita J. [2 ]
Sarwate, Sandhya [2 ]
Oelze, Michael L. [2 ]
机构
[1] Acoust MedSyst Inc, Savoy, IL USA
[2] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
关键词
quantitative ultrasound imaging; HIFU; effective scatterer diameter; effective scatterer concentration; parametric imaging; NONINVASIVE TEMPERATURE ESTIMATION; TISSUE TEMPERATURE; PROPAGATION SPEED; VIVO; ATTENUATION; BACKSCATTER; DEPENDENCE; FEASIBILITY; THERAPY; PHANTOM;
D O I
10.1177/0161734614524179
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantitative ultrasound (QUS) imaging is hypothesized to map temperature elevations induced in tissue with high spatial and temporal resolution. To test this hypothesis, QUS techniques were examined to monitor high-intensity focused ultrasound (HIFU) exposure of tissue. In situ experiments were conducted on mammary adenocarcinoma tumors grown in rats and lesions were formed using a HIFU system. A thermocouple was inserted into the tumor to provide estimates of temperature at one location. Backscattered time-domain waveforms from the tissue during exposure were recorded using a clinical ultrasonic imaging system. Backscatter coefficients were estimated using a reference phantom technique. Two parameters were estimated from the backscatter coefficient (effective scatterer diameter (ESD) and effective acoustic concentration (EAC). The changes in the average parameters in the regions corresponding to the HIFU focus over time were correlated to the temperature readings from the thermocouple. The changes in the EAC parameter were consistently correlated to temperature during both heating and cooling of the tumors. The changes in the ESD did not have a consistent trend with temperature. The mean ESD and EAC before exposure were 120 +/- 16 mm and 32 +/- 3 db/cm(3), respectively, and changed to 144 +/- 9 mm and 51 +/- 7 db/cm(3), respectively, just before the last HIFU pulse was delivered to the tissue. After the tissue cooled down to 37 degrees C, the mean ESD and EAC were 126 +/- 8 mm and 35 +/- 4 db/cm(3), respectively. Peak temperature in the range of 50-60 degrees C was recorded by a thermocouple placed just behind the tumor. These results suggest that QUS techniques have the potential to be used for non-invasive monitoring of HIFU exposure.
引用
收藏
页码:239 / 255
页数:17
相关论文
共 50 条
  • [41] High-intensity focused ultrasound therapy for prostate cancer
    Uchida, Toyoaki
    Nakano, Mayura
    Hongo, Satoko
    Shoji, Sunao
    Nagata, Yohishiro
    Satoh, Takefumi
    Baba, Shiro
    Usui, Yukio
    Terachi, Toshiro
    INTERNATIONAL JOURNAL OF UROLOGY, 2012, 19 (03) : 187 - 201
  • [42] Controlled Hyperthermia With High-Intensity Focused Ultrasound and Ultrasound Contrast Agent Microbubbles in Porcine Liver
    Juang, Eric K.
    Koninck, Lance H. De
    Vuong, Kaleb S.
    Gnanaskandan, Aswin
    Hsiao, Chao-Tsung
    Averkiou, Michalakis A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (08) : 1852 - 1860
  • [43] 2D ultrasound thermometry during thermal ablation with high-intensity focused ultrasound
    Rohfritsch, Adrien
    Barrere, Victor
    Estienne, Laura
    Melodelima, David
    ULTRASONICS, 2024, 142
  • [44] High intensity focused ultrasound: Imaging is the key!
    Shehata, I. A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2014, 95 (06) : 569 - 572
  • [45] Treatment of liver alveococcosis with high-intensity focused ultrasound
    Imankulov, S. B.
    Fedotovskikh, G. V.
    Zhampeissov, N. K.
    Yerlan, M.
    Shaimardanova, G. M.
    Knaub, L. V.
    ULTRASONICS SONOCHEMISTRY, 2015, 27 : 707 - 711
  • [46] Blood flow imaging using singular value decomposition filter during high-intensity focused ultrasound exposure
    Ikeda, Hayato
    Yoshizawa, Shin
    Maeda, Moe
    Umemura, Shin-ichiro
    Saijo, Yoshifumi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2019, 58 (SG)
  • [47] High-intensity focused ultrasound treatment for patients with unresectable pancreatic cancer
    Li, Peng-Zhou
    Zhu, Shai-Hong
    He, Wei
    Zhu, Li-Yong
    Liu, Sheng-Ping
    Liu, Yan
    Wang, Guo-Hui
    Ye, Fei
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2012, 11 (06) : 655 - 660
  • [48] Histological outcomes after focal high-intensity focused ultrasound and cryotherapy
    Shah, Taimur T.
    Kasivisvanathan, Veeru
    Jameson, Charles
    Freeman, Alex
    Emberton, Mark
    Ahmed, Hashim U.
    WORLD JOURNAL OF UROLOGY, 2015, 33 (07) : 955 - 964
  • [49] Advancements in high-intensity focused ultrasound for urological tumor research and application
    Liu, Jun
    Feng, You-Gang
    Zhang, Cai
    Chen, Wen-Zhi
    ANNALS OF MEDICINE AND SURGERY, 2025, 87 (04): : 2014 - 2019
  • [50] High-intensity focused ultrasound ablation in hepatic and pancreatic cancer: complications
    Jung, Seung Eun
    Cho, Se Hyun
    Jang, Jin Hee
    Han, Joon-Yeol
    ABDOMINAL IMAGING, 2011, 36 (02): : 185 - 195