Virtual clinical trial for quantifying the effects of beam collimation and pitch on image quality in computed tomography

被引:6
作者
Abadi, Ehsan [1 ]
Segars, William P. [1 ,2 ,3 ]
Harrawood, Brian [1 ]
Sharma, Shobhit [1 ,4 ]
Kapadia, Anuj [1 ,2 ,4 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ]
机构
[1] Duke Univ, Dept Radiol, Carl E Ravin Adv Imaging Labs, Sch Med, Durham, NC 27708 USA
[2] Duke Univ, Sch Med, Med Phys Grad Program, Durham, NC USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[4] Duke Univ, Dept Phys, Durham, NC 27706 USA
[5] Duke Univ, Dept Elect & Comp Engn, Durham, NC USA
基金
美国国家卫生研究院;
关键词
virtual clinical trial; simulation; computed tomography; computational human phantoms; CT simulator; in silico modeling; SPIRAL CT; RECONSTRUCTION; PHANTOMS; ARTIFACTS; ARTERIES; MOTION; SCAN;
D O I
10.1117/1.JMI.7.4.042806
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To utilize a virtual clinical trial (VCT) construct to investigate the effects of beam collimation and pitch on image quality (IQ) in computed tomography (CT) under different respiratory and cardiac motion rates. Approach: A computational human model [extended cardiac-torso (XCAT) phantom] with added lung lesions was used to simulate seven different rates of cardiac and respiratory motions. A validated CT simulator (DukeSim) was used in this study. A supplemental validation was done to ensure the accuracy of DukeSim across different pitches and beam collimations. Each XCAT phantom was imaged using the CT simulator at multiple pitches (0.5 to 1.5) and beam collimations (19.2 to 57.6 mm) at a constant dose level. The images were compared against the ground truth using three task-generic IQ metrics in the lungs. Additionally, the bias and variability in radiomics (morphological) feature measurements were quantified for task-specific lung lesion quantification across the studied imaging conditions. Results: All task-generic metrics degraded by 1.6% to 13.3% with increasing pitch. When imaged with motion, increasing pitch reduced motion artifacts. The IQ slightly degraded (1.3%) with changes in the studied beam collimations. Patient motion exhibited negative effects (within 7%) on the IQ. Among all features across all imaging conditions studies, compactness2 and elongation showed the largest (-26.5%, 7.8%) and smallest (-0.8%, 2.7%) relative bias and variability. The radiomics results were robust across the motion profiles studied. Conclusions: While high pitch and large beam collimations can negatively affect the quality of CT images, they are desirable for fast imaging. Further, our results showed no major adverse effects in morphology quantification of lung lesions with the increase in pitch or beam collimation. VCTs, such as the one demonstrated in this study, represent a viable methodology for experiments in CT. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:17
相关论文
共 39 条
[1]  
Abadi E, 2018, MED PHYS, V45, pE638
[2]   Virtual clinical trials in medical imaging: a review [J].
Abadi, Ehsan ;
Segars, William P. ;
Tsui, Benjamin M. W. ;
Kinahan, Paul E. ;
Bottenus, Nick ;
Frangi, Alejandro F. ;
Maidment, Andrew ;
Lo, Joseph ;
Samei, Ehsan .
JOURNAL OF MEDICAL IMAGING, 2020, 7 (04)
[3]   Development of a scanner-specific simulation framework for photon-counting computed tomography [J].
Abadi, Ehsan ;
Harrawood, Brian ;
Rajagopal, Jayasai R. ;
Sharma, Shobhit ;
Kapadia, Anuj ;
Segars, William Paul ;
Stierstorfer, Karl ;
Sedlmair, Martin ;
Jones, Elizabeth ;
Samei, Ehsan .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05)
[4]   Modeling "Textured" Bones in Virtual Human Phantoms [J].
Abadi, Ehsan ;
Segars, William P. ;
Sturgeon, Gregory M. ;
Harrawood, Brian ;
Kapadia, Anuj ;
Samei, Ehsan .
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (01) :47-53
[5]   DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography [J].
Abadi, Ehsan ;
Harrawood, Brian ;
Sharma, Shobhit ;
Kapadia, Anuj ;
Segars, William P. ;
Samei, Ehsan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) :1457-1465
[6]   Modeling Lung Architecture in the XCAT Series of Phantoms: Physiologically Based Airways, Arteries and Veins [J].
Abadi, Ehsan ;
Segars, William P. ;
Sturgeon, Gregory M. ;
Roos, Justus E. ;
Ravin, Carl E. ;
Samei, Ehsan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (03) :693-702
[7]   Airways, vasculature, and interstitial tissue: anatomically-informed computational modeling of human lungs for virtual clinical trials [J].
Abadi, Ehsan ;
Sturgeon, Gregory M. ;
Agasthya, Greeshma ;
Harrawood, Brian ;
Hoeschen, Christoph ;
Kapadia, Anuj ;
Segars, W. Paul ;
Samei, Ehsan .
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
[8]   Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach [J].
Aerts, Hugo J. W. L. ;
Velazquez, Emmanuel Rios ;
Leijenaar, Ralph T. H. ;
Parmar, Chintan ;
Grossmann, Patrick ;
Cavalho, Sara ;
Bussink, Johan ;
Monshouwer, Rene ;
Haibe-Kains, Benjamin ;
Rietveld, Derek ;
Hoebers, Frank ;
Rietbergen, Michelle M. ;
Leemans, C. Rene ;
Dekker, Andre ;
Quackenbush, John ;
Gillies, Robert J. ;
Lambin, Philippe .
NATURE COMMUNICATIONS, 2014, 5
[9]   Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit [J].
Badal, Andreu ;
Badano, Aldo .
MEDICAL PHYSICS, 2009, 36 (11) :4878-4880
[10]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691