Press-fit vs. cemented humeral stem fixation for reverse shoulder arthroplasty: functional outcomes at a mean follow-up of 9.5 years

被引:16
|
作者
Mazaleyrat, Matthieu [1 ,2 ]
Favard, Luc [1 ,2 ]
Garaud, Pascal [1 ,2 ]
Boileau, Pascal [3 ]
Berhouet, Julien [1 ,2 ]
机构
[1] CHRU Tours, Serv Chirurg Orthoped & Traumatol, Hop Trousseau, Chambray Les Tours, France
[2] Univ Tours, Fac Med, Ctr Val de Loire, Chambray Les Tours, France
[3] Hop Pasteur 2, Inst Univ Locomoteur & Sport, CHU Nice, Nice, France
关键词
Reverse shoulder arthroplasty; functional outcomes; humeral stem; cemented; press-fit; tuberosity resorption; osteolyse; radiolucent line; ROTATOR CUFF TEARS; REVISION;
D O I
10.1016/j.jse.2020.04.052
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reverse shoulder arthroplasty (RSA) is a reliable, long-term treatment option for degenerative shoulder pathology. However, the functional outcomes degrade around the fifth year postoperation, particularly for internal and external rotation. Long-term radiographic changes have been reported around the humeral stem, depending on the fixation method. Objectives: The primary objective was to compare the clinical outcomes of RSAs by fixation method-cemented vs. press-fit-after a minimum follow-up of 5 years. We hypothesized that proximal humeral osteolysis impacts the functional outcomes. Design and Methods: Our study compared 2 matched cohorts: 56 RSAs with cemented stems and 56 RSAs with press-fit stems. We evaluated all the patients using the Constant-Murley score (CMS) and range of motion (ROM), which we measured preoperatively and at the final follow-up visit. We evaluated radiographs from the final follow-up visit to look for proximal humeral osteolysis with tuberosity resorption, signs of stress shielding, periprosthetic radiolucent lines, and scapular notching. Results: At a mean follow-up of 9.5 years (5-21), regardless of the fixation method, the RSA procedure helped to improve the CMS and active joint ROM postoperatively, except for internal and external rotation with elbow at side in the press-fit group. Shoulder ROM was significantly better in the group with cemented stems for anterior elevation (P<.001), abduction (P=.006), and external (P=.02) and internal rotation with elbow at side (P=.02). The CMS did not differ between groups. The presence of tuberosity resorption or scapular notching had no effect on the CMS and active ROM in either group. Osteopenia, which was more prevalent in the press-fit group, had no impact on the functional outcome. Conclusion: There was no significant difference between groups in the CMS, although the active shoulder ROM was significantly worse in the press-fit group. This difference could be attributed to more frequent tuberosity resorption in this group. (C) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 30 条
  • [11] Radiographic evaluation of short-stem press-fit total shoulder arthroplasty: short-term follow-up
    Casagrande, Danielle J.
    Parks, Di L.
    Torngren, Travis
    Schrumpf, Mark A.
    Harmsen, Samuel M.
    Norris, Tom R.
    Kelly, James D., II
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (07) : 1163 - 1169
  • [12] Reverse shoulder arthroplasty vs BIO-RSA: clinical and radiographic outcomes at short term follow-up
    Kirzner, Nathan
    Paul, Eldho
    Moaveni, Ash
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [13] Patient satisfaction and clinical outcomes of reverse shoulder arthroplasty: a minimum of 10 years' follow-up
    Sheth, Mihir M.
    Heldt, Brett L.
    Spell, Jennifer H.
    Vidal, Emily A.
    Laughlin, Mitzi S.
    Morris, Brent J.
    Elkousy, Hussein A.
    Edwards, T. Bradley
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (04) : 875 - 883
  • [14] Reverse shoulder arthroplasty vs BIO-RSA: clinical and radiographic outcomes at short term follow-up
    Nathan Kirzner
    Eldho Paul
    Ash Moaveni
    Journal of Orthopaedic Surgery and Research, 13
  • [15] Reverse shoulder arthroplasty in 41 patients with cuff tear arthropathy with a mean follow-up period of 5 years
    Al-Hadithy, Nawfal
    Domos, Peter
    Sewell, Mathew D.
    Pandit, Ravi
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (11) : 1662 - 1668
  • [16] Bony increased-offset reverse shoulder arthroplasty vs. metal augments in reverse shoulder arthroplasty: a prospective, randomized clinical trial with 2-year follow-up
    Van de Kleut, Madeleine L.
    Yuan, Xunhua
    Teeter, Matthew G.
    Athwal, George S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (03) : 591 - 600
  • [17] Improved functional, radiographic and patient-reported outcomes at midterm follow-up for shoulder arthroplasty patients 75 years and older
    Gross, Benjamin D.
    Patel, Akshar V.
    Duey, Akiro H.
    Cirino, Carl M.
    Bernstein, Jordan D.
    White, Christopher A.
    Parsons, Bradford O.
    Flatow, Evan L.
    Cagle, Paul J.
    JOURNAL OF ORTHOPAEDICS, 2023, 45 : 19 - 25
  • [18] Effect of patient-reported allergies on reverse total shoulder arthroplasty outcomes at over two years follow-up
    Palosaari, Andrew A.
    White, Christopher A.
    Gross, Benjamin D.
    Patel, Akshar
    Li, Troy
    Flatow, Evan L.
    Cagle, Paul J.
    JOURNAL OF ORTHOPAEDICS, 2024, 51 : 87 - 90
  • [19] Neck shaft angle in reverse shoulder arthroplasty: 135 vs. 145 degrees at minimum 2-year follow-up
    Neyton, Lionel
    Nigues, Ana
    McBride, Andrew P.
    de Sanctis, Edoardo Giovannetti
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (07) : 1486 - 1493
  • [20] Clinical and radiological outcomes after reverse shoulder arthroplasty with less medialized endoprosthesis after mean follow-up time of 45 months
    Justinas Jonušas
    Rūta Banytė
    Sigitas Ryliškis
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1201 - 1205